<
From version < 95.1 >
edited by kai
on 2024/04/23 16:28
To version < 101.1 >
edited by Bei Jinggeng
on 2024/07/29 17:48
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.kai
1 +XWiki.Bei
Content
... ... @@ -1050,6 +1050,43 @@
1050 1050  [[image:image-20230627180303-6.png||height="292" width="1171"]]
1051 1051  
1052 1052  
1053 +=== 2.6.7 Example 6 ~-~- Connect to GroPoint Profile-8 (SDI-12 Version) ===
1054 +
1055 +==== 2.6.7.1  Reference Manual and Command ====
1056 +
1057 +* [[https:~~/~~/static1.squarespace.com/static/5db0b690c4990258f8f6d042/t/64189e1ab3ebc54e6947b0c0/1679334941034/2625-N-T+GroPoint+Profile+User+Manual-V1.1.3.pdf>>https://static1.squarespace.com/static/5db0b690c4990258f8f6d042/t/64189e1ab3ebc54e6947b0c0/1679334941034/2625-N-T+GroPoint+Profile+User+Manual-V1.1.3.pdf]]
1058 +
1059 +* Commands to be used in PC and output.
1060 +
1061 +1. check device address
1062 +1. change device address
1063 +1. check device ID
1064 +1. start measure
1065 +1. Get Meausre result
1066 +
1067 +[[image:image-20240423143921-1.png]]
1068 +
1069 +
1070 +==== 2.6.7.2 Hardware Connection to SDI-12-LB/LS ====
1071 +
1072 +Note: When the bytes returned by the sensor are not fixed, the full byte interception can be used: AT+ALLDATAMOD=1 (The DATACUTx parameter needs to be cleared when using this directive, or it will not work.)
1073 +
1074 +[[image:image-20240423145522-2.png||height="345" width="400"]]
1075 +
1076 +
1077 +==== 2.6.7.3 Commands set in SDI-12-LB/LS and uplink payload ====
1078 +
1079 +[[image:image-20240423151202-3.png]]
1080 +
1081 +(% class="wikigeneratedid" id="H" %)
1082 +[[image:image-20240423162851-6.png||height="251" width="935"]]
1083 +
1084 +
1085 +DATA in TTN:
1086 +
1087 +[[image:image-20240423162322-4.png||height="269" width="933"]]
1088 +
1089 +
1053 1053  == 2.7 Frequency Plans ==
1054 1054  
1055 1055  
... ... @@ -1345,11 +1345,35 @@
1345 1345  
1346 1346  == 7.3 How to change the LoRa Frequency Bands/Region? ==
1347 1347  
1348 -
1349 1349  You can follow the instructions for [[how to upgrade image>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]].
1350 1350  When downloading the images, choose the required image file for download. ​
1351 1351  
1352 1352  
1389 +== 7.4 Why is the data uploaded to the LoRaWAN platform node empty and fProt~=0? ==
1390 +
1391 +This is due to The length of bytes sent by the node is limited by the lorawan protocol, and the fixed DR needs to be adjusted to improve this problem.
1392 +
1393 +Please refer to the following link for the number of bytes limited by different frequencies and different DRs in the lorawan protocol
1394 +
1395 +[[lora-alliance.org/wp-content/uploads/2021/05/RP002-1.0.3-FINAL-1.pdf>>url:https://lora-alliance.org/wp-content/uploads/2021/05/RP002-1.0.3-FINAL-1.pdf]]
1396 +
1397 +Example:
1398 +
1399 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20240620145456-1.png?rev=1.1||alt="image-20240620145456-1.png"]]
1400 +
1401 +Please refer to the following command to fix DR
1402 +
1403 +AT+ADR=0
1404 +
1405 +AT+DR=3
1406 +
1407 +Downlink command:
1408 +
1409 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.4DataRate>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.4DataRate]]
1410 +
1411 +(% class="wikigeneratedid" %)
1412 += =
1413 +
1353 1353  = 8. ​Order Info =
1354 1354  
1355 1355  
image-20240423162851-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.kai
Size
... ... @@ -1,0 +1,1 @@
1 +45.6 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0