Last modified by Mengting Qiu on 2025/07/03 15:42

From version 87.1
edited by Saxer Lin
on 2023/06/28 09:13
Change comment: There is no comment for this version
To version 39.1
edited by Xiaoling
on 2023/02/01 14:49
Change comment: Uploaded new attachment "1675234155374-163.png", version {1}

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Saxer
1 +XWiki.Xiaoling
Content
... ... @@ -1,5 +1,5 @@
1 1  (% style="text-align:center" %)
2 -[[image:image-20230131183542-1.jpeg||_mstalt="470678" height="694" width="694"]]
2 +[[image:image-20230131183542-1.jpeg||height="694" width="694"]]
3 3  
4 4  **Table of Contents:**
5 5  
... ... @@ -17,45 +17,36 @@
17 17  
18 18  
19 19  
20 +
20 20  = 1. Introduction =
21 21  
22 22  == 1.1 ​What is SDI-12 to LoRaWAN Converter ==
23 23  
24 24  
25 -(((
26 -The Dragino (% style="color:blue" %)**SDI-12-LB**(%%) is a (% style="color:blue" %)**SDI-12 to LoRaWAN Converter **(%%)designed for Smart Agriculture solution.
27 -)))
26 +The Dragino **(% style="color:blue" %)SDI-12-LB**(%%) is a **(% style="color:blue" %)SDI-12 to LoRaWAN Converter **(%%)designed for Smart Agriculture solution.
28 28  
29 -(((
30 30  SDI-12 (Serial Digital Interface at 1200 baud) is an asynchronous [[serial communications>>url:https://en.wikipedia.org/wiki/Serial_communication]] protocol for intelligent sensors that monitor environment data. SDI-12 protocol is widely used in Agriculture sensor and Weather Station sensors.
31 -)))
32 32  
33 -(((
34 34  SDI-12-LB has SDI-12 interface and support 12v output to power external SDI-12 sensor. It can get the environment data from SDI-12 sensor and sends out the data via LoRaWAN wireless protocol.
35 -)))
36 36  
37 -(((
38 38  The LoRa wireless technology used in SDI-12-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
39 -)))
40 40  
41 -(((
42 -SDI-12-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
43 -)))
34 +SDI-12-LB is powered by **(% style="color:blue" %)8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
44 44  
45 -(((
46 46  Each SDI-12-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
47 -)))
48 48  
49 49  
50 -[[image:image-20230201084414-1.png||_mstalt="427765" height="464" width="1108"]]
39 +[[image:image-20230201084414-1.png||height="464" width="1108"]]
51 51  
52 52  
42 +
43 +
53 53  == ​1.2 Features ==
54 54  
55 55  
56 56  * LoRaWAN 1.0.3 Class A
57 57  * Ultra-low power consumption
58 -* Controllable 3.3v, 5v and 12v output to power external sensor
49 +* Controllable 5v and 12v output to power external sensor
59 59  * SDI-12 Protocol to connect to SDI-12 Sensor
60 60  * Monitor Battery Level
61 61  * Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865
... ... @@ -65,23 +65,22 @@
65 65  * Downlink to change configure
66 66  * 8500mAh Battery for long term use
67 67  
59 +
68 68  == 1.3 Specification ==
69 69  
70 70  
71 -(% style="color:#037691" %)**Micro Controller:**
63 +**(% style="color:#037691" %)Micro Controller:**
72 72  
73 73  * MCU: 48Mhz ARM
74 74  * Flash: 256KB
75 75  * RAM: 64KB
76 76  
77 -(% style="color:#037691" %)**Common DC Characteristics:**
69 +**(% style="color:#037691" %)Common DC Characteristics:**
78 78  
79 79  * Supply Voltage: 2.5v ~~ 3.6v
80 -* Support current: 5V 300mA
81 - 12V 100mA
82 82  * Operating Temperature: -40 ~~ 85°C
83 83  
84 -(% style="color:#037691" %)**LoRa Spec:**
74 +**(% style="color:#037691" %)LoRa Spec:**
85 85  
86 86  * Frequency Range,  Band 1 (HF): 862 ~~ 1020 Mhz
87 87  * Max +22 dBm constant RF output vs.
... ... @@ -88,19 +88,19 @@
88 88  * RX sensitivity: down to -139 dBm.
89 89  * Excellent blocking immunity
90 90  
91 -(% style="color:#037691" %)**Current Input Measuring :**
81 +**(% style="color:#037691" %)Current Input Measuring :**
92 92  
93 93  * Range: 0 ~~ 20mA
94 94  * Accuracy: 0.02mA
95 95  * Resolution: 0.001mA
96 96  
97 -(% style="color:#037691" %)**Voltage Input Measuring:**
87 +**(% style="color:#037691" %)Voltage Input Measuring:**
98 98  
99 99  * Range: 0 ~~ 30v
100 100  * Accuracy: 0.02v
101 101  * Resolution: 0.001v
102 102  
103 -(% style="color:#037691" %)**Battery:**
93 +**(% style="color:#037691" %)Battery:**
104 104  
105 105  * Li/SOCI2 un-chargeable battery
106 106  * Capacity: 8500mAh
... ... @@ -108,48 +108,52 @@
108 108  * Max continuously current: 130mA
109 109  * Max boost current: 2A, 1 second
110 110  
111 -(% style="color:#037691" %)**Power Consumption**
101 +**(% style="color:#037691" %)Power Consumption**
112 112  
113 113  * Sleep Mode: 5uA @ 3.3v
114 114  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
115 115  
106 +
116 116  == 1.4 Connect to SDI-12 Sensor ==
117 117  
118 118  
119 -[[image:1675212538524-889.png||_mstalt="298272"]]
120 120  
111 +[[image:1675212538524-889.png]]
121 121  
113 +
122 122  == 1.5 Sleep mode and working mode ==
123 123  
124 124  
125 -(% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life.
117 +**(% style="color:blue" %)Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life.
126 126  
127 -(% style="color:blue" %)**Working Mode: **(%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode.
119 +**(% style="color:blue" %)Working Mode: **(%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode.
128 128  
129 129  
130 130  == 1.6 Button & LEDs ==
131 131  
132 132  
133 -[[image:1675212633011-651.png||_mstalt="291538"]]
125 +[[image:1675212633011-651.png]]
134 134  
135 135  
136 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
137 -|=(% style="width: 167px;background-color:#D9E2F3;color:#0070C0" %)**Behavior on ACT**|=(% style="width: 117px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 225px;background-color:#D9E2F3;color:#0070C0" %)**Action**
138 -|(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT between 1s < time < 3s|(% style="background-color:#f2f2f2; width:117px" %)Send an uplink|(% style="background-color:#f2f2f2; width:225px" %)(((
128 +
129 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
130 +|=(% style="width: 167px;" %)**Behavior on ACT**|=(% style="width: 117px;" %)**Function**|=(% style="width: 225px;" %)**Action**
131 +|(% style="width:167px" %)Pressing ACT between 1s < time < 3s|(% style="width:117px" %)Send an uplink|(% style="width:225px" %)(((
139 139  If sensor is already Joined to LoRaWAN network, sensor will send an uplink packet, (% style="color:blue" %)**blue led** (%%)will blink once.
140 140  Meanwhile, BLE module will be active and user can connect via BLE to configure device.
141 141  )))
142 -|(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT for more than 3s|(% style="background-color:#f2f2f2; width:117px" %)Active Device|(% style="background-color:#f2f2f2; width:225px" %)(((
143 -(% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:#037691" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network.
144 -(% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network.
135 +|(% style="width:167px" %)Pressing ACT for more than 3s|(% style="width:117px" %)Active Device|(% style="width:225px" %)(((
136 +(% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:#037691" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network.
137 +(% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network.
145 145  Once sensor is active, BLE module will be active and user can connect via BLE to configure device, no matter if device join or not join LoRaWAN network.
146 146  )))
147 -|(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode.
140 +|(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode.
148 148  
142 +
149 149  == 1.7 Pin Mapping ==
150 150  
151 151  
152 -[[image:1675213198663-754.png||_mstalt="297167"]]
146 +[[image:1675213198663-754.png]]
153 153  
154 154  
155 155  == 1.8 BLE connection ==
... ... @@ -169,11 +169,11 @@
169 169  == 1.9 Mechanical ==
170 170  
171 171  
172 -[[image:image-20230201090139-2.png||_mstalt="428623"]]
166 +[[image:image-20230201090139-2.png]]
173 173  
174 -[[image:image-20230201090139-3.png||_mstalt="428987"]]
168 +[[image:image-20230201090139-3.png]]
175 175  
176 -[[image:image-20230201090139-4.png||_mstalt="429351"]]
170 +[[image:image-20230201090139-4.png]]
177 177  
178 178  
179 179  = 2. Configure SDI-12 to connect to LoRaWAN network =
... ... @@ -181,7 +181,7 @@
181 181  == 2.1 How it works ==
182 182  
183 183  
184 -The SDI-12-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and activate the SDI-12-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
178 +The SDI-12-LB is configured as **(% style="color:#037691" %)LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and activate the SDI-12-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
185 185  
186 186  
187 187  == 2.2 Quick guide to connect to LoRaWAN server (OTAA) ==
... ... @@ -190,55 +190,60 @@
190 190  Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LPS8v2>>url:https://www.dragino.com/products/lora-lorawan-gateway/item/228-lps8v2.html]] as a LoRaWAN gateway in this example.
191 191  
192 192  
193 -[[image:image-20230201090528-5.png||_mstalt="430300" height="465" width="1111"]]
187 +[[image:image-20230201090528-5.png||height="465" width="1111"]]
194 194  
195 195  
196 196  The LPS8V2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
197 197  
198 198  
199 -(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from SDI-12-LB.
193 +**(% style="color:blue" %)Step 1**(%%): Create a device in TTN with the OTAA keys from SDI-12-LB.
