Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Xiaoling on 2025/04/25 08:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -114,8 +114,6 @@ 114 114 * Sleep Mode: 5uA @ 3.3v 115 115 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 116 116 117 - 118 - 119 119 == 1.4 Connect to SDI-12 Sensor == 120 120 121 121 ... ... @@ -149,8 +149,6 @@ 149 149 ))) 150 150 |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode. 151 151 152 - 153 - 154 154 == 1.7 Pin Mapping == 155 155 156 156 ... ... @@ -361,6 +361,7 @@ 361 361 362 362 363 363 360 + 364 364 ==== (% style="color:blue" %)**aR0!- aR9!, aRC0!- aRC9!**(%%) ==== 365 365 366 366 ... ... @@ -435,7 +435,7 @@ 435 435 436 436 (% style="color:#037691" %)**1 **(%%): Delay 1 second. ( 0: 810 mini-second) 437 437 438 -(% style="color:#037691" %)**1 **(%%): 435 +(% style="color:#037691" %)**1 **(%%):Use aD0! command access. 439 439 440 440 Equal Downlink: 0xA8 03 30 4D 21 01 01 01 441 441 ... ... @@ -978,8 +978,6 @@ 978 978 979 979 * If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB. 980 980 981 - 982 - 983 983 ==== 2.6.5.2 Hardware Connection to SDI-12-LB ==== 984 984 985 985 ... ... @@ -1021,10 +1021,8 @@ 1021 1021 1022 1022 [[image:image-20230627174559-3.png]] 1023 1023 1024 - 1025 1025 ==== 2.6.4.2 Hardware Connection to SDI-12-LB ==== 1026 1026 1027 - 1028 1028 [[image:image-20230627174446-2.png]] 1029 1029 1030 1030 ... ... @@ -1041,7 +1041,6 @@ 1041 1041 1042 1042 [[image:image-20230627180303-6.png||height="292" width="1171"]] 1043 1043 1044 - 1045 1045 == 2.7 Frequency Plans == 1046 1046 1047 1047 ... ... @@ -1106,6 +1106,7 @@ 1106 1106 1107 1107 (% style="color:blue" %)**Downlink Command: 0x01** 1108 1108 1101 + 1109 1109 Format: Command Code (0x01) followed by 3 bytes time value. 1110 1110 1111 1111 If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01. ... ... @@ -1113,8 +1113,6 @@ 1113 1113 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 1114 1114 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1115 1115 1116 - 1117 - 1118 1118 == 3.2 Set Interrupt Mode == 1119 1119 1120 1120 ... ... @@ -1146,8 +1146,6 @@ 1146 1146 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 1147 1147 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1148 1148 1149 - 1150 - 1151 1151 == 3.3 Set the output time == 1152 1152 1153 1153 ... ... @@ -1219,8 +1219,6 @@ 1219 1219 * Example 5: Downlink Payload: 070301F4 **~-~-->** AT+12VT=500 1220 1220 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 1221 1221 1222 - 1223 - 1224 1224 == 3.4 Set the all data mode == 1225 1225 1226 1226 ... ... @@ -1243,8 +1243,6 @@ 1243 1243 * Example 1: Downlink Payload: AB 00 ~/~/ AT+ALLDATAMOD=0 1244 1244 * Example 2: Downlink Payload: AB 01 ~/~/ AT+ALLDATAMOD=1 1245 1245 1246 - 1247 - 1248 1248 == 3.5 Set the splicing payload for uplink == 1249 1249 1250 1250 ... ... @@ -1301,8 +1301,6 @@ 1301 1301 * Example 1: Downlink Payload: AE 01 ~/~/ AT+PAYVER=1 1302 1302 * Example 2: Downlink Payload: AE 05 ~/~/ AT+PAYVER=5 1303 1303 1304 - 1305 - 1306 1306 = 4. Battery & Power Consumption = 1307 1307 1308 1308 ... ... @@ -1389,8 +1389,6 @@ 1389 1389 * Package Size / pcs : cm 1390 1390 * Weight / pcs : g 1391 1391 1392 - 1393 - 1394 1394 = 10. Support = 1395 1395 1396 1396