Changes for page SN50v3-LB/LS -- LoRaWAN Sensor Node User Manual
Last modified by Bei Jinggeng on 2025/01/10 15:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -16,7 +16,6 @@ 16 16 17 17 == 1.1 What is SN50v3-LB LoRaWAN Generic Node == 18 18 19 - 20 20 (% style="color:blue" %)**SN50V3-LB **(%%)LoRaWAN Sensor Node is a Long Range LoRa Sensor Node. It is designed for outdoor use and powered by (% style="color:blue" %)** 8500mA Li/SOCl2 battery**(%%) for long term use.SN50V3-LB is designed to facilitate developers to quickly deploy industrial level LoRa and IoT solutions. It help users to turn the idea into a practical application and make the Internet of Things a reality. It is easy to program, create and connect your things everywhere. 21 21 22 22 ... ... @@ -656,7 +656,7 @@ 656 656 657 657 ==== 2.3.3.2 Temperature (DS18B20) ==== 658 658 659 -If there is a DS18B20 connected to P C13 pin. The temperature will be uploaded in the payload.658 +If there is a DS18B20 connected to PB3 pin. The temperature will be uploaded in the payload. 660 660 661 661 More DS18B20 can check the [[3 DS18B20 mode>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/#2.3.4MOD3D4283xDS18B2029]] 662 662 ... ... @@ -685,8 +685,6 @@ 685 685 When the digital interrupt pin is set to AT+INTMODx=0, this pin is used as a digital input pin. 686 686 687 687 **Note:**The maximum voltage input supports 3.6V. 688 - 689 - 690 690 ))) 691 691 692 692 ==== 2.3.3.4 Analogue Digital Converter (ADC) ==== ... ... @@ -699,7 +699,6 @@ 699 699 700 700 **Note:**If the ADC type sensor needs to be powered by SN50_v3, it is recommended to use +5V to control its switch.Only sensors with low power consumption can be powered with VDD. 701 701 702 - 703 703 ==== 2.3.3.5 Digital Interrupt ==== 704 704 705 705 Digital Interrupt refers to pin PA8, and there are different trigger methods. When there is a trigger, the SN50v3 will send a packet to the server. ... ... @@ -853,8 +853,6 @@ 853 853 * 7: MOD8 854 854 * 8: MOD9 855 855 856 -== == 857 - 858 858 == 2.4 Payload Decoder file == 859 859 860 860 ... ... @@ -931,8 +931,8 @@ 931 931 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 932 932 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 933 933 934 -=== === 935 935 929 + 936 936 === 3.3.2 Get Device Status === 937 937 938 938 Send a LoRaWAN downlink to ask the device to send its status. ... ... @@ -980,8 +980,8 @@ 980 980 * Example 3: Downlink Payload: 06000102 **~-~-->** AT+INTMOD2=2 981 981 * Example 4: Downlink Payload: 06000201 **~-~-->** AT+INTMOD3=1 982 982 983 -=== === 984 984 978 + 985 985 === 3.3.4 Set Power Output Duration === 986 986 987 987 Control the output duration 5V . Before each sampling, device will ... ... @@ -1014,8 +1014,8 @@ 1014 1014 * Example 1: Downlink Payload: 070000 **~-~-->** AT+5VT=0 1015 1015 * Example 2: Downlink Payload: 0701F4 **~-~-->** AT+5VT=500 1016 1016 1017 -=== === 1018 1018 1012 + 1019 1019 === 3.3.5 Set Weighing parameters === 1020 1020 1021 1021 Feature: Working mode 5 is effective, weight initialization and weight factor setting of HX711. ... ... @@ -1040,8 +1040,8 @@ 1040 1040 * Example 2: Downlink Payload: 08020FA3 **~-~-->** AT+WEIGAP=400.3 1041 1041 * Example 3: Downlink Payload: 08020FA0 **~-~-->** AT+WEIGAP=400.0 1042 1042 1043 -=== === 1044 1044 1038 + 1045 1045 === 3.3.6 Set Digital pulse count value === 1046 1046 1047 1047 Feature: Set the pulse count value. ... ... @@ -1064,8 +1064,8 @@ 1064 1064 * Example 1: Downlink Payload: 090100000000 **~-~-->** AT+SETCNT=1,0 1065 1065 * Example 2: Downlink Payload: 0902000003E8 **~-~-->** AT+SETCNT=2,1000 1066 1066 1067 -=== === 1068 1068 1062 + 1069 1069 === 3.3.7 Set Workmode === 1070 1070 1071 1071 Feature: Switch working mode. ... ... @@ -1090,8 +1090,8 @@ 1090 1090 * Example 1: Downlink Payload: 0A01 **~-~-->** AT+MOD=1 1091 1091 * Example 2: Downlink Payload: 0A04 **~-~-->** AT+MOD=4 1092 1092 1093 -= = 1094 1094 1088 + 1095 1095 = 4. Battery & Power Consumption = 1096 1096 1097 1097 ... ... @@ -1165,4 +1165,4 @@ 1165 1165 1166 1166 1167 1167 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1168 -* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.c c>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.cc]]1162 +* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]