200 200  
201 201  Each SDI-12-LB is shipped with a sticker with the default device EUI as below:
202 202  
203 -[[image:image-20230426084456-1.png||height="241" width="519"]]
204 204  
198 +[[image:image-20230131134744-2.jpeg]]
205 205  
200 +
201 +
202 +
203 +
206 206  You can enter this key in the LoRaWAN Server portal. Below is TTN screen shot:
207 207  
208 208  
209 -(% style="color:blue" %)**Register the device**
207 +**(% style="color:blue" %)Register the device**
210 210  
211 -[[image:1675213652444-622.png||_mstalt="293657"]]
209 +[[image:1675213652444-622.png]]
212 212  
213 213  
214 -(% style="color:blue" %)**Add APP EUI and DEV EUI**
212 +**(% style="color:blue" %)Add APP EUI and DEV EUI**
215 215  
216 216  
217 -[[image:1675213661769-223.png||_mstalt="295217"]]
215 +[[image:1675213661769-223.png]]
218 218  
219 219  
220 -(% style="color:blue" %)**Add APP EUI in the application**
218 +**(% style="color:blue" %)Add APP EUI in the application**
221 221  
222 222  
223 -[[image:1675213675852-577.png||_mstalt="297947"]]
221 +[[image:1675213675852-577.png]]
224 224  
225 225  
226 -(% style="color:blue" %)**Add APP KEY**
224 +**(% style="color:blue" %)Add APP KEY**
227 227  
228 -[[image:1675213686734-883.png||_mstalt="298064"]]
226 +[[image:1675213686734-883.png]]
229 229  
230 230  
231 -(% style="color:blue" %)**Step 2**(%%): Activate on SDI-12-LB
229 +**(% style="color:blue" %)Step 2**(%%): Activate on SDI-12-LB
232 232  
233 233  
234 234  Press the button for 5 seconds to activate the SDI-12-LB.
235 235  
236 -(% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode** (%%)for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network.
237 237  
235 +**(% style="color:green" %)Green led**(%%) will fast blink 5 times, device will enter **(% style="color:blue" %)OTA mode** (%%)for 3 seconds. And then start to JOIN LoRaWAN network. **(% style="color:green" %)Green led**(%%) will solidly turn on for 5 seconds after joined in network.
238 238  
239 -[[image:1675213704414-644.png||_mstalt="293748"]]
240 240  
238 +[[image:1675213704414-644.png]]
241 241  
240 +
242 242  == ​2.3 SDI-12 Related Commands ==
243 243  
244 244  
... ... @@ -255,43 +255,43 @@
255 255  The following is the display information on the serial port and the server.
256 256  
257 257  
258 -[[image:image-20230201091027-6.png||_mstalt="429065"]]
259 259  
258 +[[image:image-20230201091027-6.png]]
260 260  
261 -[[image:image-20230201091027-7.png||_mstalt="429429" height="261" width="1179"]]
262 262  
261 +[[image:image-20230201091027-7.png||height="261" width="1179"]]
263 263  
264 264  
265 -==== (% style="color:blue" %)**al!  ~-~- Get SDI-12 sensor Identification**(%%) ====
264 +==== **(% style="color:blue" %)al!  ~-~- Get SDI-12 sensor Identification** ====
266 266  
267 267  
268 268  * AT Command: AT+ADDRI=aa
269 269  * LoRaWAN Downlink(prefix 0xAA00): AA 00 aa
270 270  
271 -(% style="color:#037691" %)**Parameter:  **(%%)aa: ASCII value of SDI-12 sensor address in downlink or HEX value in AT Command)
270 +**(% style="color:#037691" %)Parameter:  **(%%)aa: ASCII value of SDI-12 sensor address in downlink or HEX value in AT Command)
272 272  
273 -(% style="color:blue" %)**Example :   **(%%)AT+ADDRI=0 ( Equal to downlink: 0x AA 00 30)
272 +**(% style="color:blue" %)Example :   **AT+ADDRI=0 ( Equal to downlink: 0x AA 00 30)
274 274  
275 275  
276 276  The following is the display information on the serial port and the server.
277 277  
278 278  
279 -[[image:image-20230201091257-8.png||_mstalt="431392"]]
278 +[[image:image-20230201091257-8.png]]
280 280  
281 281  
282 -[[image:image-20230201091257-9.png||_mstalt="431756" height="225" width="1242"]]
281 +[[image:image-20230201091257-9.png||height="225" width="1242"]]
283 283  
284 284  
285 -==== (% style="color:blue" %)**aM!,aMC!, aM1!- aM9!, aMC1!- aMC9!**(%%) ====
284 +==== **(% style="color:blue" %)aM!,aMC!, aM1!- aM9!, aMC1!- aMC9!** ====
286 286  
287 287  
288 -(% style="color:red" %)**aM! **(%%): Start Non-Concurrent Measurement
287 +**(% style="color:red" %)aM! **(%%): Start Non-Concurrent Measurement
289 289  
290 -(% style="color:red" %)**aMC! **(%%): Start Non-Concurrent Measurement – Request CRC
289 +**(% style="color:red" %)aMC! **(%%): Start Non-Concurrent Measurement – Request CRC
291 291  
292 -(% style="color:red" %)**aM1!- aM9! **(%%): Additional Measurements
291 +**(% style="color:red" %)aM1!- aM9! **(%%): Additional Measurements
293 293  
294 -(% style="color:red" %)**aMC1!- aMC9!**(%%) : Additional Measurements – Request CRC
293 +**(% style="color:red" %)aMC1!- aMC9!**(%%) : Additional Measurements – Request CRC
295 295  
296 296  
297 297  * AT Command : AT+ADDRM=0,1,0,1
... ... @@ -300,35 +300,35 @@
300 300  
301 301  Downlink:AA 01 aa bb cc dd
302 302  
303 -(% style="color:#037691" %)**aa**(%%): SDI-12 sensor address.
302 +**(% style="color:#037691" %)aa**(%%): SDI-12 sensor address.
304 304  
305 -(% style="color:#037691" %)**bb**(%%): 0: no CRC, 1: request CRC
304 +**(% style="color:#037691" %)bb**(%%): 0: no CRC, 1: request CRC
306 306  
307 -(% style="color:#037691" %)**cc**(%%): 1-9: Additional Measurement, 0: no additional measurement
306 +**(% style="color:#037691" %)cc**(%%): 1-9: Additional Measurement, 0: no additional measurement
308 308  
309 -(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)__**aD0!**__(%%) to get return.
308 +**(% style="color:#037691" %)dd**(%%): delay (in second) to send **(% style="color:#037691" %)aD0!**(%%) to get return.
310 310  
311 311  
312 312  The following is the display information on the serial port and the server.
313 313  
314 314  
315 -[[image:image-20230201091630-10.png||_mstalt="449995"]]
314 +[[image:image-20230201091630-10.png]]
316 316  
317 317  
318 -[[image:image-20230201091630-11.png||_mstalt="450372" height="247" width="1165"]]
317 +[[image:image-20230201091630-11.png||height="247" width="1165"]]
319 319  
320 320  
321 321  
322 -==== (% style="color:blue" %)**aC!, aCC!,  aC1!- aC9!,  aCC1!- aCC9! **(%%) ====
321 +==== **(% style="color:blue" %)aC!, aCC!,  aC1!- aC9!,  aCC1!- aCC9! ** ====
323 323  
324 324  
325 -(% style="color:red" %)**aC!**(%%) : Start Concurrent Measurement
324 +**(% style="color:red" %)aC!**(%%) : Start Concurrent Measurement
326 326  
327 -(% style="color:red" %)**aCC!** (%%): Start Concurrent Measurement – Request CRC
326 +**(% style="color:red" %)aCC!** (%%): Start Concurrent Measurement – Request CRC
328 328  
329 -(% style="color:red" %)**aC1!- aC9!**(%%) : Start Additional Concurrent Measurements
328 +**(% style="color:red" %)aC1!- aC9!**(%%) : Start Additional Concurrent Measurements
330 330  
331 -(% style="color:red" %)**aCC1!- aCC9!**(%%) : Start Additional Concurrent Measurements – Request CRC
330 +**(% style="color:red" %)aCC1!- aCC9!**(%%) : Start Additional Concurrent Measurements – Request CRC
332 332  
333 333  
334 334  * AT Command : AT+ADDRC=0,1,0,1 
... ... @@ -337,27 +337,27 @@
337 337  
338 338  Downlink: AA 02 aa bb cc dd
339 339  
340 -(% style="color:#037691" %)**aa**(%%): SDI-12 sensor address.
339 +**(% style="color:#037691" %)aa**(%%): SDI-12 sensor address.
341 341  
342 -(% style="color:#037691" %)**bb**(%%): 0: no CRC, 1: request CRC
341 +**(% style="color:#037691" %)bb**(%%): 0: no CRC, 1: request CRC
343 343  
344 -(% style="color:#037691" %)**cc**(%%): 1-9: Additional Measurement, 0: no additional measurement
343 +**(% style="color:#037691" %)cc**(%%): 1-9: Additional Measurement, 0: no additional measurement
345 345  
346 -(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)__**aD0!**__(%%)__ __to get return.
345 +**(% style="color:#037691" %)dd**(%%): delay (in second) to send **(% style="color:#037691" %)aD0!**(%%) to get return.
347 347  
348 348  
349 349  The following is the display information on the serial port and the server.
350 350  
351 351  
352 -[[image:image-20230201091954-12.png||_mstalt="453687"]]
351 +[[image:image-20230201091954-12.png]]
353 353  
354 354  
355 -[[image:image-20230201091954-13.png||_mstalt="454064" height="203" width="1117"]]
354 +[[image:image-20230201091954-13.png||height="203" width="1117"]]
356 356  
357 357  
358 358  
359 359  
360 -==== (% style="color:blue" %)**aR0!- aR9!,  aRC0!- aRC9!**(%%) ====
359 +==== **(% style="color:blue" %)aR0!- aR9!,  aRC0!- aRC9!** ====
361 361  
362 362  
363 363  Start Continuous Measurement
... ... @@ -370,24 +370,25 @@
370 370  
371 371  Downlink: AA 03 aa bb cc dd
372 372  
373 -(% style="color:#037691" %)**aa**(%%): SDI-12 sensor address.
372 +**(% style="color:#037691" %)aa**(%%): SDI-12 sensor address.
374 374  
375 -(% style="color:#037691" %)**bb**(%%): 0: no CRC, 1: request CRC
374 +**(% style="color:#037691" %)bb**(%%): 0: no CRC, 1: request CRC
376 376  
377 -(% style="color:#037691" %)**cc**(%%): 1-9: Additional Measurement, 0: no additional measurement
376 +**(% style="color:#037691" %)cc**(%%): 1-9: Additional Measurement, 0: no additional measurement
378 378  
379 -(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)__**aD0!**__(%%) to get return.
