Last modified by Mengting Qiu on 2025/07/03 15:42

From version 87.4
edited by Xiaoling
on 2023/10/23 11:02
Change comment: There is no comment for this version
To version 67.1
edited by Edwin Chen
on 2023/06/03 12:28
Change comment: Uploaded new attachment "image-20230603122508-17.png", version {1}

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Edwin
Content
... ... @@ -78,7 +78,8 @@
78 78  (% style="color:#037691" %)**Common DC Characteristics:**
79 79  
80 80  * Supply Voltage: 2.5v ~~ 3.6v
81 -* Support current: 5V 300mA, 12V 100mA
81 +* Support current: 5V 300mA
82 + 12V 100mA
82 82  * Operating Temperature: -40 ~~ 85°C
83 83  
84 84  (% style="color:#037691" %)**LoRa Spec:**
... ... @@ -117,6 +117,7 @@
117 117  == 1.4 Connect to SDI-12 Sensor ==
118 118  
119 119  
121 +
120 120  [[image:1675212538524-889.png||_mstalt="298272"]]
121 121  
122 122  
... ... @@ -202,6 +202,7 @@
202 202  
203 203  Each SDI-12-LB is shipped with a sticker with the default device EUI as below:
204 204  
207 +
205 205  [[image:image-20230426084456-1.png||height="241" width="519"]]
206 206  
207 207  
... ... @@ -358,6 +358,7 @@
358 358  
359 359  
360 360  
364 +
361 361  ==== (% style="color:blue" %)**aR0!- aR9!,  aRC0!- aRC9!**(%%) ====
362 362  
363 363  
... ... @@ -395,7 +395,7 @@
395 395  This command can be used to debug all SDI-12 command.
396 396  
397 397  
398 -LoRaWAN Downlink: A8 aa xx xx xx xx bb cc dd
402 +LoRaWAN Downlink: A8 aa xx xx xx xx bb cc
399 399  
400 400  (% style="color:#037691" %)**aa **(%%): total SDI-12 command length
401 401  
... ... @@ -405,11 +405,9 @@
405 405  
406 406  (% style="color:#037691" %)**cc **(%%): 0: don't uplink return to LoRaWAN, 1: Uplink return to LoRaWAN on FPORT=100
407 407  
408 -(% style="color:#037691" %)**dd: **(%%) 0: Do not use aD0! command access, 1: use aD0! command access.
409 409  
413 +(% style="color:blue" %)**Example: **(%%) AT+CFGDEV =0RC0!,1
410 410  
411 -(% style="color:blue" %)**Example1: **(%%) AT+CFGDEV =0RC0!,1
412 -
413 413  (% style="color:#037691" %)**0RC0! **(%%): SDI-12 Command,
414 414  
415 415  (% style="color:#037691" %)**1 **(%%): Delay 1 second.  ( 0: 810 mini-second)
... ... @@ -426,25 +426,6 @@
426 426  [[image:image-20230201092355-17.png||_mstalt="454337" height="426" width="1135"]]
427 427  
428 428  
429 -(% style="color:blue" %)**Example2: **(%%) AT+CFGDEV =0M!,1,1
430 -
431 -(% style="color:#037691" %)**0M! **(%%): SDI-12 Command,
432 -
433 -(% style="color:#037691" %)**1 **(%%): Delay 1 second.  ( 0: 810 mini-second)
434 -
435 -(% style="color:#037691" %)**1 **(%%): Use aD0! command access.
436 -
437 -Equal Downlink: 0xA8 03 30  4D 21 01 01 01
438 -
439 -
440 -The following is the display information on the serial port and the server.
