Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Mengting Qiu on 2025/07/03 15:42
From version 87.3
edited by Xiaoling
on 2023/06/30 10:28
on 2023/06/30 10:28
Change comment:
There is no comment for this version
To version 81.1
edited by Bei Jinggeng
on 2023/06/27 18:03
on 2023/06/27 18:03
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -66,7 +66,6 @@ 66 66 * 8500mAh Battery for long term use 67 67 68 68 69 - 70 70 == 1.3 Specification == 71 71 72 72 ... ... @@ -79,7 +79,8 @@ 79 79 (% style="color:#037691" %)**Common DC Characteristics:** 80 80 81 81 * Supply Voltage: 2.5v ~~ 3.6v 82 -* Support current: 5V 300mA, 12V 100mA 81 +* Support current: 5V 300mA 82 + 12V 100mA 83 83 * Operating Temperature: -40 ~~ 85°C 84 84 85 85 (% style="color:#037691" %)**LoRa Spec:** ... ... @@ -115,7 +115,6 @@ 115 115 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 116 116 117 117 118 - 119 119 == 1.4 Connect to SDI-12 Sensor == 120 120 121 121 ... ... @@ -150,7 +150,6 @@ 150 150 |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode. 151 151 152 152 153 - 154 154 == 1.7 Pin Mapping == 155 155 156 156 ... ... @@ -361,6 +361,7 @@ 361 361 362 362 363 363 362 + 364 364 ==== (% style="color:blue" %)**aR0!- aR9!, aRC0!- aRC9!**(%%) ==== 365 365 366 366 ... ... @@ -429,25 +429,17 @@ 429 429 [[image:image-20230201092355-17.png||_mstalt="454337" height="426" width="1135"]] 430 430 431 431 432 -(% style="color:blue" %)**Example2: **(%%) AT+CFGDEV =0M!,1,1 431 +(% style="color:blue" %)**Example2: **(%%) AT+CFGDEV =0M!,1,1 or AT+CFGDEV =0C!,1,1 433 433 434 434 (% style="color:#037691" %)**0M! **(%%): SDI-12 Command, 435 435 436 436 (% style="color:#037691" %)**1 **(%%): Delay 1 second. ( 0: 810 mini-second) 437 437 438 -(% style="color:#037691" %)**1 **(%%): 437 +(% style="color:#037691" %)**1 **(%%):Use aD0! command access. 439 439 440 440 Equal Downlink: 0xA8 03 30 4D 21 01 01 01 441 441 442 442 443 -The following is the display information on the serial port and the server. 444 - 445 - 446 -[[image:image-20230628091055-1.png||height="368" width="462"]] 447 - 448 -[[image:image-20230628091130-2.png||height="258" width="879"]] 449 - 450 - 451 451 === 2.3.3 Convert ASCII to String === 452 452 453 453 ... ... @@ -916,7 +916,7 @@ 916 916 917 917 [[image:image-20230603121721-9.png]] 918 918 919 -[[image:image-202306 28090323-1.png||height="414" width="694"]]910 +[[image:image-20230603121752-10.png]] 920 920 921 921 Data in TTN: 922 922 ... ... @@ -979,7 +979,6 @@ 979 979 * If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB. 980 980 981 981 982 - 983 983 ==== 2.6.5.2 Hardware Connection to SDI-12-LB ==== 984 984 985 985 ... ... @@ -1021,10 +1021,8 @@ 1021 1021 1022 1022 [[image:image-20230627174559-3.png]] 1023 1023 1024 - 1025 1025 ==== 2.6.4.2 Hardware Connection to SDI-12-LB ==== 1026 1026 1027 - 1028 1028 [[image:image-20230627174446-2.png]] 1029 1029 1030 1030 ... ... @@ -1041,7 +1041,6 @@ 1041 1041 1042 1042 [[image:image-20230627180303-6.png||height="292" width="1171"]] 1043 1043 1044 - 1045 1045 == 2.7 Frequency Plans == 1046 1046 1047 1047 ... ... @@ -1106,6 +1106,7 @@ 1106 1106 1107 1107 (% style="color:blue" %)**Downlink Command: 0x01** 1108 1108 1096 + 1109 1109 Format: Command Code (0x01) followed by 3 bytes time value. 1110 1110 1111 1111 If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01. ... ... @@ -1114,7 +1114,6 @@ 1114 1114 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1115 1115 1116 1116 1117 - 1118 1118 == 3.2 Set Interrupt Mode == 1119 1119 1120 1120 ... ... @@ -1147,7 +1147,6 @@ 1147 1147 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1148 1148 1149 1149 1150 - 1151 1151 == 3.3 Set the output time == 1152 1152 1153 1153 ... ... @@ -1220,7 +1220,6 @@ 1220 1220 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 1221 1221 1222 1222 1223 - 1224 1224 == 3.4 Set the all data mode == 1225 1225 1226 1226 ... ... @@ -1244,7 +1244,6 @@ 1244 1244 * Example 2: Downlink Payload: AB 01 ~/~/ AT+ALLDATAMOD=1 1245 1245 1246 1246 1247 - 1248 1248 == 3.5 Set the splicing payload for uplink == 1249 1249 1250 1250 ... ... @@ -1302,7 +1302,6 @@ 1302 1302 * Example 2: Downlink Payload: AE 05 ~/~/ AT+PAYVER=5 1303 1303 1304 1304 1305 - 1306 1306 = 4. Battery & Power Consumption = 1307 1307 1308 1308 ... ... @@ -1390,7 +1390,6 @@ 1390 1390 * Weight / pcs : g 1391 1391 1392 1392 1393 - 1394 1394 = 10. Support = 1395 1395 1396 1396
- image-20230628090323-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Saxer - Size
-
... ... @@ -1,1 +1,0 @@ 1 -137.2 KB - Content
- image-20230628091055-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Saxer - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.9 KB - Content
- image-20230628091130-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Saxer - Size
-
... ... @@ -1,1 +1,0 @@ 1 -84.0 KB - Content