From version < 43.2 >
edited by Xiaoling
on 2023/05/16 13:39
To version < 41.2 >
edited by Xiaoling
on 2023/05/15 13:56
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -16,7 +16,6 @@
16 16  
17 17  == 1.1 What is SN50v3-LB LoRaWAN Generic Node ==
18 18  
19 -
20 20  (% style="color:blue" %)**SN50V3-LB **(%%)LoRaWAN Sensor Node is a Long Range LoRa Sensor Node. It is designed for outdoor use and powered by (% style="color:blue" %)** 8500mA Li/SOCl2 battery**(%%) for long term use.SN50V3-LB is designed to facilitate developers to quickly deploy industrial level LoRa and IoT solutions. It help users to turn the idea into a practical application and make the Internet of Things a reality. It is easy to program, create and connect your things everywhere.
21 21  
22 22  
... ... @@ -656,7 +656,7 @@
656 656  
657 657  ==== 2.3.3.2  Temperature (DS18B20) ====
658 658  
659 -If there is a DS18B20 connected to PC13 pin. The temperature will be uploaded in the payload.
658 +If there is a DS18B20 connected to PB3 pin. The temperature will be uploaded in the payload.
660 660  
661 661  More DS18B20 can check the [[3 DS18B20 mode>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/#2.3.4MOD3D4283xDS18B2029]]
662 662  
... ... @@ -685,8 +685,6 @@
685 685  When the digital interrupt pin is set to AT+INTMODx=0, this pin is used as a digital input pin.
686 686  
687 687  **Note:**The maximum voltage input supports 3.6V.
688 -
689 -
690 690  )))
691 691  
692 692  ==== 2.3.3.4  Analogue Digital Converter (ADC) ====
... ... @@ -699,7 +699,6 @@
699 699  
700 700  **Note:**If the ADC type sensor needs to be powered by SN50_v3, it is recommended to use +5V to control its switch.Only sensors with low power consumption can be powered with VDD.
701 701  
702 -
703 703  ==== 2.3.3.5 Digital Interrupt ====
704 704  
705 705  Digital Interrupt refers to pin PA8, and there are different trigger methods. When there is a trigger, the SN50v3 will send a packet to the server.
... ... @@ -853,8 +853,6 @@
853 853  * 7: MOD8
854 854  * 8: MOD9
855 855  
856 -== ==
857 -
858 858  == 2.4 Payload Decoder file ==
859 859  
860 860  
... ... @@ -1165,4 +1165,4 @@
1165 1165  
1166 1166  
1167 1167  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1168 -* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.cc>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.cc]]
1162 +* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0