378 +**(% style="color:#037691" %)dd**(%%): delay (in second) to send **(% style="color:#037691" %)aD0!**(%%) to get return.
380 380  
381 381  
382 382  The following is the display information on the serial port and the server.
383 383  
384 384  
385 -[[image:image-20230201092208-14.png||_mstalt="452283"]]
386 386  
385 +[[image:image-20230201092208-14.png]]
387 387  
388 -[[image:image-20230201092208-15.png||_mstalt="452660" height="214" width="1140"]]
389 389  
388 +[[image:image-20230201092208-15.png||height="214" width="1140"]]
390 390  
390 +
391 391  === 2.3.2 Advance SDI-12 Debug command ===
392 392  
393 393  
... ... @@ -394,25 +394,23 @@
394 394  This command can be used to debug all SDI-12 command.
395 395  
396 396  
397 -LoRaWAN Downlink: A8 aa xx xx xx xx bb cc dd
397 +LoRaWAN Downlink: A8 aa xx xx xx xx bb cc
398 398  
399 -(% style="color:#037691" %)**aa **(%%): total SDI-12 command length
399 +**(% style="color:#037691" %)aa **(%%): total SDI-12 command length
400 400  
401 -(% style="color:#037691" %)**xx **(%%): SDI-12 command
401 +**(% style="color:#037691" %)xx **(%%): SDI-12 command
402 402  
403 -(% style="color:#037691" %)**bb **(%%): Delay to wait for return
403 +**(% style="color:#037691" %)bb **(%%): Delay to wait for return
404 404  
405 -(% style="color:#037691" %)**cc **(%%): 0: don't uplink return to LoRaWAN, 1: Uplink return to LoRaWAN on FPORT=100
405 +**(% style="color:#037691" %)cc **(%%): 0: don't uplink return to LoRaWAN, 1: Uplink return to LoRaWAN on FPORT=100
406 406  
407 -(% style="color:#037691" %)**dd: **(%%) 0: Do not use aD0! command access, 1: use aD0! command access.
408 408  
408 +**(% style="color:blue" %)Example: **(%%) AT+CFGDEV =0RC0!,1
409 409  
410 -(% style="color:blue" %)**Example1: **(%%) AT+CFGDEV =0RC0!,1
410 +**(% style="color:#037691" %)0RC0! **(%%): SDI-12 Command,
411 411  
412 -(% style="color:#037691" %)**0RC0! **(%%): SDI-12 Command,
412 +**(% style="color:#037691" %)1 **(%%): Delay 1 second.  ( 0: 810 mini-second)
413 413  
414 -(% style="color:#037691" %)**1 **(%%): Delay 1 second.  ( 0: 810 mini-second)
415 -
416 416  Equal Downlink: 0xA8 05 30 52 43 30 21 01 01
417 417  
418 418  
... ... @@ -419,31 +419,12 @@
419 419  The following is the display information on the serial port and the server.
420 420  
421 421  
422 -[[image:image-20230201092355-16.png||_mstalt="453960"]]
420 +[[image:image-20230201092355-16.png]]
423 423  
424 424  
425 -[[image:image-20230201092355-17.png||_mstalt="454337" height="426" width="1135"]]
423 +[[image:image-20230201092355-17.png||height="426" width="1135"]]
426 426  
427 427  
428 -(% style="color:blue" %)**Example2: **(%%) AT+CFGDEV =0M!,1,1
429 -
430 -(% style="color:#037691" %)**0M! **(%%): SDI-12 Command,
431 -
432 -(% style="color:#037691" %)**1 **(%%): Delay 1 second.  ( 0: 810 mini-second)
433 -
434 -(% style="color:#037691" %)**1 **(%%):Use aD0! command access.
435 -
436 -Equal Downlink: 0xA8 03 30  4D 21 01 01 01
437 -
438 -
439 -The following is the display information on the serial port and the server.
440 -
441 -
442 -[[image:image-20230628091055-1.png||height="368" width="462"]]
443 -
444 -[[image:image-20230628091130-2.png||height="258" width="879"]]
445 -
446 -
447 447  === 2.3.3 Convert ASCII to String ===
448 448  
449 449  
... ... @@ -452,16 +452,16 @@
452 452  AT+CONVFORM ( Max length: 80 bytes)
453 453  
454 454  
455 -(% style="color:blue" %)**Example:**
434 +**(% style="color:blue" %)Example:**
456 456  
457 457  1) AT+CONVFORM=0, string Convert String from String to ASCII
458 458  
459 -[[image:1675214845056-885.png||_mstalt="297622"]]
438 +[[image:1675214845056-885.png]]
460 460  
461 461  
462 462  2) AT+CONVFORM=1, ASCII Convert ASCII to String.
463 463  
464 -[[image:1675214856590-846.png||_mstalt="297739"]]
443 +[[image:1675214856590-846.png]]
465 465  
466 466  
467 467  === 2.3.4 Define periodically SDI-12 commands and uplink. ===
... ... @@ -472,35 +472,35 @@
472 472  User can define max 15 SDI-12 Commands (AT+COMMAND1 ~~ AT+COMMANDF). On each uplink period (TDC time, default 20 minutes), SDI-12-LB will send these SDI-12 commands and wait for return from SDI-12 sensors. SDI-12-LB will then combine these returns and uplink via LoRaWAN.
473 473  
474 474  
475 -* (% style="color:blue" %)**AT Command:**
454 +* ** (% style="color:blue" %)AT Command:**
476 476  
477 -(% style="color:#037691" %)**AT+COMMANDx=var1,var2,var3,var4.**
456 +**(% style="color:#037691" %)AT+COMMANDx=var1,var2,var3,var4.**
478 478  
479 -(% style="color:red" %)**var1**(%%): SDI-12 command , for example: 0RC0!
458 +**(% style="color:red" %)var1**(%%): SDI-12 command , for example: 0RC0!
480 480  
481 -(% style="color:red" %)**var2**(%%): Wait timeout for return. (unit: second)
460 +**(% style="color:red" %)var2**(%%): Wait timeout for return. (unit: second)
482 482  
483 -(% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//.
462 +**(% style="color:red" %)var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//.
484 484  
485 -(% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB will resend this command. Max 3 retries.
464 +**(% style="color:red" %)var4**(%%): validation check for return. If return invalid, SDI-12-LB will resend this command. Max 2 retries.
486 486  
487 -(% style="color:red" %)**0 **(%%) No validation check;
466 +**(% style="color:red" %)0 **(%%) No validation check;
488 488  
489 -(% style="color:red" %)**1** (%%) Check if return chars are printable char(0x20 ~~ 0x7E);
468 +**(% style="color:red" %)1** (%%) Check if return chars are printable char(0x20 ~~ 0x7E);
490 490  
491 -(% style="color:red" %)**2**(%%)  Check if there is return from SDI-12 sensor
470 +**(% style="color:#red" %)2**(%%)  Check if there is return from SDI-12 sensor
492 492  
493 -(% style="color:red" %)**3** (%%) Check if return pass CRC check ( SDI-12 command var1 must include CRC request);
472 +**(% style="color:red" %)3** (%%) Check if return pass CRC check ( SDI-12 command var1 must include CRC request);
494 494  
495 495  
496 -Each AT+COMMANDx is followed by a (% style="color:blue" %)**AT+DATACUT**(%%) command. AT+DATACUT command is used to take the useful string from the SDI-12 sensor so the final payload will have the minimum length to uplink.
475 +Each AT+COMMANDx is followed by a **(% style="color:blue" %)AT+DATACUT**(%%) command. AT+DATACUT command is used to take the useful string from the SDI-12 sensor so the final payload will have the minimum length to uplink.
497 497  
498 498  
499 -(% style="color:blue" %)**AT+DATACUTx**(%%) : This command defines how to handle the return from AT+COMMANDx, max return length is 100 bytes.
478 +**(% style="color:blue" %)AT+DATACUTx**(%%) : This command defines how to handle the return from AT+COMMANDx, max return length is 100 bytes.
500 500  
501 -(% border="1" style="width:436px" %)
502 -|(% style="background-color:#f2f2f2; width:433px" %)(((
503 -(% style="color:#0070c0" %)**AT+DATACUTx=a,b,c**
480 +(% border="1" style="background-color:#f7faff; width:436px" %)
481 +|(% style="width:433px" %)(((
482 +**AT+DATACUTx=a,b,c**
504 504  
505 505  **a**:  length for the return of AT+COMMAND
506 506  
... ... @@ -509,100 +509,102 @@
509 509  **c**:  define the position for valid value. 
510 510  )))
511 511  
512 -For example, if return from AT+COMMAND1 is “013METER   TER12 112T12-00024895<CR><LF>” , Below AT+DATACUT1 will get different result to combine payload:
491 +For example, if return from AT+COMMAND1 is “013METER   TER12 112T12-00024895” , Below AT+DATACUT1 will get different result to combine payload:
513 513  
514 514  
515 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
516 -|=(% style="width: 164px;background-color:#D9E2F3;color:#0070C0" %)**AT+DATACUT1 value**|=(% style="width: 344px;background-color:#D9E2F3;color:#0070C0" %)**Final Result to combine Payload**
517 -|(% style="background-color:#f2f2f2; width:164px" %)34,1,1+2+3|(% style="background-color:#f2f2f2; width:344px" %)0D 00 01 30 31 33
518 -|(% style="background-color:#f2f2f2; width:164px" %)34,2,1~~8+12~~16|(% style="background-color:#f2f2f2; width:344px" %)0D 00 01 30 31 33 4D 45 54 45 52 54 45 52 31 32
519 -|(% style="background-color:#f2f2f2; width:164px" %)34,2,1~~34|(% style="background-color:#f2f2f2; width:344px" %)0D 00 01 30 31 33 4D 45 54 45 52 20 20 20 54 45 52 31 32 20 31 31 32 54 31 32 2D 30 30 30 32 34 38 39 35 0D 0A
494 +(% border="1" cellspacing="4" style="background-color:#f7faff; width:510px" %)
495 +|(% style="width:170px" %)**AT+DATACUT1 value**|(% style="width:338px" %)**Final Result to combine Payload**
496 +|(% style="width:170px" %)34,1,1+2+3|(% style="width:338px" %)0D 00 01 30 31 33
497 +|(% style="width:170px" %)34,2,1~~8+12~~16|(% style="width:338px" %)0D 00 01 30 31 33 4D 45 54 45 52 54 45 52 31 32
498 +|(% style="width:170px" %)34,2,1~~34|(% style="width:338px" %)0D 00 01 30 31 33 4D 45 54 45 52 20 20 20 54 45 52 31 32 20 31 31 32 54 31 32 2D 30 30 30 32 34 38 39 35 0D 0A
520 520  
521 -* (% style="color:blue" %)** Downlink Payload:**
500 +* **(% style="color:blue" %) Downlink Payload:**
522 522  
523 -(% style="color:blue" %)**0xAF**(%%)  downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
502 +**(% style="color:blue" %)0xAF**(%%)  downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
524 524  
525 525  
526 -(% style="color:red" %)**Note : if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.**
505 +**(% style="color:red" %)Note : if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.**
527 527  
528 528  
529 -Format: ** (% style="color:#037691" %)AF MM NN LL XX XX XX XX YY(%%)**
508 +Format: ** (% style="color:#037691" %)AF MM NN LL XX XX XX XX YY**
530 530  
531 531  Where:
532 532  
533 -* (% style="color:#037691" %)**MM **(%%): the AT+COMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
534 -* (% style="color:#037691" %)**NN **(%%):  1: set the AT+COMMAND value ; 2: set the AT+DATACUT value.
