Changes for page SN50v3-LB/LS -- LoRaWAN Sensor Node User Manual
Last modified by Xiaoling on 2025/06/12 15:06
From version 117.3
edited by Xiaoling
on 2025/03/29 09:07
on 2025/03/29 09:07
Change comment:
There is no comment for this version
To version 122.1
edited by Mengting Qiu
on 2025/04/02 11:17
on 2025/04/02 11:17
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.ting - Content
-
... ... @@ -781,7 +781,7 @@ 781 781 782 782 If payload is: FF3FH : (FF3F & 8000 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees. 783 783 784 - (FF3F & 8000:Judge whether the highest bit is 1, when the highest bit is 1, it is negative)784 +(FF3F & 8000:Judge whether the highest bit is 1, when the highest bit is 1, it is negative) 785 785 786 786 787 787 ==== 2.3.3.3 Digital Input ==== ... ... @@ -871,11 +871,34 @@ 871 871 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/1656379339508-835.png?rev=1.1||alt="1656379339508-835.png"]] 872 872 873 873 874 - In**MOD=1**, usercanusebyte 6 toseethe statusfordoor open or close. TTN V3decoder isas below:874 +(% style="color:blue" %)**Application in different modes:** 875 875 876 - door=(bytes[6]&0x80)?"CLOSE":"OPEN";876 +* In **MOD=1**, user can use byte 6 to see the status for door open or close. TTN V3 decoder is as below: 877 877 878 + door= (bytes[6] & 0x80)? "CLOSE":"OPEN"; 878 878 880 + 881 +* In **MOD=7**, there are three interrupt pins in effect. 882 + 883 +See the AT+INTMODx command explained to set the three pin interrupt modes. 884 + 885 +As you can see from the byte parsing table of pattern 7, the seventh byte of the original load is used to display the PA8 pin interrupt flag and status, the eighth byte of the original load is used to display the PA4 pin interrupt flag and status, and the ninth byte of the original load is used to display the PB15 pin interrupt flag and status. 886 + 887 +[[image:image-20250402103902-1.png]] 888 + 889 +TTN V3 decoder is as below: 890 + 891 +[[image:image-20250402104508-2.png||height="255" width="579"]] 892 + 893 +(% style="color:red" %)**Note: mode in decoding is sorted from 0, so it corresponds to the actual working mode AT+MOD=7.** 894 + 895 + 896 +(% style="color:#037691" %)**Interrupt flag: **(%%)"EXTI1/2/3_Trigger", indicates whether the uplink packet is generated by an interrupt on the PA8/PA4/PB15 pin. 897 + 898 + 899 +(% style="color:#037691" %)**Interrupt status: **(%%)"EXTI1/2/3_Status", Displays the status of the interrupt sensors connected to the PA4/PA8/PB15 interrupt pins when the packet is uplinked. 900 + 901 + 879 879 ==== 2.3.3.6 I2C Interface (SHT20 & SHT31) ==== 880 880 881 881 ... ... @@ -992,6 +992,9 @@ 992 992 a) If real-time control output is required, the SN50v3-LB/LS is already operating in class C and an external power supply must be used. 993 993 994 994 b) If the output duration is more than 30 seconds, better to use external power source. 1018 + 1019 + 1020 + 995 995 ))) 996 996 997 997 ==== 2.3.3.13 Working MOD ==== ... ... @@ -1146,6 +1146,7 @@ 1146 1146 * Downlink Payload: **06 00 01 02 **~/~/ Equal to AT+INTMOD2=2 1147 1147 * Downlink Payload: **06 00 02 03 **~/~/ Equal to AT+INTMOD3=3 1148 1148 1175 + 1149 1149 ==== 3.3.3.2 Since V1.3.4 firmware ==== 1150 1150 1151 1151 (% style="color:red" %)**Note: Since V1.3.4 firmware, the Interrupt function has added a new parameter to set the delay time, i.e. the state hold time.** ... ... @@ -1152,8 +1152,8 @@ 1152 1152 1153 1153 (% style="color:#037691" %)**AT Command:**(% style="color:blue" %)** **(% style="color:#4472c4" %)**AT+INTMODx=a,b** 1154 1154 1155 -(% border="1" cellspacing=" 4" style="background-color:#f2f2f2; width:420px" %)1156 -|=(% style="width: 116px; background-color: rgb(79, 129, 189); color: white;" %)**Parameter **|=(% style="width: 3 92px; background-color: rgb(79, 129, 189); color: white;" %)**Values and functions**1182 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:420px" %) 1183 +|=(% style="width: 116px; background-color: rgb(79, 129, 189); color: white;" %)**Parameter **|=(% style="width: 304px; background-color: rgb(79, 129, 189); color: white;" %)**Values and functions** 1157 1157 |(% style="width:116px" %)((( 1158 1158 1159 1159 ... ... @@ -1186,9 +1186,9 @@ 1186 1186 1187 1187 **Example:** 1188 1188 1189 -* AT+INTMOD1=0,0 ~/~/Disable the PA8 pin interrupt function 1190 -* AT+INTMOD2=2,1000 ~/~/Set the interrupt of the PA4 pin to be triggered by the falling edge, however, the interrupt will only be triggered if the low level state remains 1000ms 1191 -* AT+INTMOD3=3,2500 ~/~/Set the interrupt of the PB15 pin to be triggered by the rising edge, however, the interrupt will only be triggered if the high level state remains 2500ms 1216 +* AT+INTMOD1=0,0 ~/~/ Disable the PA8 pin interrupt function 1217 +* AT+INTMOD2=2,1000 ~/~/ Set the interrupt of the PA4 pin to be triggered by the falling edge, however, the interrupt will only be triggered if the low level state remains 1000ms 1218 +* AT+INTMOD3=3,2500 ~/~/ Set the interrupt of the PB15 pin to be triggered by the rising edge, however, the interrupt will only be triggered if the high level state remains 2500ms 1192 1192 1193 1193 (% style="color:#037691" %)**Downlink Command:**(% style="color:blue" %)** **(% style="color:#4472c4" %)**0x06 00 aa bb cc** 1194 1194 ... ... @@ -1359,7 +1359,7 @@ 1359 1359 ))) 1360 1360 1361 1361 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 1362 -|=(% style="width: 155px; background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 112px; background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 24 2px; background-color:#4F81BD;color:white" %)**parameters**1389 +|=(% style="width: 155px; background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 112px; background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 243px; background-color:#4F81BD;color:white" %)**parameters** 1363 1363 |(% colspan="1" rowspan="3" style="width:155px" %)((( 1364 1364 AT+PWMOUT=a,b,c 1365 1365
- image-20250402103902-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.0 KB - Content
- image-20250402104508-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.7 KB - Content