Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Xiaoling on 2025/04/25 08:58
Change comment:
Uploaded new attachment "image-20230627180303-6.png", version {1}
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -66,6 +66,7 @@ 66 66 * 8500mAh Battery for long term use 67 67 68 68 69 + 69 69 == 1.3 Specification == 70 70 71 71 ... ... @@ -78,7 +78,8 @@ 78 78 (% style="color:#037691" %)**Common DC Characteristics:** 79 79 80 80 * Supply Voltage: 2.5v ~~ 3.6v 81 -* Support current: 5V 300mA, 12V 100mA 82 +* Support current: 5V 300mA 83 + 12V 100mA 82 82 * Operating Temperature: -40 ~~ 85°C 83 83 84 84 (% style="color:#037691" %)**LoRa Spec:** ... ... @@ -114,6 +114,7 @@ 114 114 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 115 115 116 116 119 + 117 117 == 1.4 Connect to SDI-12 Sensor == 118 118 119 119 ... ... @@ -148,6 +148,7 @@ 148 148 |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode. 149 149 150 150 154 + 151 151 == 1.7 Pin Mapping == 152 152 153 153 ... ... @@ -358,6 +358,7 @@ 358 358 359 359 360 360 365 + 361 361 ==== (% style="color:blue" %)**aR0!- aR9!, aRC0!- aRC9!**(%%) ==== 362 362 363 363 ... ... @@ -426,25 +426,17 @@ 426 426 [[image:image-20230201092355-17.png||_mstalt="454337" height="426" width="1135"]] 427 427 428 428 429 -(% style="color:blue" %)**Example2: **(%%) AT+CFGDEV =0M!,1,1 434 +(% style="color:blue" %)**Example2: **(%%) AT+CFGDEV =0M!,1,1 or AT+CFGDEV =0C!,1,1 430 430 431 431 (% style="color:#037691" %)**0M! **(%%): SDI-12 Command, 432 432 433 433 (% style="color:#037691" %)**1 **(%%): Delay 1 second. ( 0: 810 mini-second) 434 434 435 -(% style="color:#037691" %)**1 **(%%): 440 +(% style="color:#037691" %)**1 **(%%):Use aD0! command access. 436 436 437 437 Equal Downlink: 0xA8 03 30 4D 21 01 01 01 438 438 439 439 440 -The following is the display information on the serial port and the server. 441 - 442 - 443 -[[image:image-20230628091055-1.png||height="368" width="462"]] 444 - 445 -[[image:image-20230628091130-2.png||height="258" width="879"]] 446 - 447 - 448 448 === 2.3.3 Convert ASCII to String === 449 449 450 450 ... ... @@ -913,7 +913,7 @@ 913 913 914 914 [[image:image-20230603121721-9.png]] 915 915 916 -[[image:image-202306 28090323-1.png||height="414" width="694"]]913 +[[image:image-20230603121752-10.png]] 917 917 918 918 Data in TTN: 919 919 ... ... @@ -921,7 +921,7 @@ 921 921 922 922 923 923 924 -=== 2.6.4 Example 4 ~-~- Connect to TEROS-12 === 921 +=== (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.4 Example 4 ~-~- Connect to TEROS-12 === 925 925 926 926 ==== 2.6.4.1 Reference Manual and Command ==== 927 927 ... ... @@ -962,7 +962,7 @@ 962 962 [[image:image-20230603122139-14.png||height="148" width="1128"]] 963 963 964 964 965 -=== 2.6.5 Example 5 ~-~- Connect to SIL-400/TEROS-12 & Hygrovue10 === 962 +=== (% id="cke_bm_1489640S" style="display:none" %) (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.5 Example 5 ~-~- Connect to SIL-400/TEROS-12 & Hygrovue10 === 966 966 967 967 ==== 2.6.5.1 Important Notice! ==== 968 968 ... ... @@ -976,6 +976,7 @@ 976 976 * If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB. 977 