535 -* (% style="color:#037691" %)**LL **(%%):  The length of AT+COMMAND or AT+DATACUT command
536 -* (% style="color:#037691" %)**XX XX XX XX **(%%): AT+COMMAND or AT+DATACUT command
537 -* (% style="color:#037691" %)**YY **(%%):  If YY=0, SDI-12-LB will execute the downlink command without uplink; if YY=1, SDI-12-LB will execute an uplink after got this command. 
512 +* **(% style="color:#037691" %)MM **(%%): the AT+COMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
513 +* **(% style="color:#037691" %)NN **(%%):  1: set the AT+DATACUT value ; 2: set the AT+DATACUT value.
514 +* **(% style="color:#037691" %)LL **(%%):  The length of AT+COMMAND or AT+DATACUT command
515 +* **(% style="color:#037691" %)XX XX XX XX **(%%): AT+COMMAND or AT+DATACUT command
516 +* **(% style="color:#037691" %)YY **(%%):  If YY=0, RS485-LN will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command. 
538 538  
539 -(% style="color:blue" %)**Example:**
518 +**(% style="color:blue" %)Example:**
540 540  
541 -[[image:image-20230201094129-18.png||_mstalt="455065"]]
520 +[[image:image-20230201094129-18.png]]
542 542  
543 543  
523 +**(% style="color:blue" %)Clear SDI12 Command**
544 544  
545 -(% style="color:blue" %)**Clear SDI12 Command**
546 -
547 547  The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
548 548  
549 549  
550 -* (% style="color:#037691" %)**AT Command:**
528 +* ** (% style="color:#037691" %)AT Command:**
551 551  
552 -(% style="color:#4f81bd" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase
530 +**(% style="color:#4F81BD" %)AT+CMDEAR=mm,nn** (%%)  mm: start position of erase ,nn: stop position of erase
553 553  
554 554  
555 555  Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
556 556  
557 557  
558 -* (% style="color:#037691" %)** Downlink Payload:**
536 +* **(% style="color:#037691" %) Downlink Payload:**
559 559  
560 -(% style="color:#4f81bd" %)**0x09 aa bb**(%%)  same as AT+CMDEAR=aa,bb
538 +**(% style="color:#4F81BD" %)0x09 aa bb**(%%)  same as AT+CMDEAR=aa,bb
561 561  
562 562  
563 563  
564 -(% style="color:blue" %)**command combination**
542 +**(% style="color:blue" %)command combination**
565 565  
566 566  Below shows a screen shot how the results combines together to a uplink payload.
567 567  
568 -[[image:1675215745275-920.png||_mstalt="295334"]]
546 +[[image:1675215745275-920.png]]
569 569  
570 570  
571 571  If user don't want to use DATACUT for some command, he simply want to uplink all returns. AT+ALLDATAMOD can be set to 1.
572 572  
573 -(% style="color:blue" %)**AT+ALLDATAMOD**(%%) will simply get all return and don't do CRC check as result for SDI-12 command. AT+DATACUTx command has higher priority, if AT+DATACUTx has been set, AT+ALLDATAMOD will be ignore for this SDI-12 command.
551 +**(% style="color:blue" %)AT+ALLDATAMOD**(%%) will simply get all return and don't do CRC check as result for SDI-12 command. AT+DATACUTx command has higher priority, if AT+DATACUTx has been set, AT+ALLDATAMOD will be ignore for this SDI-12 command.
574 574  
575 575  
576 -(% style="color:#4f81bd" %)**For example: **(%%) as below photo, AT+ALLDATAMOD=1, but AT+DATACUT1 has been set, AT+DATACUT1 will be still effect the result.
554 +**(% style="color:#4F81BD" %)For example: ** as below photo, AT+ALLDATAMOD=1, but AT+DATACUT1 has been set, AT+DATACUT1 will be still effect the result.
577 577  
578 578  
579 -[[image:1675215782925-448.png||_mstalt="297466"]]
557 +[[image:1675215782925-448.png]]
580 580  
581 581  
582 -If AT+ALLDATAMOD=1, (% style="color:#4f81bd" %)**FX,X**(%%) will be added in the payload, FX specify which command is used and X specify the length of return. for example in above screen, F1 05 means the return is from AT+COMMAND1 and the return is 5 bytes.
560 +If AT+ALLDATAMOD=1, **(% style="color:#4F81BD" %)FX,X**(%%) will be added in the payload, FX specify which command is used and X specify the length of return. for example in above screen, F1 05 means the return is from AT+COMMAND1 and the return is 5 bytes.
583 583  
584 584  
585 585  
586 -(% style="color:blue" %)**Compose Uplink**
564 +**(% style="color:blue" %)Compose Uplink**
587 587  
588 -(% style="color:#4f81bd" %)**AT+DATAUP=0**
589 589  
590 -Compose the uplink payload with value returns in sequence and send with **__A SIGNLE UPLINK__**.
567 +**(% style="color:#4F81BD" %)AT+DATAUP=0**
591 591  
592 -Final Payload is **__Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx__**
569 +Compose the uplink payload with value returns in sequence and send with A SIGNLE UPLINK.
593 593  
571 +Final Payload is Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx
572 +
594 594  Where PAYVER is defined by AT+PAYVER, below is an example screen shot.
595 595  
596 596  
597 -[[image:1675215828102-844.png||_mstalt="294645"]]
576 +[[image:1675215828102-844.png]]
598 598  
599 599  
600 -(% style="color:#4f81bd" %)**AT+DATAUP=1**
579 +**(% style="color:#4F81BD" %)AT+DATAUP=1**
601 601  
602 -Compose the uplink payload with value returns in sequence and send with **__Multiply UPLINKs__**.
581 +Compose the uplink payload with value returns in sequence and send with Multiply UPLINKs.
603 603  
604 -Final Payload is __**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**__
583 +Final Payload is
605 605  
585 +__**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**__
586 +
606 606  1. Battery Info (2 bytes): Battery voltage
607 607  1. PAYVER (1 byte): Defined by AT+PAYVER
608 608  1. PAYLOAD COUNT (1 byte): Total how many uplinks of this sampling.
... ... @@ -609,10 +609,10 @@
609 609  1. PAYLOAD# (1 byte): Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
610 610  1. DATA: Valid value: max 6 bytes(US915 version here, Notice*!) for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 6 bytes
611 611  
612 -[[image:1675215848113-696.png||_mstalt="296998"]]
593 +[[image:1675215848113-696.png]]
613 613  
614 614  
615 -(% style="color:red" %)**Notice: the Max bytes is according to the max support bytes in different Frequency Bands for lowest SF. As below:**
596 +**(% style="color:red" %)Notice: the Max bytes is according to the max support bytes in different Frequency Bands for lowest SF. As below:**
616 616  
617 617  * For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink ( so 51 -5 = 46 max valid date)
618 618  * For AU915/AS923 bands, if UplinkDwell time=1, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date).
... ... @@ -619,13 +619,22 @@
619 619  * For US915 band, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date).
620 620  * For all other bands: max 51 bytes for each uplink  ( so 51 -5 = 46 max valid date).
621 621  
622 -(% style="color:red" %)**When AT+DATAUP=1, the maximum number of segments is 15, and the maximum total number of bytes is 1500;**
603 +**(% style="color:red" %)When AT+DATAUP=1, the maximum number of segments is 15, and the maximum total number of bytes is 1500;**
623 623  
624 -(% style="color:red" %)**When AT+DATAUP=1 and AT+ADR=0, the maximum number of bytes of each payload is determined by the DR value.**
605 +**(% style="color:red" %)When AT+DATAUP=1 and AT+ADR=0, the maximum number of bytes of each payload is determined by the DR value.**
625 625  
626 626  
627 -== 2.4 Uplink Payload ==
608 +== ​​​​​​​2.4 Uplink Payload ==
628 628  
610 +
611 +Uplink payloads have two types:
612 +
613 +* Distance Value: Use FPORT=2
614 +* Other control commands: Use other FPORT fields.
615 +
616 +The application server should parse the correct value based on FPORT settings.
617 +
618 +
629 629  === 2.4.1 Device Payload, FPORT~=5 ===
630 630  
631 631  
... ... @@ -633,52 +633,52 @@
633 633  
634 634  Users can also use the downlink command(0x26 01) to ask SDI-12-LB to resend this uplink.
