Changes for page SN50v3-LB/LS -- LoRaWAN Sensor Node User Manual
Last modified by Bei Jinggeng on 2025/01/10 15:51
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Saxer1 +XWiki.Xiaoling - Content
-
... ... @@ -16,18 +16,15 @@ 16 16 17 17 == 1.1 What is SN50v3-LB LoRaWAN Generic Node == 18 18 19 + 19 19 (% style="color:blue" %)**SN50V3-LB **(%%)LoRaWAN Sensor Node is a Long Range LoRa Sensor Node. It is designed for outdoor use and powered by (% style="color:blue" %)** 8500mA Li/SOCl2 battery**(%%) for long term use.SN50V3-LB is designed to facilitate developers to quickly deploy industrial level LoRa and IoT solutions. It help users to turn the idea into a practical application and make the Internet of Things a reality. It is easy to program, create and connect your things everywhere. 20 20 21 - 22 22 (% style="color:blue" %)**SN50V3-LB wireless part**(%%) is based on SX1262 allows the user to send data and reach extremely long ranges at low data-rates.It provides ultra-long range spread spectrum communication and high interference immunity whilst minimising current consumption.It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on. 23 23 24 - 25 25 (% style="color:blue" %)**SN50V3-LB **(%%)has a powerful 48Mhz ARM microcontroller with 256KB flash and 64KB RAM. It has multiplex I/O pins to connect to different sensors. 26 26 27 - 28 28 (% style="color:blue" %)**SN50V3-LB**(%%) has a built-in BLE module, user can configure the sensor remotely via Mobile Phone. It also support OTA upgrade via private LoRa protocol for easy maintaining. 29 29 30 - 31 31 SN50V3-LB is the 3^^rd^^ generation of LSN50 series generic sensor node from Dragino. It is an (% style="color:blue" %)**open source project**(%%) and has a mature LoRaWAN stack and application software. User can use the pre-load software for their IoT projects or easily customize the software for different requirements. 32 32 33 33 ... ... @@ -45,6 +45,7 @@ 45 45 46 46 == 1.3 Specification == 47 47 45 + 48 48 (% style="color:#037691" %)**Common DC Characteristics:** 49 49 50 50 * Supply Voltage: built in 8500mAh Li-SOCI2 battery , 2.5v ~~ 3.6v ... ... @@ -81,6 +81,7 @@ 81 81 82 82 == 1.4 Sleep mode and working mode == 83 83 82 + 84 84 (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life. 85 85 86 86 (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode. ... ... @@ -138,6 +138,7 @@ 138 138 139 139 == Hole Option == 140 140 140 + 141 141 SN50v3-LB has different hole size options for different size sensor cable. The options provided are M12, M16 and M20. The definition is as below: 142 142 143 143 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220627104757-1.png?rev=1.1||alt="image-20220627104757-1.png"]] ... ... @@ -291,31 +291,25 @@ 291 291 292 292 ==== 2.3.2.1 MOD~=1 (Default Mode) ==== 293 293 294 + 294 294 In this mode, uplink payload includes in total 11 bytes. Uplink packets use FPORT=2. 