977 978 978 976 + 979 979 ==== 2.6.5.2 Hardware Connection to SDI-12-LB ==== 980 980 981 981 ... ... @@ -995,49 +995,6 @@ 995 995 [[image:image-20230603122719-20.png||height="151" width="1179"]] 996 996 997 997 998 -=== 2.6.6 Example 6 ~-~- Connect to ENTELECHY-EP_SDI-12 === 999 - 1000 -==== 2.6.6.1 Reference Manual and Command ==== 1001 - 1002 - 1003 -* [[https:~~/~~/enviroprosoilprobes.com/wp-content/uploads/2019/11/ENTELECHY-EP_SDI-12-Commands.pdf>>url:https://enviroprosoilprobes.com/wp-content/uploads/2019/11/ENTELECHY-EP_SDI-12-Commands.pdf]] 1004 - 1005 -* Commands to be used in PC and output. 1006 - 1007 -1.check device address 1008 - 1009 -2.change device address 1010 - 1011 -3.check device ID 1012 - 1013 -4.start measure 1014 - 1015 -5.Get Meausre result 1016 - 1017 - 1018 -[[image:image-20230627174559-3.png]] 1019 - 1020 - 1021 -==== 2.6.6.2 Hardware Connection to SDI-12-LB ==== 1022 - 1023 - 1024 -[[image:image-20230627174446-2.png]] 1025 - 1026 - 1027 - 1028 -==== 2.6.6.3 Commands set in SDI-12-LB and uplink payload ==== 1029 - 1030 - 1031 -[[image:image-20230627175513-4.png||height="596" width="576"]] 1032 - 1033 -[[image:image-20230627175736-5.png||height="429" width="693"]] 1034 - 1035 - 1036 -**Data in TTN:** 1037 - 1038 -[[image:image-20230627180303-6.png||height="292" width="1171"]] 1039 - 1040 - 1041 1041 == 2.7 Frequency Plans == 1042 1042 1043 1043 ... ... @@ -1102,6 +1102,7 @@ 1102 1102 1103 1103 (% style="color:blue" %)**Downlink Command: 0x01** 1104 1104 1060 + 1105 1105 Format: Command Code (0x01) followed by 3 bytes time value. 1106 1106 1107 1107 If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01. ... ... @@ -1110,6 +1110,7 @@ 1110 1110 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1111 1111 1112 1112 1069 + 1113 1113 == 3.2 Set Interrupt Mode == 1114 1114 1115 1115 ... ... @@ -1142,6 +1142,7 @@ 1142 1142 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1143 1143 1144 1144 1102 + 1145 1145 == 3.3 Set the output time == 1146 1146 1147 1147 ... ... @@ -1214,6 +1214,7 @@ 1214 1214 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 1215 1215 1216 1216 1175 + 1217 1217 == 3.4 Set the all data mode == 1218 1218 1219 1219 ... ... @@ -1237,6 +1237,7 @@ 1237 1237 * Example 2: Downlink Payload: AB 01 ~/~/ AT+ALLDATAMOD=1 1238 1238 1239 1239 1199 + 1240 1240 == 3.5 Set the splicing payload for uplink == 1241 1241 1242 1242 ... ... @@ -1294,6 +1294,7 @@ 1294 1294 * Example 2: Downlink Payload: AE 05 ~/~/ AT+PAYVER=5 1295 1295 1296 1296 1257 + 1297 1297 = 4. Battery & Power Consumption = 1298 1298 1299 1299 ... ... @@ -1381,6 +1381,7 @@ 1381 1381 * Weight / pcs : g 1382 1382 1383 1383 1345 + 1384 1384 = 10. Support = 1385 1385 1386 1386
- image-20230628090323-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Saxer - Size
-
... ... @@ -1,1 +1,0 @@ 1 -137.2 KB - Content
- image-20230628091055-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Saxer - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.9 KB - Content
- image-20230628091130-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Saxer - Size
-
... ... @@ -1,1 +1,0 @@ 1 -84.0 KB - Content