635 635  
636 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
637 -|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0" %)**Device Status (FPORT=5)**
638 -|(% style="background-color:#f2f2f2; width:103px" %)**Size (bytes)**|(% style="background-color:#f2f2f2; width:72px" %)**1**|(% style="background-color:#f2f2f2" %)**2**|(% style="background-color:#f2f2f2; width:91px" %)**1**|(% style="background-color:#f2f2f2; width:86px" %)**1**|(% style="background-color:#f2f2f2; width:44px" %)**2**
639 -|(% style="background-color:#f2f2f2; width:103px" %)**Value**|(% style="background-color:#f2f2f2; width:72px" %)Sensor Model|(% style="background-color:#f2f2f2" %)Firmware Version|(% style="background-color:#f2f2f2; width:91px" %)Frequency Band|(% style="background-color:#f2f2f2; width:86px" %)Sub-band|(% style="background-color:#f2f2f2; width:44px" %)BAT
626 +(% border="1" cellspacing="4" style="background-color:#f7faff; width:437px" %)
627 +|(% colspan="6" style="width:434px" %)**Device Status (FPORT=5)**
628 +|(% style="width:102px" %)**Size (bytes)**|(% style="width:67px" %)**1**|(% style="width:80px" %)**2**|(% style="width:89px" %)**1**|(% style="width:52px" %)**1**|(% style="width:44px" %)**2**
629 +|(% style="width:102px" %)**Value**|(% style="width:67px" %)Sensor Model|(% style="width:80px" %)Firmware Version|(% style="width:89px" %)Frequency Band|(% style="width:52px" %)Sub-band|(% style="width:44px" %)BAT
640 640  
641 641  Example parse in TTNv3
642 642  
643 -[[image:1675215946738-635.png||_mstalt="297778"]]
633 +[[image:1675215946738-635.png]]
644 644  
645 645  
646 -(% style="color:#037691" %)**Sensor Model**(%%): For SDI-12-LB, this value is 0x17
636 +**(% style="color:#037691" %)Sensor Model**(%%): For SDI-12-LB, this value is 0x17
647 647  
648 -(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
638 +**(% style="color:#037691" %)Firmware Version**(%%): 0x0100, Means: v1.0.0 version
649 649  
650 -(% style="color:#037691" %)**Frequency Band**:
640 +**(% style="color:#037691" %)Frequency Band**:
651 651  
652 -0x01: EU868
642 +*0x01: EU868
653 653  
654 -0x02: US915
644 +*0x02: US915
655 655  
656 -0x03: IN865
646 +*0x03: IN865
657 657  
658 -0x04: AU915
648 +*0x04: AU915
659 659  
660 -0x05: KZ865
650 +*0x05: KZ865
661 661  
662 -0x06: RU864
652 +*0x06: RU864
663 663  
664 -0x07: AS923
654 +*0x07: AS923
665 665  
666 -0x08: AS923-1
656 +*0x08: AS923-1
667 667  
668 -0x09: AS923-2
658 +*0x09: AS923-2
669 669  
670 -0x0a: AS923-3
660 +*0x0a: AS923-3
671 671  
672 -0x0b: CN470
662 +*0x0b: CN470
673 673  
674 -0x0c: EU433
664 +*0x0c: EU433
675 675  
676 -0x0d: KR920
666 +*0x0d: KR920
677 677  
678 -0x0e: MA869
668 +*0x0e: MA869
679 679  
680 680  
681 -(% style="color:#037691" %)**Sub-Band**:
671 +**(% style="color:#037691" %)Sub-Band**:
682 682  
683 683  AU915 and US915:value 0x00 ~~ 0x08
684 684  
... ... @@ -687,7 +687,7 @@
687 687  Other Bands: Always 0x00
688 688  
689 689  
690 -(% style="color:#037691" %)**Battery Info**:
680 +**(% style="color:#037691" %)Battery Info**:
691 691  
692 692  Check the battery voltage.
693 693  
... ... @@ -705,20 +705,20 @@
705 705  
706 706  * Periodically Uplink: FPORT=2
707 707  
708 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %)
709 -|=(% style="width: 90px;background-color:#D9E2F3;color:#0070C0" %)(((
698 +(% border="1" cellspacing="4" style="background-color:#f7faff; width:510px" %)
699 +|(% style="width:93px" %)(((
710 710  **Size(bytes)**
711 -)))|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 90px;background-color:#D9E2F3;color:#0070C0" %)**1**|=(% style="width: 240px;background-color:#D9E2F3;color:#0070C0" %)**Length depends on the return from the commands**
701 +)))|(% style="width:83px" %)**2**|(% style="width:70px" %)**1**|(% style="width:234px" %)**Length depends on the return from the commands**
712 712  |(% style="width:93px" %)**Value**|(% style="width:83px" %)(((
713 713  Battery(mV)
714 714  &
715 715  Interrupt_Flag
716 -)))|(% style="width:91px" %)[[PAYLOAD_VER>>||anchor="H3.6Setthepayloadversion"]]|(% style="width:212px" %)(((
706 +)))|(% style="width:70px" %)[[PAYLOAD_VER>>||anchor="H3.6Setthepayloadversion"]]|(% style="width:234px" %)(((
717 717  If the valid payload is too long and exceed the maximum support.
718 718  Payload length in server,server will show payload not provided in the LoRaWAN server.
719 719  )))
720 720  
721 -[[image:1675216282284-923.png||_mstalt="295633"]]
711 +[[image:1675216282284-923.png]]
722 722  
723 723  
724 724  === 2.4.3 Battery Info ===
... ... @@ -734,7 +734,7 @@
734 734  === 2.4.4 Interrupt Pin ===
735 735  
736 736  
737 -This data field shows if this packet is generated by (% style="color:#037691" %)**Interrupt Pin**(%%) or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up. Note: The Internet Pin is a separate pin in the screw terminal. See [[pin mapping>>||anchor="H1.7PinMapping"]].
727 +This data field shows if this packet is generated by **(% style="color:#037691" %)Interrupt Pin**(%%) or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up. Note: The Internet Pin is a separate pin in the screw terminal. See [[pin mapping>>||anchor="H1.7PinMapping"]].
738 738  
739 739  **Example:**
740 740  
... ... @@ -746,15 +746,13 @@
746 746  === 2.4.5 Payload version ===
747 747  
748 748  
749 -The version number of the payload, mainly used for decoding. The default is 01.
750 750  
751 -
752 752  === 2.4.6 ​Decode payload in The Things Network ===
753 753  
754 754  
755 755  While using TTN network, you can add the payload format to decode the payload.
756 756  
757 -[[image:1675216779406-595.png||_mstalt="298376"]]
745 +[[image:1675216779406-595.png]]
758 758  
759 759  
760 760  There is no fix payload decoder in LoRaWAN server because the SDI-12 sensors returns are different. User need to write the decoder themselves for their case.
... ... @@ -767,286 +767,26 @@
767 767  
768 768  The SDI-12-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link:
769 769  
770 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]
758 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]
771 771  
772 772  
773 -== 2.6 Examples To Set SDI commands ==
774 774  
775 -=== 2.6.1 Examples 1 ~-~- General Example ===
776 776  
763 +== 2.6 Frequency Plans ==
777 777  
778 -COM port and SDI-12 sensor communication converted to SDI-12-LB and SDI-12 sensor communication.
779 779  
780 -[[image:image-20230222143809-1.png||_mstalt="429962" height="564" width="729"]]
781 -
782 -
783 -(% style="color:blue" %)**1) The AT+COMMANDx command is applied to the red arrow part, and sends the SDI12 command to the SDI12 sensor:**
784 -
785 -a. Send the first command and get the first reply:
786 -
787 -(% style="color:#037691" %)**AT+COMMANDx=1I!,0,0,1**
788 -
789 -b. Send the second command and get the second reply:
790 -
791 -(% style="color:#037691" %)**AT+COMMANDx=2I!,0,0,1**
792 -
793 -c. Send the third command and get the third reply:
794 -
795 -(% style="color:#037691" %)**AT+COMMANDx=3I!,0,0,1**
796 -
797 -d. Send the fourth command and get the fourth reply:
798 -
799 -(% style="color:#037691" %)**AT+COMMANDx=4I!,0,0,1**
800 -
801 -e. Send the fifth command plus the sixth command, get the sixth reply:
802 -
803 -(% style="color:#037691" %)**AT+COMMANDx=1M!,2,1,1**
804 -
805 -f. Send the seventh command plus the eighth command, get the eighth reply:
806 -
807 -(% style="color:#037691" %)**AT+COMMANDx=2M!,2,1,1**
808 -
809 -g. Send the ninth command plus the tenth command, get the tenth reply:
810 -
811 -(% style="color:#037691" %)**AT+COMMANDx=3M!,1,1,1**
812 -
813 -h. Send the eleventh command plus the twelfth command, get the twelfth reply:
814 -
815 -(% style="color:#037691" %)**AT+COMMANDx=4M!,1,1,1**
816 -
817 -
818 -(% style="color:blue" %)**2) The AT+DATACUTx command is applied to the green arrow part, receiving and cut out data from the SDI12 sensor:**
819 -
820 -a. The first reply, all 34 characters: ”113TRUEBNERSMT100038220303182331<CR><LF>”
821 -
822 -Cut out all characters: (% _mstmutation="1" style="color:#037691" %)**AT+ALLDATAMOD=1 or AT+DATACUTx=34,2,1~~34**(% style="color:#037691" %);
823 -
824 -b. The sixth reply, all 31 characters:”1+19210+1.04+0.00+22.49+11.75<CR><LF>”
825 -
826 -Cut out all characters: (% _mstmutation="1" style="color:#037691" %)**AT+ALLDATAMOD=1 or AT+DATACUTx=31,2,1~~31**(% style="color:#037691" %);
827 -
828 -c. The eighth reply, all 31 characters:”2+18990+1.08+0.00+22.24+11.80<CR><LF>”
829 -
830 -Cut out all characters: (% _mstmutation="1" style="color:#037691" %)**AT+ALLDATAMOD=1 or AT+DATACUTx=31,2,1~~31**(% style="color:#037691" %);
831 -
832 -d. The tenth reply, all 15 characters:”3-2919.8+24.0<CR><LF>”
833 -
834 -Cut out all characters: (% _mstmutation="1" style="color:#037691" %)**AT+ALLDATAMOD=1 or AT+DATACUTx=15,2,1~~15**(% style="color:#037691" %);
835 -
836 -e. The twelfth reply, all 25 characters:”4+30.8+22.84+4.7+954.38<CR><LF>”
837 -
838 -Partial cut, the cut sensor address and the first two parameters:(% style="color:#037691" %)**AT+DATACUTx=25,2,1~~12, cut out the character field ” 4+30.8+22.84”**.
839 -
840 -
841 -=== 2.6.2 Example 2 ~-~- Connect to Hygrovue10 ===
842 -
843 -==== 2.6.2.1 Reference Manual and Command ====
844 -
845 -
846 -* [[Hygrovue10 Product Page>>https://www.campbellsci.com/hygrovue10]]
847 -
848 -* Commands to be used in PC and output.