295 295 296 -(% style="width: 1110px" %)297 -|**Size(bytes)**|**2**|(% style="width:191px" %)**2**|(% style="width:78px" %)**2**|(% style="width:216px" %)**1**|(% style="width:308px" %)**2**|(% style="width:154px" %)**2** 297 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 298 +|(% style="background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:191px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:78px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:216px;background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="width:308px;background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="width:154px;background-color:#D9E2F3;color:#0070C0" %)**2** 298 298 |**Value**|Bat|(% style="width:191px" %)((( 299 299 Temperature(DS18B20) 300 - 301 301 (PC13) 302 302 )))|(% style="width:78px" %)((( 303 303 ADC 304 - 305 305 (PA4) 306 306 )))|(% style="width:216px" %)((( 307 307 Digital in(PB15) & 308 - 309 -Digital Interrupt(PA8) 310 - 311 - 307 +Digital Interrupt(PA8) 312 312 )))|(% style="width:308px" %)((( 313 313 Temperature 314 - 315 315 (SHT20 or SHT31 or BH1750 Illumination Sensor) 316 316 )))|(% style="width:154px" %)((( 317 317 Humidity 318 - 319 319 (SHT20 or SHT31) 320 320 ))) 321 321 ... ... @@ -330,15 +330,12 @@ 330 330 |**Size(bytes)**|**2**|(% style="width:196px" %)**2**|(% style="width:87px" %)**2**|(% style="width:189px" %)**1**|(% style="width:208px" %)**2**|(% style="width:117px" %)**2** 331 331 |**Value**|BAT|(% style="width:196px" %)((( 332 332 Temperature(DS18B20) 333 - 334 334 (PC13) 335 335 )))|(% style="width:87px" %)((( 336 336 ADC 337 - 338 338 (PA4) 339 339 )))|(% style="width:189px" %)((( 340 340 Digital in(PB15) & 341 - 342 342 Digital Interrupt(PA8) 343 343 )))|(% style="width:208px" %)((( 344 344 Distance measure by: ... ... @@ -365,15 +365,12 @@ 365 365 |**Size(bytes)**|**2**|(% style="width:183px" %)**2**|(% style="width:173px" %)**1**|(% style="width:84px" %)**2**|(% style="width:323px" %)**2**|(% style="width:188px" %)**2** 366 366 |**Value**|BAT|(% style="width:183px" %)((( 367 367 Temperature(DS18B20) 368 - 369 369 (PC13) 370 370 )))|(% style="width:173px" %)((( 371 371 Digital in(PB15) & 372 - 373 373 Digital Interrupt(PA8) 374 374 )))|(% style="width:84px" %)((( 375 375 ADC 376 - 377 377 (PA4) 378 378 )))|(% style="width:323px" %)((( 379 379 Distance measure by:1)TF-Mini plus LiDAR ... ... @@ -406,25 +406,20 @@ 406 406 )))|=(% style="width: 68px;" %)**2**|=(% style="width: 75px;" %)**2**|=**2**|=**1**|=(% style="width: 304px;" %)2|=(% style="width: 163px;" %)2|=(% style="width: 53px;" %)1 407 407 |**Value**|(% style="width:68px" %)((( 408 408 ADC1 409 - 410 410 (PA4) 411 411 )))|(% style="width:75px" %)((( 412 412 ADC2 413 - 414 414 (PA5) 415 415 )))|((( 416 416 ADC3 417 - 418 418 (PA8) 419 419 )))|((( 420 420 Digital Interrupt(PB15) 421 421 )))|(% style="width:304px" %)((( 422 422 Temperature 423 - 424 424 (SHT20 or SHT31 or BH1750 Illumination Sensor) 425 425 )))|(% style="width:163px" %)((( 426 426 Humidity 427 - 428 428 (SHT20 or SHT31) 429 429 )))|(% style="width:53px" %)Bat 430 430 ... ... @@ -443,11 +443,9 @@ 443 443 (PC13) 444 444 )))|(% style="width:82px" %)((( 445 445 ADC 446 - 447 447 (PA4) 448 448 )))|(% style="width:210px" %)((( 449 449 Digital in(PB15) & 450 - 451 451 Digital Interrupt(PA8) 452 452 )))|(% style="width:191px" %)Temperature2(DS18B20) 453 453 (PB9)|(% style="width:183px" %)Temperature3(DS18B20) ... ... @@ -484,17 +484,12 @@ 484 484 )))|=**2**|=(% style="width: 193px;" %)**2**|=(% style="width: 85px;" %)**2**|=(% style="width: 186px;" %)**1**|=(% style="width: 100px;" %)**4** 485 485 |**Value**|BAT|(% style="width:193px" %)((( 486 486 Temperature(DS18B20) 487 - 488 488 (PC13) 489 - 490 - 491 491 )))|(% style="width:85px" %)((( 492 492 ADC 493 - 494 494 (PA4) 495 495 )))|(% style="width:186px" %)((( 