Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Xiaoling on 2025/04/25 08:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,14 +3,6 @@ 1 - 2 - 3 3 (% style="text-align:center" %) 4 -[[image:image-202 40103165259-3.png]]2 +[[image:image-20230131183542-1.jpeg||_mstalt="470678" height="694" width="694"]] 5 5 6 - 7 - 8 - 9 - 10 - 11 - 12 12 **Table of Contents:** 13 13 14 14 {{toc/}} ... ... @@ -31,7 +31,7 @@ 31 31 32 32 33 33 ((( 34 -The Dragino (% style="color:blue" %)**SDI-12-LB /LS**(%%) is a (% style="color:blue" %)**SDI-12 to LoRaWAN Converter **(%%)designed for Smart Agriculture solution.26 +The Dragino (% style="color:blue" %)**SDI-12-LB**(%%) is a (% style="color:blue" %)**SDI-12 to LoRaWAN Converter **(%%)designed for Smart Agriculture solution. 35 35 ))) 36 36 37 37 ((( ... ... @@ -39,19 +39,19 @@ 39 39 ))) 40 40 41 41 ((( 42 -SDI-12-LB /LShas SDI-12 interface and support 12v output to power external SDI-12 sensor. It can get the environment data from SDI-12 sensor and sends out the data via LoRaWAN wireless protocol.34 +SDI-12-LB has SDI-12 interface and support 12v output to power external SDI-12 sensor. It can get the environment data from SDI-12 sensor and sends out the data via LoRaWAN wireless protocol. 43 43 ))) 44 44 45 45 ((( 46 -The LoRa wireless technology used in SDI-12-LB /LSallows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.38 +The LoRa wireless technology used in SDI-12-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 47 47 ))) 48 48 49 49 ((( 50 -SDI-12-LB /LSis powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%)or (%style="color:blue" %)**solar powered + li-on battery**(%%)it is designed for long term use up to 5 years.42 +SDI-12-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 51 51 ))) 52 52 53 53 ((( 54 -Each SDI-12-LB /LSis pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.46 +Each SDI-12-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 55 55 ))) 56 56 57 57 ... ... @@ -71,8 +71,7 @@ 71 71 * Support wireless OTA update firmware 72 72 * Uplink on periodically 73 73 * Downlink to change configure 74 -* 8500mAh Li/SOCl2 Battery (SDI-12-LB) 75 -* Solar panel + 3000mAh Li-on battery (SDI-12-LS) 66 +* 8500mAh Battery for long term use 76 76 77 77 == 1.3 Specification == 78 78 ... ... @@ -85,7 +85,7 @@ 85 85 86 86 (% style="color:#037691" %)**Common DC Characteristics:** 87 87 88 -* Supply Voltage: Built-in Battery,2.5v ~~ 3.6v79 +* Supply Voltage: 2.5v ~~ 3.6v 89 89 * Support current: 5V 300mA, 12V 100mA 90 90 * Operating Temperature: -40 ~~ 85°C 91 91 ... ... @@ -163,7 +163,7 @@ 163 163 == 1.8 BLE connection == 164 164 165 165 166 -SDI-12-LB /LSsupport BLE remote configure.157 +SDI-12-LB support BLE remote configure. 167 167 168 168 BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case: 169 169 ... ... @@ -176,7 +176,6 @@ 176 176 177 177 == 1.9 Mechanical == 178 178 179 -=== 1.9.1 for LB version === 180 180 181 181 [[image:image-20230201090139-2.png||_mstalt="428623"]] 182 182 ... ... @@ -185,18 +185,12 @@ 185 185 [[image:image-20230201090139-4.png||_mstalt="429351"]] 186 186 187 187 188 -=== 1.9.2 for LS version === 189 - 190 - 191 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SN50v3-LB/WebHome/image-20231231203439-3.png?width=886&height=385&rev=1.1||alt="image-20231231203439-3.png"]] 192 - 193 - 194 194 = 2. Configure SDI-12 to connect to LoRaWAN network = 195 195 196 196 == 2.1 How it works == 197 197 198 198 199 -The SDI-12-LB /LSis configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and activate the SDI-12-LB/LS. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.183 +The SDI-12-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and activate the SDI-12-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes. 200 200 201 201 202 202 == 2.2 Quick guide to connect to LoRaWAN server (OTAA) == ... ... @@ -211,9 +211,9 @@ 211 211 The LPS8V2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server. 