849 -
850 -~1. check device address
851 -
852 -2. change device address
853 -
854 -3. check device ID
855 -
856 -4. start measure
857 -
858 -5. Get Meausre result
859 -
860 -[[image:image-20230603120209-2.png||height="281" width="267"]]
861 -
862 -
863 -==== 2.6.2.2 Hardware Connection to SDI-12-LB ====
864 -
865 -
866 -[[image:image-20230603120515-3.png]]
867 -
868 -
869 -==== 2.6.2.3 Commands set in SDI-12-LB and uplink payload ====
870 -
871 -
872 -[[image:image-20230603120648-4.png]]
873 -
874 -[[image:image-20230603120726-5.png]]
875 -
876 -
877 -**Data in TTN:**
878 -
879 -[[image:image-20230603120859-6.png||height="118" width="1285"]]
880 -
881 -
882 -=== (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.3 Example 3 ~-~- Connect to SIL-400 ===
883 -
884 -==== 2.6.3.1 Reference Manual and Command ====
885 -
886 -
887 -* [[SIL-400 Product Page>>https://www.apogeeinstruments.com/sil-411-commercial-grade-sdi-12-digital-output-standard-field-of-view-infrared-radiometer-sensor/]]
888 -
889 -* Commands to be used in PC and output.
890 -
891 -~1. check device address
892 -
893 -2. change device address
894 -
895 -3. check device ID
896 -
897 -4. start measure
898 -
899 -5. Get Meausre result
900 -
901 -[[image:image-20230603121606-7.png||height="242" width="307"]]
902 -
903 -
904 -==== 2.6.3.2 Hardware Connection to SDI-12-LB ====
905 -
906 -
907 -[[image:image-20230603121643-8.png||height="442" width="656"]]
908 -
909 -
910 -==== 2.6.3.3 Commands set in SDI-12-LB and uplink payload ====
911 -
912 -
913 -[[image:image-20230603121721-9.png]]
914 -
915 -[[image:image-20230628090323-1.png||height="414" width="694"]]
916 -
917 -Data in TTN:
918 -
919 -[[image:image-20230603121826-11.png||height="155" width="1104"]]
920 -
921 -
922 -
923 -=== (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.4 Example 4 ~-~- Connect to TEROS-12 ===
924 -
925 -==== 2.6.4.1 Reference Manual and Command ====
926 -
927 -
928 -* [[TEROS-12 Product Page>>https://www.metergroup.com/en/meter-environment/products/teros-12-soil-moisture-sensor]]
929 -
930 -* Commands to be used in PC and output.
931 -
932 -1.check device address
933 -
934 -2.change device address
935 -
936 -3.check device ID
937 -
938 -4.start measure
939 -
940 -5.Get Meausre result
941 -
942 -[[image:image-20230603122248-16.png||height="196" width="198"]]
943 -
944 -
945 -==== 2.6.4.2 Hardware Connection to SDI-12-LB ====
946 -
947 -
948 -[[image:image-20230603122212-15.png||height="502" width="667"]]
949 -
950 -
951 -==== 2.6.4.3 Commands set in SDI-12-LB and uplink payload ====
952 -
953 -
954 -[[image:image-20230603122040-12.png]]
955 -
956 -[[image:image-20230603122109-13.png||height="469" width="762"]]
957 -
958 -
959 -**Data in TTN:**
960 -
961 -[[image:image-20230603122139-14.png||height="148" width="1128"]]
962 -
963 -
964 -=== (% id="cke_bm_1489640S" style="display:none" %) (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.5 Example 5 ~-~- Connect to SIL-400/TEROS-12 & Hygrovue10 ===
965 -
966 -==== 2.6.5.1 Important Notice! ====
967 -
968 -
969 -* The product page and reference command see above example 2,3,4
970 -
971 -* All of these SDI-12 sensors use the same address (address 0) by default. So we need to change their address to different address, by using **aAb!** command. See above example.
972 -
973 -* The sensor needs to be powered to a steady statue. So the 12VT time need to be set to the maximum stable time for the sensors. in this example, it is 13 seconds.
974 -
975 -* If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB.
976 -
977 -==== 2.6.5.2 Hardware Connection to SDI-12-LB ====
978 -
979 -
980 -[[image:image-20230603122508-17.png||height="526" width="742"]]
981 -
982 -
983 -==== 2.6.5.3 Commands set in SDI-12-LB and uplink payload ====
984 -
985 -
986 -[[image:image-20230603122549-18.png]]
987 -
988 -[[image:image-20230603122623-19.png||height="483" width="1121"]]
989 -
990 -
991 -**Data in TTN:**
992 -
993 -[[image:image-20230603122719-20.png||height="151" width="1179"]]
994 -
995 -
996 -=== (% id="cke_bm_4783S" style="display:none" %) (%%)2.6.6 Example 6 ~-~- Connect to ENTELECHY-EP_SDI-12 ===
997 -
998 -==== 2.6.4.1 Reference Manual and Command ====
999 -
1000 -
1001 -* [[https:~~/~~/enviroprosoilprobes.com/wp-content/uploads/2019/11/ENTELECHY-EP_SDI-12-Commands.pdf>>url:https://enviroprosoilprobes.com/wp-content/uploads/2019/11/ENTELECHY-EP_SDI-12-Commands.pdf]]
1002 -
1003 -* Commands to be used in PC and output.
1004 -
1005 -1.check device address
1006 -
1007 -2.change device address
1008 -
1009 -3.check device ID
1010 -
1011 -4.start measure
1012 -
1013 -5.Get Meausre result
1014 -
1015 -
1016 -[[image:image-20230627174559-3.png]]
1017 -
1018 -==== 2.6.4.2 Hardware Connection to SDI-12-LB ====
1019 -
1020 -[[image:image-20230627174446-2.png]]
1021 -
1022 -
1023 -
1024 -==== 2.6.4.3 Commands set in SDI-12-LB and uplink payload ====
1025 -
1026 -
1027 -[[image:image-20230627175513-4.png||height="596" width="576"]]
1028 -
1029 -[[image:image-20230627175736-5.png||height="429" width="693"]]
1030 -
1031 -
1032 -**Data in TTN:**
1033 -
1034 -[[image:image-20230627180303-6.png||height="292" width="1171"]]
1035 -
1036 -== 2.7 Frequency Plans ==
1037 -
1038 -
1039 1039  The SDI-12-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
1040 1040  
1041 1041  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
1042 1042  
1043 1043  
1044 -== 2.8 Firmware Change Log ==
1045 1045  
772 +== 2.7 Firmware Change Log ==
1046 1046  
774 +
1047 1047  **Firmware download link:**
1048 1048  
1049 -[[https:~~/~~/www.dropbox.com/sh/qrbgbikb109lkiv/AACBR-v_ZhZAMengcY7Nsa1ja?dl=0>>https://www.dropbox.com/sh/qrbgbikb109lkiv/AACBR-v_ZhZAMengcY7Nsa1ja?dl=0]]
777 +[[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]]
1050 1050  
1051 1051  
1052 1052  = 3. Configure SDI-12-LB via AT Command or LoRaWAN Downlink =
... ... @@ -1054,12 +1054,12 @@
1054 1054  
1055 1055  Use can configure SDI-12-LB via AT Command or LoRaWAN Downlink.
1056 1056  
1057 -* AT Command Connection: See [[FAQ>>||anchor="H7.FAQ"]].
785 +* AT Command Connection: See [[FAQ>>path:#AT_COMMAND]].
1058 1058  * LoRaWAN Downlink instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
1059 1059  
1060 1060  There are two kinds of commands to configure SDI-12-LB, they are:
1061 1061  
1062 -* (% style="color:blue" %)**General Commands**.
790 +* **General Commands**.
1063 1063  
1064 1064  These commands are to configure:
1065 1065  
... ... @@ -1068,15 +1068,15 @@
1068 1068  
1069 1069  They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:
1070 1070  
1071 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
799 +[[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_Downlink_Command>>url:http://wiki.dragino.com/index.php?title=End_Device_Downlink_Command]]
1072 1072  
1073 1073  
1074 -* (% style="color:blue" %)**Commands special design for SDI-12-LB**
802 +* **Commands special design for SDI-12-LB**
1075 1075  
1076 1076  These commands only valid for SDI-12-LB, as below:
1077 1077  
1078 1078  
1079 -== 3.1 Set Transmit Interval Time ==
807 +== ​​​​​​​3.1 Set Transmit Interval Time ==
1080 1080  
1081 1081  
1082 1082  Feature: Change LoRaWAN End Node Transmit Interval.