496 496 Digital in(PB15) & 497 - 498 498 Digital Interrupt(PA8) 499 499 )))|(% style="width:100px" %)Weight 500 500 ... ... @@ -519,15 +519,12 @@ 519 519 (PC13) 520 520 )))|(% style="width:108px" %)((( 521 521 ADC 522 - 523 523 (PA4) 524 524 )))|(% style="width:126px" %)((( 525 525 Digital in 526 - 527 527 (PB15) 528 528 )))|(% style="width:145px" %)((( 529 529 Count 530 - 531 531 (PA8) 532 532 ))) 533 533 ... ... @@ -542,11 +542,9 @@ 542 542 )))|=**2**|=(% style="width: 188px;" %)**2**|=(% style="width: 83px;" %)**2**|=(% style="width: 184px;" %)**1**|=(% style="width: 186px;" %)**1**|=(% style="width: 197px;" %)1|=(% style="width: 100px;" %)2 543 543 |**Value**|BAT|(% style="width:188px" %)((( 544 544 Temperature(DS18B20) 545 - 546 546 (PC13) 547 547 )))|(% style="width:83px" %)((( 548 548 ADC 549 - 550 550 (PA5) 551 551 )))|(% style="width:184px" %)((( 552 552 Digital Interrupt1(PA8) ... ... @@ -562,21 +562,17 @@ 562 562 )))|=**2**|=(% style="width: 207px;" %)**2**|=(% style="width: 94px;" %)**2**|=(% style="width: 198px;" %)**1**|=(% style="width: 84px;" %)**2**|=(% style="width: 82px;" %)2 563 563 |**Value**|BAT|(% style="width:207px" %)((( 564 564 Temperature(DS18B20) 565 - 566 566 (PC13) 567 567 )))|(% style="width:94px" %)((( 568 568 ADC1 569 - 570 570 (PA4) 571 571 )))|(% style="width:198px" %)((( 572 572 Digital Interrupt(PB15) 573 573 )))|(% style="width:84px" %)((( 574 574 ADC2 575 - 576 576 (PA5) 577 577 )))|(% style="width:82px" %)((( 578 578 ADC3 579 - 580 580 (PA8) 581 581 ))) 582 582 ... ... @@ -591,27 +591,21 @@ 591 591 )))|=**2**|=**2**|=**2**|=**1**|=(% style="width: 193px;" %)**2**|=(% style="width: 78px;" %)4|=(% style="width: 78px;" %)4 592 592 |**Value**|BAT|((( 593 593 Temperature1(DS18B20) 594 - 595 595 (PC13) 596 596 )))|((( 597 597 Temperature2(DS18B20) 598 - 599 599 (PB9) 600 600 )))|((( 601 601 Digital Interrupt 602 - 603 603 (PB15) 604 604 )))|(% style="width:193px" %)((( 605 605 Temperature3(DS18B20) 606 - 607 607 (PB8) 608 608 )))|(% style="width:78px" %)((( 609 609 Count1 610 - 611 611 (PA8) 612 612 )))|(% style="width:78px" %)((( 613 613 Count2 614 - 615 615 (PA4) 616 616 ))) 617 617 ... ... @@ -683,9 +683,7 @@ 683 683 ((( 684 684 When the digital interrupt pin is set to AT+INTMODx=0, this pin is used as a digital input pin. 685 685 686 -**Note:**The maximum voltage input supports 3.6V. 687 - 688 - 647 +(% style="color:red" %)**Note:**The maximum voltage input supports 3.6V. 689 689 ))) 690 690 691 691 ==== 2.3.3.4 Analogue Digital Converter (ADC) ==== ... ... @@ -696,7 +696,7 @@ 696 696 697 697 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220628150112-1.png?width=285&height=241&rev=1.1||alt="image-20220628150112-1.png" height="241" width="285"]] 698 698 699 -**Note:**If the ADC type sensor needs to be powered by SN50_v3, it is recommended to use +5V to control its switch.Only sensors with low power consumption can be powered with VDD. 658 +(% style="color:red" %)**Note:**If the ADC type sensor needs to be powered by SN50_v3, it is recommended to use +5V to control its switch.Only sensors with low power consumption can be powered with VDD. 700 700 701 701 702 702 ==== 2.3.3.5 Digital Interrupt ==== ... ... @@ -703,11 +703,11 @@ 703 703 704 704 Digital Interrupt refers to pin PA8, and there are different trigger methods. When there is a trigger, the SN50v3 will send a packet to the server. 