212 212 213 213 214 -(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from SDI-12-LB /LS.198 +(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from SDI-12-LB. 215 215 216 -Each SDI-12-LB /LSis shipped with a sticker with the default device EUI as below:200 +Each SDI-12-LB is shipped with a sticker with the default device EUI as below: 217 217 218 218 [[image:image-20230426084456-1.png||height="241" width="519"]] 219 219 ... ... @@ -243,10 +243,10 @@ 243 243 [[image:1675213686734-883.png||_mstalt="298064"]] 244 244 245 245 246 -(% style="color:blue" %)**Step 2**(%%): Activate on SDI-12-LB /LS230 +(% style="color:blue" %)**Step 2**(%%): Activate on SDI-12-LB 247 247 248 248 249 -Press the button for 5 seconds to activate the SDI-12-LB /LS.233 +Press the button for 5 seconds to activate the SDI-12-LB. 250 250 251 251 (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode** (%%)for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 252 252 ... ... @@ -257,7 +257,7 @@ 257 257 == 2.3 SDI-12 Related Commands == 258 258 259 259 260 -User need to configure SDI-12-LB /LSto communicate with SDI-12 sensors otherwise the uplink payload will only include a few bytes.244 +User need to configure SDI-12-LB to communicate with SDI-12 sensors otherwise the uplink payload will only include a few bytes. 261 261 262 262 263 263 === 2.3.1 Basic SDI-12 debug command === ... ... @@ -265,7 +265,7 @@ 265 265 266 266 User can run some basic SDI-12 command to debug the connection to the SDI-12 sensor. These commands can be sent via AT Command or LoRaWAN downlink command. 267 267 268 -If SDI-12 sensor return value after get these commands, //SDI-12-LB/ LS//will uplink the return on FPORT=100, otherwise, if there is no response from SDI-12 sensor. //SDI-12-LB/LS//will uplink NULL (0x 4E 55 4C 4C) to server.252 +If SDI-12 sensor return value after get these commands, //SDI-12-LB// will uplink the return on FPORT=100, otherwise, if there is no response from SDI-12 sensor. //SDI-12-LB// will uplink NULL (0x 4E 55 4C 4C) to server. 269 269 270 270 The following is the display information on the serial port and the server. 271 271 ... ... @@ -483,7 +483,7 @@ 483 483 484 484 AT+COMMANDx & AT+DATACUTx 485 485 486 -User can define max 15 SDI-12 Commands (AT+COMMAND1 ~~ AT+COMMANDF). On each uplink period (TDC time, default 20 minutes), SDI-12-LB /LSwill send these SDI-12 commands and wait for return from SDI-12 sensors. SDI-12-LB/LSwill then combine these returns and uplink via LoRaWAN.470 +User can define max 15 SDI-12 Commands (AT+COMMAND1 ~~ AT+COMMANDF). On each uplink period (TDC time, default 20 minutes), SDI-12-LB will send these SDI-12 commands and wait for return from SDI-12 sensors. SDI-12-LB will then combine these returns and uplink via LoRaWAN. 487 487 488 488 489 489 * (% style="color:blue" %)**AT Command:** ... ... @@ -496,7 +496,7 @@ 496 496 497 497 (% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. 498 498 499 -(% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB /LSwill resend this command. Max 3 retries.483 +(% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB will resend this command. Max 3 retries. 500 500 501 501 (% style="color:red" %)**0 **(%%) No validation check; 502 502 ... ... @@ -548,7 +548,7 @@ 548 548 * (% style="color:#037691" %)**NN **(%%): 1: set the AT+COMMAND value ; 2: set the AT+DATACUT value. 549 549 * (% style="color:#037691" %)**LL **(%%): The length of AT+COMMAND or AT+DATACUT command 550 550 * (% style="color:#037691" %)**XX XX XX XX **(%%): AT+COMMAND or AT+DATACUT command 551 -* (% style="color:#037691" %)**YY **(%%): If YY=0, SDI-12-LB /LSwill execute the downlink command without uplink; if YY=1, SDI-12-LB/LSwill execute an uplink after got this command.535 +* (% style="color:#037691" %)**YY **(%%): If YY=0, SDI-12-LB will execute the downlink command without uplink; if YY=1, SDI-12-LB will execute an uplink after got this command. 552 552 553 553 (% style="color:blue" %)**Example:** 554 554 ... ... @@ -643,9 +643,9 @@ 643 643 === 2.4.1 Device Payload, FPORT~=5 === 644 644 645 645 646 -Include device configure status. Once SDI-12-LB /LSJoined the network, it will uplink this message to the server.630 +Include device configure status. Once SDI-12-LB Joined the network, it will uplink this message to the server. 