... ... @@ -1083,14 +1083,14 @@
1083 1083  
1084 1084  (% style="color:blue" %)**AT Command: AT+TDC**
1085 1085  
1086 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
1087 -|=(% style="width: 160px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Command Example**|=(% style="width: 160px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Function**|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1088 -|(% style="background-color:#f2f2f2; width:157px" %)AT+TDC=?|(% style="background-color:#f2f2f2; width:166px" %)Show current transmit Interval|(% style="background-color:#f2f2f2" %)(((
814 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
815 +|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 137px;" %)**Function**|=**Response**
816 +|(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|(((
1089 1089  30000
1090 1090  OK
1091 1091  the interval is 30000ms = 30s
1092 1092  )))
1093 -|(% style="background-color:#f2f2f2; width:157px" %)AT+TDC=60000|(% style="background-color:#f2f2f2; width:166px" %)Set Transmit Interval|(% style="background-color:#f2f2f2" %)(((
821 +|(% style="width:156px" %)AT+TDC=60000|(% style="width:137px" %)Set Transmit Interval|(((
1094 1094  OK
1095 1095  Set transmit interval to 60000ms = 60 seconds
1096 1096  )))
... ... @@ -1112,20 +1112,20 @@
1112 1112  
1113 1113  (% style="color:blue" %)**AT Command: AT+INTMOD**
1114 1114  
1115 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
1116 -|=(% style="width: 154px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1117 -|(% style="background-color:#f2f2f2; width:154px" %)AT+INTMOD=?|(% style="background-color:#f2f2f2; width:196px" %)Show current interrupt mode|(% style="background-color:#f2f2f2; width:157px" %)(((
843 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
844 +|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 187px;" %)**Function**|=(% style="width: 165px;" %)**Response**
845 +|(% style="width:156px" %)AT+INTMOD=?|(% style="width:187px" %)Show current interrupt mode|(% style="width:165px" %)(((
1118 1118  0
1119 1119  OK
1120 -the mode is 0 =Disable Interrupt
848 +the mode is 0 = No interruption
1121 1121  )))
1122 -|(% style="background-color:#f2f2f2; width:154px" %)AT+INTMOD=2|(% style="background-color:#f2f2f2; width:196px" %)(((
850 +|(% style="width:156px" %)AT+INTMOD=2|(% style="width:187px" %)(((
1123 1123  Set Transmit Interval
1124 -0. (Disable Interrupt),
1125 -~1. (Trigger by rising and falling edge)
1126 -2. (Trigger by falling edge)
1127 -3. (Trigger by rising edge)
1128 -)))|(% style="background-color:#f2f2f2; width:157px" %)OK
852 +~1. (Disable Interrupt),
853 +2. (Trigger by rising and falling edge)
854 +3. (Trigger by falling edge)
855 +4. (Trigger by rising edge)
856 +)))|(% style="width:165px" %)OK
1129 1129  
1130 1130  (% style="color:blue" %)**Downlink Command: 0x06**
1131 1131  
... ... @@ -1143,54 +1143,52 @@
1143 1143  
1144 1144  (% style="color:blue" %)**AT Command: AT+3V3T**
1145 1145  
1146 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:474px" %)
1147 -|=(% style="width: 154px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 201px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 116px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1148 -|(% style="background-color:#f2f2f2; width:154px" %)AT+3V3T=?|(% style="background-color:#f2f2f2; width:201px" %)Show 3V3 open time.|(% style="background-color:#f2f2f2; width:116px" %)(((
874 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:474px" %)
875 +|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 201px;" %)**Function**|=(% style="width: 116px;" %)**Response**
876 +|(% style="width:154px" %)AT+3V3T=?|(% style="width:201px" %)Show 3V3 open time.|(% style="width:116px" %)(((
1149 1149  0
1150 1150  OK
1151 1151  )))
1152 -|(% style="background-color:#f2f2f2; width:154px" %)AT+3V3T=0|(% style="background-color:#f2f2f2; width:201px" %)Normally open 3V3 power supply.|(% style="background-color:#f2f2f2; width:116px" %)(((
880 +|(% style="width:154px" %)AT+3V3T=0|(% style="width:201px" %)Normally open 3V3 power supply.|(% style="width:116px" %)(((
1153 1153  OK
1154 1154  default setting
1155 1155  )))
1156 -|(% style="background-color:#f2f2f2; width:154px" %)AT+3V3T=1000|(% style="background-color:#f2f2f2; width:201px" %)Close after a delay of 1000 milliseconds.|(% style="background-color:#f2f2f2; width:116px" %)(((
884 +|(% style="width:154px" %)AT+3V3T=1000|(% style="width:201px" %)Close after a delay of 1000 milliseconds.|(% style="width:116px" %)(((
1157 1157  OK
1158 1158  )))
1159 -|(% style="background-color:#f2f2f2; width:154px" %)AT+3V3T=65535|(% style="background-color:#f2f2f2; width:201px" %)Normally closed 3V3 power supply.|(% style="background-color:#f2f2f2; width:116px" %)(((
887 +|(% style="width:154px" %)AT+3V3T=65535|(% style="width:201px" %)Normally closed 3V3 power supply.|(% style="width:116px" %)(((
1160 1160  OK
1161 1161  )))
1162 1162  
1163 1163  (% style="color:blue" %)**AT Command: AT+5VT**
1164 1164  
1165 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:470px" %)
1166 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 114px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1167 -|(% style="background-color:#f2f2f2; width:155px" %)AT+5VT=?|(% style="background-color:#f2f2f2; width:196px" %)Show 5V open time.|(% style="background-color:#f2f2f2; width:114px" %)(((
893 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:470px" %)
894 +|=(% style="width: 155px;" %)**Command Example**|=(% style="width: 196px;" %)**Function**|=(% style="width: 114px;" %)**Response**
895 +|(% style="width:155px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:114px" %)(((
1168 1168  0
1169 1169  OK
1170 1170  )))
1171 -|(% style="background-color:#f2f2f2; width:155px" %)AT+5VT=0|(% style="background-color:#f2f2f2; width:196px" %)Normally closed 5V power supply.|(% style="background-color:#f2f2f2; width:114px" %)(((
899 +|(% style="width:155px" %)AT+5VT=0|(% style="width:196px" %)Normally closed 5V power supply.|(% style="width:114px" %)(((
1172 1172  OK
1173 1173  default setting
1174 1174  )))
1175 -|(% style="background-color:#f2f2f2; width:155px" %)AT+5VT=1000|(% style="background-color:#f2f2f2; width:196px" %)Close after a delay of 1000 milliseconds.|(% style="background-color:#f2f2f2; width:114px" %)(((
903 +|(% style="width:155px" %)AT+5VT=1000|(% style="width:196px" %)Close after a delay of 1000 milliseconds.|(% style="width:114px" %)(((
1176 1176  OK
1177 1177  )))
1178 -|(% style="background-color:#f2f2f2; width:155px" %)AT+5VT=65535|(% style="background-color:#f2f2f2; width:196px" %)Normally open 5V power supply.|(% style="background-color:#f2f2f2; width:114px" %)(((
906 +|(% style="width:155px" %)AT+5VT=65535|(% style="width:196px" %)Normally open 5V power supply.|(% style="width:114px" %)(((
1179 1179  OK
1180 1180  )))
1181 1181  
1182 -(% style="color:blue" %)**AT Command: AT+12VT **
910 +(% style="color:blue" %)**AT Command: AT+12VT**
1183 1183  
1184 -(% style="color:blue" %)**(The v1.2 version is enabled for 1 second by default, and the version below v1.2 is disabled by default)**
1185 -
1186 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:443px" %)
1187 -|=(% style="width: 156px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 199px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 83px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1188 -|(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=?|(% style="background-color:#f2f2f2; width:199px" %)Show 12V open time.|(% style="background-color:#f2f2f2; width:83px" %)(((
912 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:443px" %)
913 +|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 199px;" %)**Function**|=(% style="width: 83px;" %)**Response**
914 +|(% style="width:156px" %)AT+12VT=?|(% style="width:199px" %)Show 12V open time.|(% style="width:83px" %)(((
1189 1189  0
1190 1190  OK
1191 1191  )))
1192 -|(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=0|(% style="background-color:#f2f2f2; width:199px" %)Normally closed 12V power supply.|(% style="background-color:#f2f2f2; width:83px" %)OK
1193 -|(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=500|(% style="background-color:#f2f2f2; width:199px" %)Close after a delay of 500 milliseconds.|(% style="background-color:#f2f2f2; width:83px" %)(((
918 +|(% style="width:156px" %)AT+12VT=0|(% style="width:199px" %)Normally closed 12V power supply.|(% style="width:83px" %)OK
919 +|(% style="width:156px" %)AT+12VT=500|(% style="width:199px" %)Close after a delay of 500 milliseconds.|(% style="width:83px" %)(((
1194 1194  OK
1195 1195  )))
1196 1196  
... ... @@ -1214,13 +1214,13 @@
1214 1214  
1215 1215  (% style="color:blue" %)**AT Command: AT+ALLDATAMOD**
1216 1216  
1217 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:437px" %)
1218 -|=(% style="background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**Response**
1219 -|(% style="background-color:#f2f2f2" %)AT+ALLDATAMOD=?|(% style="background-color:#f2f2f2" %)Show current all data mode|(% style="background-color:#f2f2f2" %)(((
943 +(% border="1" cellspacing="4" style="background-color:#f7faff; width:437px" %)
944 +|=**Command Example**|=**Function**|=**Response**
945 +|AT+ALLDATAMOD=?|Show current all data mode|(((
1220 1220  0
1221 1221  OK
1222 1222  )))
1223 -|(% style="background-color:#f2f2f2" %)AT+ALLDATAMOD=1|(% style="background-color:#f2f2f2" %)Set all data mode is 1.|(% style="background-color:#f2f2f2" %)OK
949 +|AT+ALLDATAMOD=1|Set all data mode is 1.|OK
1224 1224  
1225 1225  (% style="color:blue" %)**Downlink Command: 0xAB**
1226 1226  
... ... @@ -1236,21 +1236,21 @@
1236 1236  
1237 1237  (% style="color:blue" %)**AT Command: AT+DATAUP**
1238 1238  
1239 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
1240 -|=(% style="width: 154px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 266px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**Response**
1241 -|(% style="background-color:#f2f2f2; width:154px" %)AT+DATAUP =?|(% style="background-color:#f2f2f2; width:266px" %)Show current splicing payload for uplink mode|(% style="background-color:#f2f2f2" %)(((
965 +(% border="1" cellspacing="4" style="background-color:#f7faff; width:510px" %)
966 +|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 266px;" %)**Function**|=**Response**
967 +|(% style="width:154px" %)AT+DATAUP =?|(% style="width:266px" %)Show current splicing payload for uplink mode|(((
1242 1242  0
1243 1243  OK
1244 1244  )))
1245 -|(% style="background-color:#f2f2f2; width:154px" %)AT+DATAUP =0|(% style="background-color:#f2f2f2; width:266px" %)(((
971 +|(% style="width:154px" %)AT+DATAUP =0|(% style="width:266px" %)(((
1246 1246  Set splicing payload for uplink mode is 0.
1247 -)))|(% style="background-color:#f2f2f2" %)(((
973 +)))|(((
1248 1248  OK
1249 1249  )))
1250 -|(% style="background-color:#f2f2f2; width:154px" %)AT+DATAUP =1|(% style="background-color:#f2f2f2; width:266px" %)Set splicing payload for uplink mode is 1 , and the each splice uplink is sent sequentially.|(% style="background-color:#f2f2f2" %)OK
1251 -|(% style="background-color:#f2f2f2; width:154px" %)AT+DATAUP =1,20000|(% style="background-color:#f2f2f2; width:266px" %)(((
976 +|(% style="width:154px" %)AT+DATAUP =1|(% style="width:266px" %)Set splicing payload for uplink mode is 1 , and the each splice uplink is sent sequentially.|OK
977 +|(% style="width:154px" %)AT+DATAUP =1,20000|(% style="width:266px" %)(((
1252 1252  Set splicing payload for uplink mode is 1, and the uplink interval of each splice to 20000 milliseconds.