705 705 706 -**~ Interrupt connection method:** 665 +(% style="color:blue" %)**~ Interrupt connection method:** 707 707 708 708 [[image:image-20230513105351-5.png||height="147" width="485"]] 709 709 710 -**Example to use with door sensor :** 669 +(% style="color:blue" %)**Example to use with door sensor :** 711 711 712 712 The door sensor is shown at right. It is a two wire magnetic contact switch used for detecting the open/close status of doors or windows. 713 713 ... ... @@ -715,7 +715,7 @@ 715 715 716 716 When the two pieces are close to each other, the 2 wire output will be short or open (depending on the type), while if the two pieces are away from each other, the 2 wire output will be the opposite status. So we can use SN50_v3 interrupt interface to detect the status for the door or window. 717 717 718 -**~ Below is the installation example:** 677 +(% style="color:blue" %)**~ Below is the installation example:** 719 719 720 720 Fix one piece of the magnetic sensor to the door and connect the two pins to SN50_v3 as follows: 721 721 ... ... @@ -740,7 +740,7 @@ 740 740 741 741 The command is: 742 742 743 -**AT+INTMOD1=1 702 +(% style="color:blue" %)**AT+INTMOD1=1 ** (%%) ~/~/(more info about INMOD please refer** **[[**AT Command Manual**>>url:http://www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/&file=DRAGINO_LSN50_AT_Commands_v1.5.1.pdf]]**. **) 744 744 745 745 Below shows some screen captures in TTN V3: 746 746 ... ... @@ -852,7 +852,6 @@ 852 852 * 7: MOD8 853 853 * 8: MOD9 854 854 855 -(% class="wikigeneratedid" %) 856 856 == == 857 857 858 858 == 2.4 Payload Decoder file == ... ... @@ -931,7 +931,6 @@ 931 931 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 932 932 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 933 933 934 -(% class="wikigeneratedid" %) 935 935 === === 936 936 937 937 === 3.3.2 Get Device Status === ... ... @@ -981,7 +981,6 @@ 981 981 * Example 3: Downlink Payload: 06000102 **~-~-->** AT+INTMOD2=2 982 982 * Example 4: Downlink Payload: 06000201 **~-~-->** AT+INTMOD3=1 983 983 984 -(% class="wikigeneratedid" %) 985 985 === === 986 986 987 987 === 3.3.4 Set Power Output Duration === ... ... @@ -1016,7 +1016,6 @@ 1016 1016 * Example 1: Downlink Payload: 070000 **~-~-->** AT+5VT=0 1017 1017 * Example 2: Downlink Payload: 0701F4 **~-~-->** AT+5VT=500 1018 1018 1019 -(% class="wikigeneratedid" %) 1020 1020 === === 1021 1021 1022 1022 === 3.3.5 Set Weighing parameters === ... ... @@ -1043,7 +1043,6 @@ 1043 1043 * Example 2: Downlink Payload: 08020FA3 **~-~-->** AT+WEIGAP=400.3 1044 1044 * Example 3: Downlink Payload: 08020FA0 **~-~-->** AT+WEIGAP=400.0 1045 1045 1046 -(% class="wikigeneratedid" %) 1047 1047 === === 1048 1048 1049 1049 === 3.3.6 Set Digital pulse count value === ... ... @@ -1068,7 +1068,6 @@ 1068 1068 * Example 1: Downlink Payload: 090100000000 **~-~-->** AT+SETCNT=1,0 1069 1069 * Example 2: Downlink Payload: 0902000003E8 **~-~-->** AT+SETCNT=2,1000 1070 1070 1071 -(% class="wikigeneratedid" %) 1072 1072 === === 1073 1073 1074 1074 === 3.3.7 Set Workmode === ... ... @@ -1095,7 +1095,6 @@ 1095 1095 * Example 1: Downlink Payload: 0A01 **~-~-->** AT+MOD=1 1096 1096 * Example 2: Downlink Payload: 0A04 **~-~-->** AT+MOD=4 1097 1097 1098 -(% class="wikigeneratedid" %) 1099 1099 = = 1100 1100 1101 1101 = 4. Battery & Power Consumption =