647 647 648 -Users can also use the downlink command(0x26 01) to ask SDI-12-LB /LSto resend this uplink.632 +Users can also use the downlink command(0x26 01) to ask SDI-12-LB to resend this uplink. 649 649 650 650 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 651 651 |(% colspan="6" style="background-color:#d9e2f3; color:#0070c0" %)**Device Status (FPORT=5)** ... ... @@ -657,7 +657,7 @@ 657 657 [[image:1675215946738-635.png||_mstalt="297778"]] 658 658 659 659 660 -(% style="color:#037691" %)**Sensor Model**(%%): For SDI-12-LB /LS, this value is 0x17644 +(% style="color:#037691" %)**Sensor Model**(%%): For SDI-12-LB, this value is 0x17 661 661 662 662 (% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version 663 663 ... ... @@ -738,7 +738,7 @@ 738 738 === 2.4.3 Battery Info === 739 739 740 740 741 -Check the battery voltage for SDI-12-LB /LS.725 +Check the battery voltage for SDI-12-LB. 742 742 743 743 Ex1: 0x0B45 = 2885mV 744 744 ... ... @@ -773,13 +773,13 @@ 773 773 774 774 There is no fix payload decoder in LoRaWAN server because the SDI-12 sensors returns are different. User need to write the decoder themselves for their case. 775 775 776 -SDI-12-LB /LSTTN Payload Decoder: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>url:https://github.com/dragino/dragino-end-node-decoder]]760 +SDI-12-LB TTN Payload Decoder: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>url:https://github.com/dragino/dragino-end-node-decoder]] 777 777 778 778 779 779 == 2.5 Uplink Interval == 780 780 781 781 782 -The SDI-12-LB /LSby default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link:766 +The SDI-12-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: 783 783 784 784 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]] 785 785 ... ... @@ -789,7 +789,7 @@ 789 789 === 2.6.1 Examples 1 ~-~- General Example === 790 790 791 791 792 -COM port and SDI-12 sensor communication converted to SDI-12-LB /LSand SDI-12 sensor communication.776 +COM port and SDI-12 sensor communication converted to SDI-12-LB and SDI-12 sensor communication. 793 793 794 794 [[image:image-20230222143809-1.png||_mstalt="429962" height="564" width="729"]] 795 795 ... ... @@ -874,13 +874,13 @@ 874 874 [[image:image-20230603120209-2.png||height="281" width="267"]] 875 875 876 876 877 -==== 2.6.2.2 Hardware Connection to SDI-12-LB /LS====861 +==== 2.6.2.2 Hardware Connection to SDI-12-LB ==== 878 878 879 879 880 880 [[image:image-20230603120515-3.png]] 881 881 882 882 883 -==== 2.6.2.3 Commands set in SDI-12-LB /LSand uplink payload ====867 +==== 2.6.2.3 Commands set in SDI-12-LB and uplink payload ==== 884 884 885 885 886 886 [[image:image-20230603120648-4.png]] ... ... @@ -915,13 +915,13 @@ 915 915 [[image:image-20230603121606-7.png||height="242" width="307"]] 916 916 917 917 918 -==== 2.6.3.2 Hardware Connection to SDI-12-LB /LS====902 +==== 2.6.3.2 Hardware Connection to SDI-12-LB ==== 919 919 920 920 921 921 [[image:image-20230603121643-8.png||height="442" width="656"]] 922 922 923 923 924 -==== 2.6.3.3 Commands set in SDI-12-LB /LSand uplink payload ====908 +==== 2.6.3.3 Commands set in SDI-12-LB and uplink payload ==== 925 925 926 926 927 927 [[image:image-20230603121721-9.png]] ... ... @@ -956,13 +956,13 @@ 956 956 [[image:image-20230603122248-16.png||height="196" width="198"]] 957 957 958 958 959 -==== 2.6.4.2 Hardware Connection to SDI-12-LB /LS====943 +==== 2.6.4.2 Hardware Connection to SDI-12-LB ==== 960 960 961 961 962 962 [[image:image-20230603122212-15.png||height="502" width="667"]] 963 963 964 964 965 -==== 2.6.4.3 Commands set in SDI-12-LB /LSand uplink payload ====949 +==== 2.6.4.3 Commands set in SDI-12-LB and uplink payload ==== 966 966 967 967 968 968 [[image:image-20230603122040-12.png]] ... ... @@ -986,15 +986,15 @@ 986 986 987 987 * The sensor needs to be powered to a steady statue. So the 12VT time need to be set to the maximum stable time for the sensors. in this example, it is 13 seconds. 