<
From version < 42.1 >
edited by Saxer Lin
on 2023/05/16 11:27
To version < 43.2 >
edited by Xiaoling
on 2023/05/16 13:39
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Saxer
1 +XWiki.Xiaoling
Content
... ... @@ -16,6 +16,7 @@
16 16  
17 17  == 1.1 What is SN50v3-LB LoRaWAN Generic Node ==
18 18  
19 +
19 19  (% style="color:blue" %)**SN50V3-LB **(%%)LoRaWAN Sensor Node is a Long Range LoRa Sensor Node. It is designed for outdoor use and powered by (% style="color:blue" %)** 8500mA Li/SOCl2 battery**(%%) for long term use.SN50V3-LB is designed to facilitate developers to quickly deploy industrial level LoRa and IoT solutions. It help users to turn the idea into a practical application and make the Internet of Things a reality. It is easy to program, create and connect your things everywhere.
20 20  
21 21  
... ... @@ -684,6 +684,8 @@
684 684  When the digital interrupt pin is set to AT+INTMODx=0, this pin is used as a digital input pin.
685 685  
686 686  **Note:**The maximum voltage input supports 3.6V.
688 +
689 +
687 687  )))
688 688  
689 689  ==== 2.3.3.4  Analogue Digital Converter (ADC) ====
... ... @@ -696,6 +696,7 @@
696 696  
697 697  **Note:**If the ADC type sensor needs to be powered by SN50_v3, it is recommended to use +5V to control its switch.Only sensors with low power consumption can be powered with VDD.
698 698  
702 +
699 699  ==== 2.3.3.5 Digital Interrupt ====
700 700  
701 701  Digital Interrupt refers to pin PA8, and there are different trigger methods. When there is a trigger, the SN50v3 will send a packet to the server.
... ... @@ -849,6 +849,8 @@
849 849  * 7: MOD8
850 850  * 8: MOD9
851 851  
856 +== ==
857 +
852 852  == 2.4 Payload Decoder file ==
853 853  
854 854  
... ... @@ -925,6 +925,7 @@
925 925  * Example 1: Downlink Payload: 0100001E  ~/~/  Set Transmit Interval (TDC) = 30 seconds
926 926  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
927 927  
934 +=== ===
928 928  
929 929  === 3.3.2 Get Device Status ===
930 930  
... ... @@ -973,6 +973,7 @@
973 973  * Example 3: Downlink Payload: 06000102  **~-~-->**  AT+INTMOD2=2
974 974  * Example 4: Downlink Payload: 06000201  **~-~-->**  AT+INTMOD3=1
975 975  
983 +=== ===
976 976  
977 977  === 3.3.4 Set Power Output Duration ===
978 978  
... ... @@ -1006,6 +1006,7 @@
1006 1006  * Example 1: Downlink Payload: 070000  **~-~-->**  AT+5VT=0
1007 1007  * Example 2: Downlink Payload: 0701F4  **~-~-->**  AT+5VT=500
1008 1008  
1017 +=== ===
1009 1009  
1010 1010  === 3.3.5 Set Weighing parameters ===
1011 1011  
... ... @@ -1031,6 +1031,7 @@
1031 1031  * Example 2: Downlink Payload: 08020FA3  **~-~-->**  AT+WEIGAP=400.3
1032 1032  * Example 3: Downlink Payload: 08020FA0  **~-~-->**  AT+WEIGAP=400.0
1033 1033  
1043 +=== ===
1034 1034  
1035 1035  === 3.3.6 Set Digital pulse count value ===
1036 1036  
... ... @@ -1054,6 +1054,7 @@
1054 1054  * Example 1: Downlink Payload: 090100000000  **~-~-->**  AT+SETCNT=1,0
1055 1055  * Example 2: Downlink Payload: 0902000003E8  **~-~-->**  AT+SETCNT=2,1000
1056 1056  
1067 +=== ===
1057 1057  
1058 1058  === 3.3.7 Set Workmode ===
1059 1059  
... ... @@ -1079,6 +1079,7 @@
1079 1079  * Example 1: Downlink Payload: 0A01  **~-~-->**  AT+MOD=1
1080 1080  * Example 2: Downlink Payload: 0A04  **~-~-->**  AT+MOD=4
1081 1081  
1093 += =
1082 1082  
1083 1083  = 4. Battery & Power Consumption =
1084 1084  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0