Changes for page SN50v3-LB/LS -- LoRaWAN Sensor Node User Manual
Last modified by Bei Jinggeng on 2025/01/10 15:51
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Saxer1 +XWiki.Xiaoling - Content
-
... ... @@ -655,7 +655,7 @@ 655 655 656 656 ==== 2.3.3.2 Temperature (DS18B20) ==== 657 657 658 -If there is a DS18B20 connected to P C13 pin. The temperature will be uploaded in the payload.658 +If there is a DS18B20 connected to PB3 pin. The temperature will be uploaded in the payload. 659 659 660 660 More DS18B20 can check the [[3 DS18B20 mode>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/#2.3.4MOD3D4283xDS18B2029]] 661 661 ... ... @@ -684,8 +684,6 @@ 684 684 When the digital interrupt pin is set to AT+INTMODx=0, this pin is used as a digital input pin. 685 685 686 686 **Note:**The maximum voltage input supports 3.6V. 687 - 688 - 689 689 ))) 690 690 691 691 ==== 2.3.3.4 Analogue Digital Converter (ADC) ==== ... ... @@ -698,7 +698,6 @@ 698 698 699 699 **Note:**If the ADC type sensor needs to be powered by SN50_v3, it is recommended to use +5V to control its switch.Only sensors with low power consumption can be powered with VDD. 700 700 701 - 702 702 ==== 2.3.3.5 Digital Interrupt ==== 703 703 704 704 Digital Interrupt refers to pin PA8, and there are different trigger methods. When there is a trigger, the SN50v3 will send a packet to the server. ... ... @@ -852,9 +852,6 @@ 852 852 * 7: MOD8 853 853 * 8: MOD9 854 854 855 -(% class="wikigeneratedid" %) 856 -== == 857 - 858 858 == 2.4 Payload Decoder file == 859 859 860 860 ... ... @@ -931,9 +931,8 @@ 931 931 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 932 932 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 933 933 934 -(% class="wikigeneratedid" %) 935 -=== === 936 936 929 + 937 937 === 3.3.2 Get Device Status === 938 938 939 939 Send a LoRaWAN downlink to ask the device to send its status. ... ... @@ -981,9 +981,8 @@ 981 981 * Example 3: Downlink Payload: 06000102 **~-~-->** AT+INTMOD2=2 982 982 * Example 4: Downlink Payload: 06000201 **~-~-->** AT+INTMOD3=1 983 983 984 -(% class="wikigeneratedid" %) 985 -=== === 986 986 978 + 987 987 === 3.3.4 Set Power Output Duration === 988 988 989 989 Control the output duration 5V . Before each sampling, device will ... ... @@ -1016,9 +1016,8 @@ 1016 1016 * Example 1: Downlink Payload: 070000 **~-~-->** AT+5VT=0 1017 1017 * Example 2: Downlink Payload: 0701F4 **~-~-->** AT+5VT=500 1018 1018 1019 -(% class="wikigeneratedid" %) 1020 -=== === 1021 1021 1012 + 1022 1022 === 3.3.5 Set Weighing parameters === 1023 1023 1024 1024 Feature: Working mode 5 is effective, weight initialization and weight factor setting of HX711. ... ... @@ -1043,9 +1043,8 @@ 1043 1043 * Example 2: Downlink Payload: 08020FA3 **~-~-->** AT+WEIGAP=400.3 1044 1044 * Example 3: Downlink Payload: 08020FA0 **~-~-->** AT+WEIGAP=400.0 1045 1045 1046 -(% class="wikigeneratedid" %) 1047 -=== === 1048 1048 1038 + 1049 1049 === 3.3.6 Set Digital pulse count value === 1050 1050 1051 1051 Feature: Set the pulse count value. ... ... @@ -1068,9 +1068,8 @@ 1068 1068 * Example 1: Downlink Payload: 090100000000 **~-~-->** AT+SETCNT=1,0 1069 1069 * Example 2: Downlink Payload: 0902000003E8 **~-~-->** AT+SETCNT=2,1000 1070 1070 1071 -(% class="wikigeneratedid" %) 1072 -=== === 1073 1073 1062 + 1074 1074 === 3.3.7 Set Workmode === 1075 1075 1076 1076 Feature: Switch working mode. ... ... @@ -1095,9 +1095,8 @@ 1095 1095 * Example 1: Downlink Payload: 0A01 **~-~-->** AT+MOD=1 1096 1096 * Example 2: Downlink Payload: 0A04 **~-~-->** AT+MOD=4 1097 1097 1098 -(% class="wikigeneratedid" %) 1099 -= = 1100 1100 1088 + 1101 1101 = 4. Battery & Power Consumption = 1102 1102 1103 1103