Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Xiaoling on 2025/04/25 08:58
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Saxer1 +XWiki.Xiaoling - Content
-
... ... @@ -65,6 +65,8 @@ 65 65 * Downlink to change configure 66 66 * 8500mAh Battery for long term use 67 67 68 + 69 + 68 68 == 1.3 Specification == 69 69 70 70 ... ... @@ -77,8 +77,7 @@ 77 77 (% style="color:#037691" %)**Common DC Characteristics:** 78 78 79 79 * Supply Voltage: 2.5v ~~ 3.6v 80 -* Support current: 5V 300mA 81 - 12V 100mA 82 +* Support current: 5V 300mA, 12V 100mA 82 82 * Operating Temperature: -40 ~~ 85°C 83 83 84 84 (% style="color:#037691" %)**LoRa Spec:** ... ... @@ -113,6 +113,8 @@ 113 113 * Sleep Mode: 5uA @ 3.3v 114 114 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 115 115 117 + 118 + 116 116 == 1.4 Connect to SDI-12 Sensor == 117 117 118 118 ... ... @@ -146,6 +146,8 @@ 146 146 ))) 147 147 |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode. 148 148 152 + 153 + 149 149 == 1.7 Pin Mapping == 150 150 151 151 ... ... @@ -356,7 +356,6 @@ 356 356 357 357 358 358 359 - 360 360 ==== (% style="color:blue" %)**aR0!- aR9!, aRC0!- aRC9!**(%%) ==== 361 361 362 362 ... ... @@ -431,7 +431,7 @@ 431 431 432 432 (% style="color:#037691" %)**1 **(%%): Delay 1 second. ( 0: 810 mini-second) 433 433 434 -(% style="color:#037691" %)**1 **(%%):Use aD0! command access. 438 +(% style="color:#037691" %)**1 **(%%): Use aD0! command access. 435 435 436 436 Equal Downlink: 0xA8 03 30 4D 21 01 01 01 437 437 ... ... @@ -974,6 +974,8 @@ 974 974 975 975 * If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB. 976 976 981 + 982 + 977 977 ==== 2.6.5.2 Hardware Connection to SDI-12-LB ==== 978 978 979 979 ... ... @@ -1015,8 +1015,10 @@ 1015 1015 1016 1016 [[image:image-20230627174559-3.png]] 1017 1017 1024 + 1018 1018 ==== 2.6.4.2 Hardware Connection to SDI-12-LB ==== 1019 1019 1027 + 1020 1020 [[image:image-20230627174446-2.png]] 1021 1021 1022 1022 ... ... @@ -1033,6 +1033,7 @@ 1033 1033 1034 1034 [[image:image-20230627180303-6.png||height="292" width="1171"]] 1035 1035 1044 + 1036 1036 == 2.7 Frequency Plans == 1037 1037 1038 1038 ... ... @@ -1097,7 +1097,6 @@ 1097 1097 1098 1098 (% style="color:blue" %)**Downlink Command: 0x01** 1099 1099 1100 - 1101 1101 Format: Command Code (0x01) followed by 3 bytes time value. 1102 1102 1103 1103 If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01. ... ... @@ -1105,6 +1105,8 @@ 1105 1105 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 1106 1106 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1107 1107 1116 + 1117 + 1108 1108 == 3.2 Set Interrupt Mode == 1109 1109 1110 1110 ... ... @@ -1136,6 +1136,8 @@ 1136 1136 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 1137 1137 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1138 1138 1149 + 1150 + 1139 1139 == 3.3 Set the output time == 1140 1140 1141 1141 ... ... @@ -1207,6 +1207,8 @@ 1207 1207 * Example 5: Downlink Payload: 070301F4 **~-~-->** AT+12VT=500 1208 1208 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 1209 1209 1222 + 1223 + 1210 1210 == 3.4 Set the all data mode == 1211 1211 1212 1212 ... ... @@ -1229,6 +1229,8 @@ 1229 1229 * Example 1: Downlink Payload: AB 00 ~/~/ AT+ALLDATAMOD=0 1230 1230 * Example 2: Downlink Payload: AB 01 ~/~/ AT+ALLDATAMOD=1 1231 1231 1246 + 1247 + 1232 1232 == 3.5 Set the splicing payload for uplink == 1233 1233 1234 1234 ... ... @@ -1285,6 +1285,8 @@ 1285 1285 * Example 1: Downlink Payload: AE 01 ~/~/ AT+PAYVER=1 1286 1286 * Example 2: Downlink Payload: AE 05 ~/~/ AT+PAYVER=5 1287 1287 1304 + 1305 + 1288 1288 = 4. Battery & Power Consumption = 1289 1289 1290 1290 ... ... @@ -1371,6 +1371,8 @@ 1371 1371 * Package Size / pcs : cm 1372 1372 * Weight / pcs : g 1373 1373 1392 + 1393 + 1374 1374 = 10. Support = 1375 1375 1376 1376