441 -
442 -
443 -[[image:image-20230628091055-1.png||height="368" width="462"]]
444 -
445 -[[image:image-20230628091130-2.png||height="258" width="879"]]
446 -
447 -
448 448  === 2.3.3 Convert ASCII to String ===
449 449  
450 450  
... ... @@ -650,33 +650,33 @@
650 650  
651 651  (% style="color:#037691" %)**Frequency Band**:
652 652  
653 -0x01: EU868
636 +*0x01: EU868
654 654  
655 -0x02: US915
638 +*0x02: US915
656 656  
657 -0x03: IN865
640 +*0x03: IN865
658 658  
659 -0x04: AU915
642 +*0x04: AU915
660 660  
661 -0x05: KZ865
644 +*0x05: KZ865
662 662  
663 -0x06: RU864
646 +*0x06: RU864
664 664  
665 -0x07: AS923
648 +*0x07: AS923
666 666  
667 -0x08: AS923-1
650 +*0x08: AS923-1
668 668  
669 -0x09: AS923-2
652 +*0x09: AS923-2
670 670  
671 -0x0a: AS923-3
654 +*0x0a: AS923-3
672 672  
673 -0x0b: CN470
656 +*0x0b: CN470
674 674  
675 -0x0c: EU433
658 +*0x0c: EU433
676 676  
677 -0x0d: KR920
660 +*0x0d: KR920
678 678  
679 -0x0e: MA869
662 +*0x0e: MA869
680 680  
681 681  
682 682  (% style="color:#037691" %)**Sub-Band**:
... ... @@ -707,9 +707,9 @@
707 707  * Periodically Uplink: FPORT=2
708 708  
709 709  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %)
710 -|=(% style="width: 90px;background-color:#D9E2F3;color:#0070C0" %)(((
693 +|=(% style="width: 90px;background-color:#D9E2F3" %)(((
711 711  **Size(bytes)**
712 -)))|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 90px;background-color:#D9E2F3;color:#0070C0" %)**1**|=(% style="width: 240px;background-color:#D9E2F3;color:#0070C0" %)**Length depends on the return from the commands**
695 +)))|=(% style="width: 80px;background-color:#D9E2F3" %)**2**|=(% style="width: 90px;background-color:#D9E2F3" %)**1**|=(% style="width: 240px;background-color:#D9E2F3" %)**Length depends on the return from the commands**
713 713  |(% style="width:93px" %)**Value**|(% style="width:83px" %)(((
714 714  Battery(mV)
715 715  &
... ... @@ -839,24 +839,22 @@
839 839  Partial cut, the cut sensor address and the first two parameters:(% style="color:#037691" %)**AT+DATACUTx=25,2,1~~12, cut out the character field ” 4+30.8+22.84”**.
840 840  
841 841  
842 -=== 2.6.2 Example 2 ~-~- Connect to Hygrovue10 ===
825 +=== 2.6.2 Example ~-~- Connect to Hygrovue10 ===
843 843  
844 844  ==== 2.6.2.1 Reference Manual and Command ====
845 845  
846 -
847 847  * [[Hygrovue10 Product Page>>https://www.campbellsci.com/hygrovue10]]
848 -
849 849  * Commands to be used in PC and output.
850 850  
851 -~1. check device address
832 +1.check device address
852 852  
853 -2. change device address
834 +2.change device address
854 854  
855 -3. check device ID
836 +3.check device ID
856 856  
857 -4. start measure
838 +4.start measure
858 858  
859 -5. Get Meausre result
840 +5.Get Meausre result
860 860  
861 861  [[image:image-20230603120209-2.png||height="281" width="267"]]
862 862  
... ... @@ -863,181 +863,22 @@
863 863  
864 864  ==== 2.6.2.2 Hardware Connection to SDI-12-LB ====
865 865  
866 -
867 867  [[image:image-20230603120515-3.png]]
868 868  
869 869  
870 870  ==== 2.6.2.3 Commands set in SDI-12-LB and uplink payload ====
871 871  
872 -
873 873  [[image:image-20230603120648-4.png]]
874 874  
875 875  [[image:image-20230603120726-5.png]]
876 876  
856 +Data in TTN:
877 877  
878 -**Data in TTN:**
879 -
880 880  [[image:image-20230603120859-6.png||height="118" width="1285"]]
881 881  
882 882  
883 -=== (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.3 Example 3 ~-~- Connect to SIL-400 ===
884 884  
885 -==== 2.6.3.1 Reference Manual and Command ====
886 886  
887 -
888 -* [[SIL-400 Product Page>>https://www.apogeeinstruments.com/sil-411-commercial-grade-sdi-12-digital-output-standard-field-of-view-infrared-radiometer-sensor/]]
889 -
890 -* Commands to be used in PC and output.
