Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Xiaoling on 2025/04/25 08:58
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. kai1 +XWiki.Bei - Content
-
... ... @@ -1050,6 +1050,43 @@ 1050 1050 [[image:image-20230627180303-6.png||height="292" width="1171"]] 1051 1051 1052 1052 1053 +=== 2.6.7 Example 6 ~-~- Connect to GroPoint Profile-8 (SDI-12 Version) === 1054 + 1055 +==== 2.6.7.1 Reference Manual and Command ==== 1056 + 1057 +* [[https:~~/~~/static1.squarespace.com/static/5db0b690c4990258f8f6d042/t/64189e1ab3ebc54e6947b0c0/1679334941034/2625-N-T+GroPoint+Profile+User+Manual-V1.1.3.pdf>>https://static1.squarespace.com/static/5db0b690c4990258f8f6d042/t/64189e1ab3ebc54e6947b0c0/1679334941034/2625-N-T+GroPoint+Profile+User+Manual-V1.1.3.pdf]] 1058 + 1059 +* Commands to be used in PC and output. 1060 + 1061 +1. check device address 1062 +1. change device address 1063 +1. check device ID 1064 +1. start measure 1065 +1. Get Meausre result 1066 + 1067 +[[image:image-20240423143921-1.png]] 1068 + 1069 + 1070 +==== 2.6.7.2 Hardware Connection to SDI-12-LB/LS ==== 1071 + 1072 +Note: When the bytes returned by the sensor are not fixed, the full byte interception can be used: AT+ALLDATAMOD=1 (The DATACUTx parameter needs to be cleared when using this directive, or it will not work.) 1073 + 1074 +[[image:image-20240423145522-2.png||height="345" width="400"]] 1075 + 1076 + 1077 +==== 2.6.7.3 Commands set in SDI-12-LB/LS and uplink payload ==== 1078 + 1079 +[[image:image-20240423151202-3.png]] 1080 + 1081 +(% class="wikigeneratedid" id="H" %) 1082 +[[image:image-20240423162851-6.png||height="251" width="935"]] 1083 + 1084 + 1085 +DATA in TTN: 1086 + 1087 +[[image:image-20240423162322-4.png||height="269" width="933"]] 1088 + 1089 + 1053 1053 == 2.7 Frequency Plans == 1054 1054 1055 1055 ... ... @@ -1345,11 +1345,35 @@ 1345 1345 1346 1346 == 7.3 How to change the LoRa Frequency Bands/Region? == 1347 1347 1348 - 1349 1349 You can follow the instructions for [[how to upgrade image>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]. 1350 1350 When downloading the images, choose the required image file for download. 1351 1351 1352 1352 1389 +== 7.4 Why is the data uploaded to the LoRaWAN platform node empty and fProt~=0? == 1390 + 1391 +This is due to The length of bytes sent by the node is limited by the lorawan protocol, and the fixed DR needs to be adjusted to improve this problem. 1392 + 1393 +Please refer to the following link for the number of bytes limited by different frequencies and different DRs in the lorawan protocol 1394 + 1395 +[[lora-alliance.org/wp-content/uploads/2021/05/RP002-1.0.3-FINAL-1.pdf>>url:https://lora-alliance.org/wp-content/uploads/2021/05/RP002-1.0.3-FINAL-1.pdf]] 1396 + 1397 +Example: 1398 + 1399 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20240620145456-1.png?rev=1.1||alt="image-20240620145456-1.png"]] 1400 + 1401 +Please refer to the following command to fix DR 1402 + 1403 +AT+ADR=0 1404 + 1405 +AT+DR=3 1406 + 1407 +Downlink command: 1408 + 1409 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.4DataRate>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.4DataRate]] 1410 + 1411 +(% class="wikigeneratedid" %) 1412 += = 1413 + 1353 1353 = 8. Order Info = 1354 1354 1355 1355
- image-20240423162851-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.kai - Size
-
... ... @@ -1,0 +1,1 @@ 1 +45.6 KB - Content