Changes for page SN50v3-LB/LS -- LoRaWAN Sensor Node User Manual
Last modified by Xiaoling on 2025/06/12 15:06
From version 110.1
edited by Xiaoling
on 2025/03/29 08:57
on 2025/03/29 08:57
Change comment:
Uploaded new attachment "image-20250329085729-1.jpeg", version {1}
To version 108.1
edited by Mengting Qiu
on 2025/03/28 17:14
on 2025/03/28 17:14
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.ting - Content
-
... ... @@ -1104,9 +1104,9 @@ 1104 1104 === 3.3.3 Set Interrupt Mode === 1105 1105 1106 1106 1107 -==== 3.3.3.1 Before V1.3. 4firmware ====1107 +==== 3.3.3.1 Before V1.3.3 firmware ==== 1108 1108 1109 -(% style="color:red" %)**Note: Before V1.3. 4firmware, the interrupt function of PA8,PA4,PB15 had only one parameter to set, which was used to set the interrupt trigger mode.**1109 +(% style="color:red" %)**Note: Before V1.3.3 firmware, the interrupt function of PA8,PA4,PB15 had only one parameter to set, which was used to set the interrupt trigger mode.** 1110 1110 1111 1111 Feature, Set Interrupt mode for PA8, PA4, PB15. 1112 1112 ... ... @@ -1147,10 +1147,11 @@ 1147 1147 * Downlink Payload: **06 00 01 02 **~/~/ Equal to AT+INTMOD2=2 1148 1148 * Downlink Payload: **06 00 02 03 **~/~/ Equal to AT+INTMOD3=3 1149 1149 1150 -==== 3.3.3.2 Since V1.3.4 firmware ==== 1151 1151 1152 - (% style="color:red"%)**Note:Since V1.3.4firmware,the Interrupt function has added a new parameter to set the delay time, i.e. the state hold time.**1151 +==== 3.3.3.2 Since V1.3.3 firmware ==== 1153 1153 1153 +(% style="color:red" %)**Note: Since V1.3.3 firmware, the Interrupt function has added a new parameter to set the delay time, i.e. the state hold time.** 1154 + 1154 1154 (% style="color:#037691" %)**AT Command:**(% style="color:blue" %)** **(% style="color:#4472c4" %)**AT+INTMODx=a,b** 1155 1155 1156 1156 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:420px" %) ... ... @@ -1191,6 +1191,7 @@ 1191 1191 * AT+INTMOD2=2,1000 ~/~/Set the interrupt of the PA4 pin to be triggered by the falling edge, however, the interrupt will only be triggered if the low level state remains 1000ms 1192 1192 * AT+INTMOD3=3,2500 ~/~/Set the interrupt of the PB15 pin to be triggered by the rising edge, however, the interrupt will only be triggered if the high level state remains 2500ms 1193 1193 1195 + 1194 1194 (% style="color:#037691" %)**Downlink Command:**(% style="color:blue" %)** **(% style="color:#4472c4" %)**0x06 00 aa bb cc** 1195 1195 1196 1196 Format: Command Code (0x06 00) followed by 4 bytes. ... ... @@ -1203,10 +1203,11 @@ 1203 1203 1204 1204 **Example:** 1205 1205 1206 -* Downlink Payload: **06 00 00 01 00 00 1207 -* Downlink Payload: **06 00 01 02 0B B8 1208 -* Downlink Payload: **06 00 02 03 03 E8 1208 +* Downlink Payload: **06 00 00 01 00 00 **~/~/ Equal to AT+INTMOD1=1,0 1209 +* Downlink Payload: **06 00 01 02 0B B8 **~/~/ Equal to AT+INTMOD2=2,3000 1210 +* Downlink Payload: **06 00 02 03 03 E8 **~/~/ Equal to AT+INTMOD3=3,1000 1209 1209 1212 + 1210 1210 === 3.3.4 Set Power Output Duration === 1211 1211 1212 1212
- image-20250329085729-1.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -363.5 KB - Content