891 -
892 -~1. check device address
893 -
894 -2. change device address
895 -
896 -3. check device ID
897 -
898 -4. start measure
899 -
900 -5. Get Meausre result
901 -
902 -[[image:image-20230603121606-7.png||height="242" width="307"]]
903 -
904 -
905 -==== 2.6.3.2 Hardware Connection to SDI-12-LB ====
906 -
907 -
908 -[[image:image-20230603121643-8.png||height="442" width="656"]]
909 -
910 -
911 -==== 2.6.3.3 Commands set in SDI-12-LB and uplink payload ====
912 -
913 -
914 -[[image:image-20230603121721-9.png]]
915 -
916 -[[image:image-20230628090323-1.png||height="414" width="694"]]
917 -
918 -Data in TTN:
919 -
920 -[[image:image-20230603121826-11.png||height="155" width="1104"]]
921 -
922 -
923 -
924 -=== 2.6.4 Example 4 ~-~- Connect to TEROS-12 ===
925 -
926 -==== 2.6.4.1 Reference Manual and Command ====
927 -
928 -
929 -* [[TEROS-12 Product Page>>https://www.metergroup.com/en/meter-environment/products/teros-12-soil-moisture-sensor]]
930 -
931 -* Commands to be used in PC and output.
932 -
933 -1.check device address
934 -
935 -2.change device address
936 -
937 -3.check device ID
938 -
939 -4.start measure
940 -
941 -5.Get Meausre result
942 -
943 -[[image:image-20230603122248-16.png||height="196" width="198"]]
944 -
945 -
946 -==== 2.6.4.2 Hardware Connection to SDI-12-LB ====
947 -
948 -
949 -[[image:image-20230603122212-15.png||height="502" width="667"]]
950 -
951 -
952 -==== 2.6.4.3 Commands set in SDI-12-LB and uplink payload ====
953 -
954 -
955 -[[image:image-20230603122040-12.png]]
956 -
957 -[[image:image-20230603122109-13.png||height="469" width="762"]]
958 -
959 -
960 -**Data in TTN:**
961 -
962 -[[image:image-20230603122139-14.png||height="148" width="1128"]]
963 -
964 -
965 -=== 2.6.5 Example 5 ~-~- Connect to SIL-400/TEROS-12 & Hygrovue10 ===
966 -
967 -==== 2.6.5.1 Important Notice! ====
968 -
969 -
970 -* The product page and reference command see above example 2,3,4
971 -
972 -* All of these SDI-12 sensors use the same address (address 0) by default. So we need to change their address to different address, by using **aAb!** command. See above example.
973 -
974 -* The sensor needs to be powered to a steady statue. So the 12VT time need to be set to the maximum stable time for the sensors. in this example, it is 13 seconds.
975 -
976 -* If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB.
977 -
978 -
979 -==== 2.6.5.2 Hardware Connection to SDI-12-LB ====
980 -
981 -
982 -[[image:image-20230603122508-17.png||height="526" width="742"]]
983 -
984 -
985 -==== 2.6.5.3 Commands set in SDI-12-LB and uplink payload ====
986 -
987 -
988 -[[image:image-20230603122549-18.png]]
989 -
990 -[[image:image-20230603122623-19.png||height="483" width="1121"]]
991 -
992 -
993 -**Data in TTN:**
994 -
995 -[[image:image-20230603122719-20.png||height="151" width="1179"]]
996 -
997 -
998 -=== 2.6.6 Example 6 ~-~- Connect to ENTELECHY-EP_SDI-12 ===
999 -
1000 -==== 2.6.6.1 Reference Manual and Command ====
1001 -
1002 -
1003 -* [[https:~~/~~/enviroprosoilprobes.com/wp-content/uploads/2019/11/ENTELECHY-EP_SDI-12-Commands.pdf>>url:https://enviroprosoilprobes.com/wp-content/uploads/2019/11/ENTELECHY-EP_SDI-12-Commands.pdf]]
1004 -
1005 -* Commands to be used in PC and output.
