From version < 85.1 >
edited by Saxer Lin
on 2023/06/28 09:11
To version < 87.7 >
edited by Xiaoling
on 2023/10/23 15:30
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Saxer
1 +XWiki.Xiaoling
Content
... ... @@ -77,8 +77,7 @@
77 77  (% style="color:#037691" %)**Common DC Characteristics:**
78 78  
79 79  * Supply Voltage: 2.5v ~~ 3.6v
80 -* Support current: 5V 300mA
81 - 12V 100mA
80 +* Support current: 5V 300mA, 12V 100mA
82 82  * Operating Temperature: -40 ~~ 85°C
83 83  
84 84  (% style="color:#037691" %)**LoRa Spec:**
... ... @@ -356,7 +356,6 @@
356 356  
357 357  
358 358  
359 -
360 360  ==== (% style="color:blue" %)**aR0!- aR9!,  aRC0!- aRC9!**(%%) ====
361 361  
362 362  
... ... @@ -425,17 +425,25 @@
425 425  [[image:image-20230201092355-17.png||_mstalt="454337" height="426" width="1135"]]
426 426  
427 427  
428 -(% style="color:blue" %)**Example2: **(%%) AT+CFGDEV =0M!,1,1  or  AT+CFGDEV =0C!,1,1
426 +(% style="color:blue" %)**Example2: **(%%) AT+CFGDEV =0M!,1,1
429 429  
430 430  (% style="color:#037691" %)**0M! **(%%): SDI-12 Command,
431 431  
432 432  (% style="color:#037691" %)**1 **(%%): Delay 1 second.  ( 0: 810 mini-second)
433 433  
434 -(% style="color:#037691" %)**1 **(%%):Use aD0! command access.
432 +(% style="color:#037691" %)**1 **(%%): Use aD0! command access.
435 435  
436 436  Equal Downlink: 0xA8 03 30  4D 21 01 01 01
437 437  
438 438  
437 +The following is the display information on the serial port and the server.
438 +
439 +
440 +[[image:image-20230628091055-1.png||height="368" width="462"]]
441 +
442 +[[image:image-20230628091130-2.png||height="258" width="879"]]
443 +
444 +
439 439  === 2.3.3 Convert ASCII to String ===
440 440  
441 441  
... ... @@ -871,7 +871,7 @@
871 871  [[image:image-20230603120859-6.png||height="118" width="1285"]]
872 872  
873 873  
874 -=== (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.3 Example 3 ~-~- Connect to SIL-400 ===
880 +=== 2.6.3 Example 3 ~-~- Connect to SIL-400 ===
875 875  
876 876  ==== 2.6.3.1 Reference Manual and Command ====
877 877  
... ... @@ -912,7 +912,7 @@
912 912  
913 913  
914 914  
915 -=== (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.4 Example 4 ~-~- Connect to TEROS-12 ===
921 +=== 2.6.4 Example 4 ~-~- Connect to TEROS-12 ===
916 916  
917 917  ==== 2.6.4.1 Reference Manual and Command ====
918 918  
... ... @@ -953,7 +953,7 @@
953 953  [[image:image-20230603122139-14.png||height="148" width="1128"]]
954 954  
955 955  
956 -=== (% id="cke_bm_1489640S" style="display:none" %) (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.5 Example 5 ~-~- Connect to SIL-400/TEROS-12 & Hygrovue10 ===
962 +=== 2.6.5 Example 5 ~-~- Connect to SIL-400/TEROS-12 & Hygrovue10 ===
957 957  
958 958  ==== 2.6.5.1 Important Notice! ====
959 959  
... ... @@ -985,9 +985,9 @@
985 985  [[image:image-20230603122719-20.png||height="151" width="1179"]]
986 986  
987 987  
988 -=== (% id="cke_bm_4783S" style="display:none" %) (%%)2.6.6 Example 6 ~-~- Connect to ENTELECHY-EP_SDI-12 ===
994 +=== 2.6.6 Example 6 ~-~- Connect to ENTELECHY-EP_SDI-12 ===
989 989  
990 -==== 2.6.4.1 Reference Manual and Command ====
996 +==== 2.6.6.1 Reference Manual and Command ====
991 991  
992 992  
993 993  * [[https:~~/~~/enviroprosoilprobes.com/wp-content/uploads/2019/11/ENTELECHY-EP_SDI-12-Commands.pdf>>url:https://enviroprosoilprobes.com/wp-content/uploads/2019/11/ENTELECHY-EP_SDI-12-Commands.pdf]]
... ... @@ -1007,13 +1007,15 @@
1007 1007  
1008 1008  [[image:image-20230627174559-3.png]]
1009 1009  
1010 -==== 2.6.4.2 Hardware Connection to SDI-12-LB ====
1011 1011  
1017 +==== 2.6.6.2 Hardware Connection to SDI-12-LB ====
1018 +
1019 +
1012 1012  [[image:image-20230627174446-2.png]]
1013 1013  
1014 1014  
1015 1015  
1016 -==== 2.6.4.3 Commands set in SDI-12-LB and uplink payload ====
1024 +==== 2.6.6.3 Commands set in SDI-12-LB and uplink payload ====
1017 1017  
1018 1018  
1019 1019  [[image:image-20230627175513-4.png||height="596" width="576"]]
... ... @@ -1025,6 +1025,7 @@
1025 1025  
1026 1026  [[image:image-20230627180303-6.png||height="292" width="1171"]]
1027 1027  
1036 +
1028 1028  == 2.7 Frequency Plans ==
1029 1029  
1030 1030  
... ... @@ -1089,7 +1089,6 @@
1089 1089  
1090 1090  (% style="color:blue" %)**Downlink Command: 0x01**
1091 1091  
1092 -
1093 1093  Format: Command Code (0x01) followed by 3 bytes time value.
1094 1094  
1095 1095  If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01.
... ... @@ -1330,25 +1330,32 @@
1330 1330  
1331 1331  
1332 1332  (((
1333 -(% style="color:blue" %)**Part Number: SDI-12-LB-XXX**
1341 +(% style="color:blue" %)**Part Number: SDI-12-LB-XX-YY**
1334 1334  )))
1335 1335  
1336 1336  (((
1337 -(% style="color:blue" %)**XXX**(%%): The default frequency band
1345 +(% style="color:blue" %)**XX**(%%): The default frequency band
1338 1338  )))
1339 1339  
1340 1340  (((
1341 -(% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band
1342 -(% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band
1343 -(% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band
1344 -(% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band
1345 -(% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band
1346 -(% style="color:red" %)**US915**(%%): LoRaWAN US915 band
1347 -(% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band
1348 -(% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1349 +* (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band
1350 +* (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band
1351 +* (% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band
1352 +* (% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band
1353 +* (% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band
1354 +* (% style="color:red" %)**US915**(%%): LoRaWAN US915 band
1355 +* (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band
1356 +* (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1349 1349  )))
1350 1350  
1359 +(% style="color:blue" %)**YY: **(%%)The grand connector hole size
1351 1351  
1361 +* M12: M12 hole
1362 +* M16: M16 hole
1363 +
1364 +
1365 +
1366 +
1352 1352  = 9. Packing Info =
1353 1353  
1354 1354  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0