1253 -)))|(% style="background-color:#f2f2f2" %)OK
979 +)))|OK
1254 1254  
1255 1255  (% style="color:blue" %)**Downlink Command: 0xAD**
1256 1256  
... ... @@ -1265,18 +1265,17 @@
1265 1265  
1266 1266  == 3.6 Set the payload version ==
1267 1267  
1268 -
1269 1269  Feature, Set the payload version.
1270 1270  
1271 1271  (% style="color:blue" %)**AT Command: AT+PAYVER**
1272 1272  
1273 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:437px" %)
1274 -|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 192px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**Response**
1275 -|(% style="background-color:#f2f2f2; width:158px" %)AT+PAYVER=?|(% style="background-color:#f2f2f2; width:192px" %)Show current payload version|(% style="background-color:#f2f2f2" %)(((
998 +(% border="1" cellspacing="4" style="background-color:#f7faff; width:437px" %)
999 +|=(% style="width: 158px;" %)**Command Example**|=(% style="width: 192px;" %)**Function**|=**Response**
1000 +|(% style="width:158px" %)AT+PAYVER=?|(% style="width:192px" %)Show current payload version|(((
1276 1276  1
1277 1277  OK
1278 1278  )))
1279 -|(% style="background-color:#f2f2f2; width:158px" %)AT+PAYVER=5|(% style="background-color:#f2f2f2; width:192px" %)Set payload version is 5.|(% style="background-color:#f2f2f2" %)OK
1004 +|(% style="width:158px" %)AT+PAYVER=5|(% style="width:192px" %)Set payload version is 5.|OK
1280 1280  
1281 1281  (% style="color:blue" %)**Downlink Command: 0xAE**
1282 1282  
... ... @@ -1285,86 +1285,126 @@
1285 1285  * Example 1: Downlink Payload: AE 01  ~/~/  AT+PAYVER=1
1286 1286  * Example 2: Downlink Payload: AE 05  ~/~/  AT+PAYVER=5
1287 1287  
1288 -= 4. Battery & Power Consumption =
1013 += 4. Battery & how to replace =
1289 1289  
1015 +== 4.1 Battery Type ==
1290 1290  
1291 -SDI-12-LB uses ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
1292 1292  
1293 -[[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
1018 +SDI-12-LB is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>https://www.dropbox.com/sh/w9l2oa3ytpculph/AAAPtt-apH4lYfCj-2Y6lHvQa?dl=0]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
1294 1294  
1295 1295  
1296 -= 5. Remote Configure device =
1021 +The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
1297 1297  
1298 -== 5.1 Connect via BLE ==
1023 +[[image:1675146710956-626.png]]
1299 1299  
1300 1300  
1301 -Please see this instruction for how to configure via BLE: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]
1026 +Minimum Working Voltage for the SDI-12-LB:
1302 1302  
1028 +SDI-12-LB:  2.45v ~~ 3.6v
1303 1303  
1304 -== 5.2 AT Command Set ==
1305 1305  
1031 +== 4.2 Replace Battery ==
1306 1306  
1307 1307  
1308 -= 6. OTA firmware update =
1034 +Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
1309 1309  
1036 +And make sure the positive and negative pins match.
1310 1310  
1311 -Please see this link for how to do OTA firmware update.
1312 1312  
1313 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
1039 +== 4.3 Power Consumption Analyze ==
1314 1314  
1315 1315  
1316 -= 7. FAQ =
1042 +Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
1317 1317  
1318 -== 7.1 How to use AT Command  via UART to access device? ==
1044 +Instruction to use as below:
1319 1319  
1046 +(% style="color:blue" %)**Step 1:**(%%) Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0>>https://www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0]]
1320 1320  
1321 -See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]
1048 +(% style="color:blue" %)**Step 2:**(%%) Open it and choose
1322 1322  
1050 +* Product Model
1051 +* Uplink Interval
1052 +* Working Mode
1323 1323  
1324 -== 7.2 How to update firmware via UART port? ==
1054 +And the Life expectation in difference case will be shown on the right.
1325 1325  
1056 +[[image:1675146895108-304.png]]
1326 1326  
1327 -See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]
1328 1328  
1059 +The battery related documents as below:
1329 1329  
1330 -== 7.3 How to change the LoRa Frequency Bands/Region? ==
1061 +* [[Battery Dimension>>https://www.dropbox.com/s/ox5g9njwjle7aw3/LSN50-Battery-Dimension.pdf?dl=0]],
1062 +* [[Lithium-Thionyl Chloride Battery datasheet, Tech Spec>>https://www.dropbox.com/sh/d4oyfnp8o94180o/AABQewCNSh5GPeQH86UxRgQQa?dl=0]]
1063 +* [[Lithium-ion Battery-Capacitor datasheet>>https://www.dropbox.com/s/791gjes2lcbfi1p/SPC_1520_datasheet.jpg?dl=0]], [[Tech Spec>>https://www.dropbox.com/s/4pkepr9qqqvtzf2/SPC1520%20Technical%20Specification20171123.pdf?dl=0]]
1331 1331  
1065 +[[image:image-20230131145708-3.png]]
1332 1332  
1333 -You can follow the instructions for [[how to upgrade image>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]].
1334 -When downloading the images, choose the required image file for download. ​
1335 1335  
1068 +=== 4.3.1 ​Battery Note ===
1336 1336  
1337 -= 8. ​Order Info =
1338 1338  
1071 +The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
1339 1339  
1340 -(((
1341 -(% style="color:blue" %)**Part Number: SDI-12-LB-XXX**
1342 -)))
1343 1343  
1344 -(((
1345 -(% style="color:blue" %)**XXX**(%%): The default frequency band
1346 -)))
1074 +=== 4.3.2 Replace the battery ===
1347 1347  
1348 -(((
1349 -(% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band
1350 -(% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band
1351 -(% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band
1352 -(% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band
1353 -(% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band
1354 -(% style="color:red" %)**US915**(%%): LoRaWAN US915 band
1355 -(% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band
1356 -(% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1357 -)))
1358 1358  
1077 +You can change the battery in the SDI-12-LB.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
1359 1359  
1360 -= 9. Packing Info =
1079 +The default battery pack of SDI-12-LB includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1361 1361  
1362 1362  
1363 -(% style="color:#037691" %)**Package Includes**:
1364 1364  
1083 += 5. Remote Configure device =
1084 +
1085 +== 5.1 Connect via BLE ==
1086 +
1087 +
1088 +Please see this instruction for how to configure via BLE: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]
1089 +
1090 +
1091 +== 5.2 AT Command Set ==
1092 +
1093 +
1094 +
1095 += 6. OTA firmware update =
1096 +
1097 +
1098 +Please see this link for how to do OTA firmware update.
1099 +
1100 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
1101 +
1102 +
1103 +
1104 += 7. ​Order Info =
1105 +
1106 +
1107 +Part Number: SDI-12-LB-XXX
1108 +XXX: The default frequency band
1109 +
1110 +AS923: LoRaWAN AS923 band
1111 +AU915: LoRaWAN AU915 band
1112 +EU433: LoRaWAN EU433 band
1113 +EU868: LoRaWAN EU868 band
1114 +KR920: LoRaWAN KR920 band
1115 +US915: LoRaWAN US915 band
1116 +IN865: LoRaWAN IN865 band
1117 +CN470: LoRaWAN CN470 band
1118 +
1119 +
1120 +
1121 +
1122 +
1123 +
1124 +
1125 += 8. Packing Info =
1126 +
1127 +
1128 +**Package Includes**:
1129 +
1365 1365  * SDI-12-LB SDI-12 to LoRaWAN Converter x 1
1366 1366  
1367 -(% style="color:#037691" %)**Dimension and weight**:
1132 +**Dimension and weight**:
1368 1368  
1369 1369  * Device Size: cm
1370 1370  * Device Weight: g
... ... @@ -1371,9 +1371,11 @@
1371 1371  * Package Size / pcs : cm
1372 1372  * Weight / pcs : g
1373 1373  
1374 -= 10. ​Support =
1139 += 9. ​Support =
1375 1375  
1376 1376  
1377 1377  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1378 1378  
1379 1379  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
1145 +
1146 +
image-20230201145019-19.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -82.2 KB
Content
image-20230201152430-20.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -16.5 KB
Content
image-20230222143809-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bei
Size
... ... @@ -1,1 +1,0 @@
1 -322.1 KB
Content
image-20230426084456-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -190.0 KB
Content
image-20230603120127-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -5.7 KB
Content
image-20230603120209-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -22.8 KB
Content
image-20230603120515-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -489.3 KB
Content
image-20230603120648-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -100.8 KB
Content
image-20230603120726-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -133.2 KB
Content
image-20230603120859-6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -55.9 KB
Content
image-20230603121606-7.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -24.4 KB
Content
image-20230603121643-8.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -889.7 KB
Content
image-20230603121721-9.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -105.4 KB
Content
image-20230603121752-10.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -160.0 KB
Content
image-20230603121826-11.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -52.8 KB
Content
image-20230603122040-12.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -128.1 KB
Content
image-20230603122109-13.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -271.1 KB
Content
image-20230603122139-14.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -70.4 KB
Content
image-20230603122212-15.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -818.3 KB
Content
image-20230603122248-16.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -12.7 KB
Content
image-20230603122508-17.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -980.2 KB
Content
image-20230603122549-18.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -90.9 KB
Content
image-20230603122623-19.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -139.5 KB
Content
image-20230603122719-20.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -83.8 KB
Content
image-20230627164957-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bei
Size
... ... @@ -1,1 +1,0 @@
1 -835.0 KB
Content
image-20230627165744-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bei
Size
... ... @@ -1,1 +1,0 @@
1 -4.6 KB
Content
image-20230627174446-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bei
Size
... ... @@ -1,1 +1,0 @@
1 -835.0 KB
Content
image-20230627174559-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bei
Size
... ... @@ -1,1 +1,0 @@
1 -4.6 KB
Content
image-20230627175513-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bei
Size
... ... @@ -1,1 +1,0 @@
1 -12.0 KB
Content
image-20230627175736-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bei
Size
... ... @@ -1,1 +1,0 @@
1 -10.4 KB
Content
image-20230627180303-6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bei
Size
... ... @@ -1,1 +1,0 @@
1 -65.1 KB
Content
image-20230628090323-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -137.2 KB
Content
image-20230628091055-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -24.9 KB
Content
image-20230628091130-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Saxer
Size
... ... @@ -1,1 +1,0 @@
1 -84.0 KB
Content