1006 -
1007 -1.check device address
1008 -
1009 -2.change device address
1010 -
1011 -3.check device ID
1012 -
1013 -4.start measure
1014 -
1015 -5.Get Meausre result
1016 -
1017 -
1018 -[[image:image-20230627174559-3.png]]
1019 -
1020 -
1021 -==== 2.6.6.2 Hardware Connection to SDI-12-LB ====
1022 -
1023 -
1024 -[[image:image-20230627174446-2.png]]
1025 -
1026 -
1027 -
1028 -==== 2.6.6.3 Commands set in SDI-12-LB and uplink payload ====
1029 -
1030 -
1031 -[[image:image-20230627175513-4.png||height="596" width="576"]]
1032 -
1033 -[[image:image-20230627175736-5.png||height="429" width="693"]]
1034 -
1035 -
1036 -**Data in TTN:**
1037 -
1038 -[[image:image-20230627180303-6.png||height="292" width="1171"]]
1039 -
1040 -
1041 1041  == 2.7 Frequency Plans ==
1042 1042  
1043 1043  
... ... @@ -1102,6 +1102,7 @@
1102 1102  
1103 1103  (% style="color:blue" %)**Downlink Command: 0x01**
1104 1104  
927 +
1105 1105  Format: Command Code (0x01) followed by 3 bytes time value.
1106 1106  
1107 1107  If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01.
... ... @@ -1185,10 +1185,8 @@
1185 1185  OK
1186 1186  )))
1187 1187  
1188 -(% style="color:blue" %)**AT Command: AT+12VT **
1011 +(% style="color:blue" %)**AT Command: AT+12VT**
1189 1189  
1190 -(% style="color:blue" %)**(The v1.2 version is enabled for 1 second by default, and the version below v1.2 is disabled by default)**
1191 -
1192 1192  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:443px" %)
1193 1193  |=(% style="width: 156px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 199px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 83px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1194 1194  |(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=?|(% style="background-color:#f2f2f2; width:199px" %)Show 12V open time.|(% style="background-color:#f2f2f2; width:83px" %)(((
... ... @@ -1351,7 +1351,7 @@
1351 1351  )))
1352 1352  
1353 1353  (((
1354 -(% style="color:blue" %)**XXX**(%%): The default frequency band
1175 +XXX: The default frequency band
1355 1355  )))
1356 1356  
1357 1357  (((
image-20230603122549-18.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -90.9 KB
Content
image-20230603122623-19.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -139.5 KB
Content
image-20230603122719-20.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -83.8 KB
Content
image-20230627164957-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bei
Size
... ... @@ -1,1 +1,0 @@
1 -835.0 KB
Content
image-20230627165744-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bei
Size
... ... @@ -1,1 +1,0 @@
1 -4.6 KB
Content
image-20230627174446-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bei
Size
... ... @@ -1,1 +1,0 @@
1 -835.0 KB
Content
image-20230627174559-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bei
Size
... ... @@ -1,1 +1,0 @@
1 -4.6 KB
Content
image-20230627175513-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bei
Size
... ... @@ -1,1 +1,0 @@
1 -12.0 KB
Content
image-20230627175736-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bei
Size
... ... @@ -1,1 +1,0 @@
1 -10.4 KB
Content
image-20230627180303-6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bei
Size
... ... @@ -1,1 +1,0 @@
1 -65.1 KB
Content
image-20230628090323-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -137.2 KB
Content
image-20230628091055-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -24.9 KB
Content
image-20230628091130-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -84.0 KB
Content