988 988 989 -* If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB /LS.973 +* If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB. 990 990 991 -==== 2.6.5.2 Hardware Connection to SDI-12-LB /LS====975 +==== 2.6.5.2 Hardware Connection to SDI-12-LB ==== 992 992 993 993 994 994 [[image:image-20230603122508-17.png||height="526" width="742"]] 995 995 996 996 997 -==== 2.6.5.3 Commands set in SDI-12-LB /LSand uplink payload ====981 +==== 2.6.5.3 Commands set in SDI-12-LB and uplink payload ==== 998 998 999 999 1000 1000 [[image:image-20230603122549-18.png]] ... ... @@ -1030,7 +1030,7 @@ 1030 1030 [[image:image-20230627174559-3.png]] 1031 1031 1032 1032 1033 -==== 2.6.6.2 Hardware Connection to SDI-12-LB /LS====1017 +==== 2.6.6.2 Hardware Connection to SDI-12-LB ==== 1034 1034 1035 1035 1036 1036 [[image:image-20230627174446-2.png]] ... ... @@ -1037,7 +1037,7 @@ 1037 1037 1038 1038 1039 1039 1040 -==== 2.6.6.3 Commands set in SDI-12-LB /LSand uplink payload ====1024 +==== 2.6.6.3 Commands set in SDI-12-LB and uplink payload ==== 1041 1041 1042 1042 1043 1043 [[image:image-20230627175513-4.png||height="596" width="576"]] ... ... @@ -1053,7 +1053,7 @@ 1053 1053 == 2.7 Frequency Plans == 1054 1054 1055 1055 1056 -The SDI-12-LB /LSuses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.1040 +The SDI-12-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 1057 1057 1058 1058 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 1059 1059 ... ... @@ -1066,15 +1066,15 @@ 1066 1066 [[https:~~/~~/www.dropbox.com/sh/qrbgbikb109lkiv/AACBR-v_ZhZAMengcY7Nsa1ja?dl=0>>https://www.dropbox.com/sh/qrbgbikb109lkiv/AACBR-v_ZhZAMengcY7Nsa1ja?dl=0]] 1067 1067 1068 1068 1069 -= 3. Configure SDI-12-LB /LSvia AT Command or LoRaWAN Downlink =1053 += 3. Configure SDI-12-LB via AT Command or LoRaWAN Downlink = 1070 1070 1071 1071 1072 -Use can configure SDI-12-LB /LSvia AT Command or LoRaWAN Downlink.1056 +Use can configure SDI-12-LB via AT Command or LoRaWAN Downlink. 1073 1073 1074 1074 * AT Command Connection: See [[FAQ>>||anchor="H7.FAQ"]]. 1075 1075 * LoRaWAN Downlink instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 1076 1076 1077 -There are two kinds of commands to configure SDI-12-LB /LS, they are:1061 +There are two kinds of commands to configure SDI-12-LB, they are: 1078 1078 1079 1079 * (% style="color:blue" %)**General Commands**. 1080 1080 ... ... @@ -1088,9 +1088,9 @@ 1088 1088 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 1089 1089 1090 1090 1091 -* (% style="color:blue" %)**Commands special design for SDI-12-LB /LS**1075 +* (% style="color:blue" %)**Commands special design for SDI-12-LB** 1092 1092 1093 -These commands only valid for SDI-12-LB /LS, as below:1077 +These commands only valid for SDI-12-LB, as below: 1094 1094 1095 1095 1096 1096 == 3.1 Set Transmit Interval Time == ... ... @@ -1304,7 +1304,7 @@ 1304 1304 = 4. Battery & Power Consumption = 1305 1305 1306 1306 1307 -SDI-12-LB use ER26500 + SPC1520 battery pack and SDI-12-LS use 3000mAh Recharable Battery with Solar Panel. See below link for detail information about the battery info and how to replace.1291 +SDI-12-LB uses ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 1308 1308 1309 1309 [[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 1310 1310 ... ... @@ -1354,7 +1354,7 @@ 1354 1354 1355 1355 1356 1356 ((( 1357 -(% style="color:blue" %)**Part Number: SDI-12-LB-XX-YY or SDI-12-LS-XX-YY**1341 +(% style="color:blue" %)**Part Number: SDI-12-LB-XX-YY** 1358 1358 ))) 1359 1359 1360 1360 ((( ... ... @@ -1382,7 +1382,7 @@ 1382 1382 1383 1383 (% style="color:#037691" %)**Package Includes**: 1384 1384 1385 -* SDI-12-LB orSDI-12-LSSDI-12to LoRaWAN Converter x 11369 +* SDI-12-LB SDI-12 to LoRaWAN Converter x 1 1386 1386 1387 1387 (% style="color:#037691" %)**Dimension and weight**: 1388 1388
- image-20240103165115-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -220.0 KB - Content
- image-20240103165259-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -235.3 KB - Content