Changes for page SN50v3-LB/LS -- LoRaWAN Sensor Node User Manual
Last modified by Bei Jinggeng on 2025/01/10 15:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -295,17 +295,22 @@ 295 295 In this mode, uplink payload includes in total 11 bytes. Uplink packets use FPORT=2. 296 296 297 297 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 298 -|(% style=" width:50px;background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|(% style="width:20px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:100px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:35px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:90px;background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="width:120px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:90px;background-color:#D9E2F3;color:#0070C0" %)**2**298 +|(% style="background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:191px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:78px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:216px;background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="width:308px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:154px;background-color:#D9E2F3;color:#0070C0" %)**2** 299 299 |**Value**|Bat|(% style="width:191px" %)((( 300 -Temperature(DS18B20)(PC13) 300 +Temperature(DS18B20) 301 +(PC13) 301 301 )))|(% style="width:78px" %)((( 302 -ADC(PA4) 303 +ADC 304 +(PA4) 303 303 )))|(% style="width:216px" %)((( 304 -Digital in(PB15)&Digital Interrupt(PA8) 306 +Digital in(PB15) & 307 +Digital Interrupt(PA8) 305 305 )))|(% style="width:308px" %)((( 306 -Temperature(SHT20 or SHT31 or BH1750 Illumination Sensor) 309 +Temperature 310 +(SHT20 or SHT31 or BH1750 Illumination Sensor) 307 307 )))|(% style="width:154px" %)((( 308 -Humidity(SHT20 or SHT31) 312 +Humidity 313 +(SHT20 or SHT31) 309 309 ))) 310 310 311 311 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220627150949-6.png?rev=1.1||alt="image-20220627150949-6.png"]] ... ... @@ -315,17 +315,22 @@ 315 315 316 316 This mode is target to measure the distance. The payload of this mode is totally 11 bytes. The 8^^th^^ and 9^^th^^ bytes is for the distance. 317 317 318 -(% border="1" cellspacing="4" style="background-color:#f2f2f2;width:520px" %)319 -| (% style="width:40px;background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|(% style="width:40px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:110px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:40px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:110px;background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="width:140px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:40px;background-color:#D9E2F3;color:#0070C0" %)**2**323 +(% style="width:1011px" %) 324 +|**Size(bytes)**|**2**|(% style="width:196px" %)**2**|(% style="width:87px" %)**2**|(% style="width:189px" %)**1**|(% style="width:208px" %)**2**|(% style="width:117px" %)**2** 320 320 |**Value**|BAT|(% style="width:196px" %)((( 321 -Temperature(DS18B20)(PC13) 326 +Temperature(DS18B20) 327 +(PC13) 322 322 )))|(% style="width:87px" %)((( 323 -ADC(PA4) 329 +ADC 330 +(PA4) 324 324 )))|(% style="width:189px" %)((( 325 -Digital in(PB15) & Digital Interrupt(PA8) 332 +Digital in(PB15) & 333 +Digital Interrupt(PA8) 326 326 )))|(% style="width:208px" %)((( 327 -Distance measure by:1) LIDAR-Lite V3HP 328 -Or 2) Ultrasonic Sensor 335 +Distance measure by: 336 +1) LIDAR-Lite V3HP 337 +Or 338 +2) Ultrasonic Sensor 329 329 )))|(% style="width:117px" %)Reserved 330 330 331 331 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/1656324539647-568.png?rev=1.1||alt="1656324539647-568.png"]] ... ... @@ -766,7 +766,7 @@ 766 766 767 767 The 5V output time can be controlled by AT Command. 768 768 769 - (% style="color:blue" %)**AT+5VT=1000**779 +**AT+5VT=1000** 770 770 771 771 Means set 5V valid time to have 1000ms. So the real 5V output will actually have 1000ms + sampling time for other sensors. 772 772 ... ... @@ -801,8 +801,8 @@ 801 801 * 7: MOD8 802 802 * 8: MOD9 803 803 814 +== == 804 804 805 - 806 806 == 2.4 Payload Decoder file == 807 807 808 808 ... ... @@ -879,8 +879,8 @@ 879 879 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 880 880 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 881 881 892 +=== === 882 882 883 - 884 884 === 3.3.2 Get Device Status === 885 885 886 886 Send a LoRaWAN downlink to ask the device to send its status. ... ... @@ -928,8 +928,8 @@ 928 928 * Example 3: Downlink Payload: 06000102 **~-~-->** AT+INTMOD2=2 929 929 * Example 4: Downlink Payload: 06000201 **~-~-->** AT+INTMOD3=1 930 930 941 +=== === 931 931 932 - 933 933 === 3.3.4 Set Power Output Duration === 934 934 935 935 Control the output duration 5V . Before each sampling, device will ... ... @@ -946,6 +946,7 @@ 946 946 |=(% style="width: 154px;background-color:#D9E2F3" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3" %)**Function**|=(% style="width: 157px;background-color:#D9E2F3" %)**Response** 947 947 |(% style="width:154px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:157px" %)((( 948 948 500(default) 959 + 949 949 OK 950 950 ))) 951 951 |(% style="width:154px" %)AT+5VT=1000|(% style="width:196px" %)((( ... ... @@ -961,8 +961,8 @@ 961 961 * Example 1: Downlink Payload: 070000 **~-~-->** AT+5VT=0 962 962 * Example 2: Downlink Payload: 0701F4 **~-~-->** AT+5VT=500 963 963 975 +=== === 964 964 965 - 966 966 === 3.3.5 Set Weighing parameters === 967 967 968 968 Feature: Working mode 5 is effective, weight initialization and weight factor setting of HX711. ... ... @@ -987,8 +987,8 @@ 987 987 * Example 2: Downlink Payload: 08020FA3 **~-~-->** AT+WEIGAP=400.3 988 988 * Example 3: Downlink Payload: 08020FA0 **~-~-->** AT+WEIGAP=400.0 989 989 1001 +=== === 990 990 991 - 992 992 === 3.3.6 Set Digital pulse count value === 993 993 994 994 Feature: Set the pulse count value. ... ... @@ -1011,8 +1011,8 @@ 1011 1011 * Example 1: Downlink Payload: 090100000000 **~-~-->** AT+SETCNT=1,0 1012 1012 * Example 2: Downlink Payload: 0902000003E8 **~-~-->** AT+SETCNT=2,1000 1013 1013 1025 +=== === 1014 1014 1015 - 1016 1016 === 3.3.7 Set Workmode === 1017 1017 1018 1018 Feature: Switch working mode. ... ... @@ -1026,6 +1026,7 @@ 1026 1026 ))) 1027 1027 |(% style="width:154px" %)AT+MOD=4|(% style="width:196px" %)Set the working mode to 3DS18B20s.|(% style="width:157px" %)((( 1028 1028 OK 1040 + 1029 1029 Attention:Take effect after ATZ 1030 1030 ))) 1031 1031 ... ... @@ -1036,8 +1036,8 @@ 1036 1036 * Example 1: Downlink Payload: 0A01 **~-~-->** AT+MOD=1 1037 1037 * Example 2: Downlink Payload: 0A04 **~-~-->** AT+MOD=4 1038 1038 1051 += = 1039 1039 1040 - 1041 1041 = 4. Battery & Power Consumption = 1042 1042 1043 1043 ... ... @@ -1111,5 +1111,4 @@ 1111 1111 1112 1112 1113 1113 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1114 - 1115 1115 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.cc>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.cc]]