<
From version < 97.1 >
edited by kai
on 2024/04/23 16:29
To version < 101.1 >
edited by Bei Jinggeng
on 2024/07/29 17:48
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.kai
1 +XWiki.Bei
Content
... ... @@ -1050,30 +1050,27 @@
1050 1050  [[image:image-20230627180303-6.png||height="292" width="1171"]]
1051 1051  
1052 1052  
1053 -=== 2.6.7 Example 6 ~-~- Connect to GroPoint_SDI-12 ===
1053 +=== 2.6.7 Example 6 ~-~- Connect to GroPoint Profile-8 (SDI-12 Version) ===
1054 1054  
1055 -==== 2.6.7.1Reference Manual and Command ====
1055 +==== 2.6.7.1  Reference Manual and Command ====
1056 1056  
1057 -
1058 1058  * [[https:~~/~~/static1.squarespace.com/static/5db0b690c4990258f8f6d042/t/64189e1ab3ebc54e6947b0c0/1679334941034/2625-N-T+GroPoint+Profile+User+Manual-V1.1.3.pdf>>https://static1.squarespace.com/static/5db0b690c4990258f8f6d042/t/64189e1ab3ebc54e6947b0c0/1679334941034/2625-N-T+GroPoint+Profile+User+Manual-V1.1.3.pdf]]
1059 1059  
1060 1060  * Commands to be used in PC and output.
1061 1061  
1062 -1.check device address
1061 +1. check device address
1062 +1. change device address
1063 +1. check device ID
1064 +1. start measure
1065 +1. Get Meausre result
1063 1063  
1064 -2.change device address
1065 -
1066 -3.check device ID
1067 -
1068 -4.start measure
1069 -
1070 -5.Get Meausre result
1071 -
1072 1072  [[image:image-20240423143921-1.png]]
1073 1073  
1074 1074  
1075 1075  ==== 2.6.7.2 Hardware Connection to SDI-12-LB/LS ====
1076 1076  
1072 +Note: When the bytes returned by the sensor are not fixed, the full byte interception can be used: AT+ALLDATAMOD=1 (The DATACUTx parameter needs to be cleared when using this directive, or it will not work.)
1073 +
1077 1077  [[image:image-20240423145522-2.png||height="345" width="400"]]
1078 1078  
1079 1079  
... ... @@ -1081,12 +1081,13 @@
1081 1081  
1082 1082  [[image:image-20240423151202-3.png]]
1083 1083  
1084 -==== [[image:image-20240423162851-6.png||height="242" width="903"]] ====
1081 +(% class="wikigeneratedid" id="H" %)
1082 +[[image:image-20240423162851-6.png||height="251" width="935"]]
1085 1085  
1086 1086  
1087 1087  DATA in TTN:
1088 1088  
1089 -[[image:image-20240423162322-4.png||height="220" width="762"]]
1087 +[[image:image-20240423162322-4.png||height="269" width="933"]]
1090 1090  
1091 1091  
1092 1092  == 2.7 Frequency Plans ==
... ... @@ -1384,11 +1384,35 @@
1384 1384  
1385 1385  == 7.3 How to change the LoRa Frequency Bands/Region? ==
1386 1386  
1387 -
1388 1388  You can follow the instructions for [[how to upgrade image>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]].
1389 1389  When downloading the images, choose the required image file for download. ​
1390 1390  
1391 1391  
1389 +== 7.4 Why is the data uploaded to the LoRaWAN platform node empty and fProt~=0? ==
1390 +
1391 +This is due to The length of bytes sent by the node is limited by the lorawan protocol, and the fixed DR needs to be adjusted to improve this problem.
1392 +
1393 +Please refer to the following link for the number of bytes limited by different frequencies and different DRs in the lorawan protocol
1394 +
1395 +[[lora-alliance.org/wp-content/uploads/2021/05/RP002-1.0.3-FINAL-1.pdf>>url:https://lora-alliance.org/wp-content/uploads/2021/05/RP002-1.0.3-FINAL-1.pdf]]
1396 +
1397 +Example:
1398 +
1399 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20240620145456-1.png?rev=1.1||alt="image-20240620145456-1.png"]]
1400 +
1401 +Please refer to the following command to fix DR
1402 +
1403 +AT+ADR=0
1404 +
1405 +AT+DR=3
1406 +
1407 +Downlink command:
1408 +
1409 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.4DataRate>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.4DataRate]]
1410 +
1411 +(% class="wikigeneratedid" %)
1412 += =
1413 +
1392 1392  = 8. ​Order Info =
1393 1393  
1394 1394  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0