From version < 84.1 >
edited by Saxer Lin
on 2023/06/28 09:10
To version < 87.3 >
edited by Xiaoling
on 2023/06/30 10:28
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Saxer
1 +XWiki.Xiaoling
Content
... ... @@ -65,6 +65,8 @@
65 65  * Downlink to change configure
66 66  * 8500mAh Battery for long term use
67 67  
68 +
69 +
68 68  == 1.3 Specification ==
69 69  
70 70  
... ... @@ -77,8 +77,7 @@
77 77  (% style="color:#037691" %)**Common DC Characteristics:**
78 78  
79 79  * Supply Voltage: 2.5v ~~ 3.6v
80 -* Support current: 5V 300mA
81 - 12V 100mA
82 +* Support current: 5V 300mA, 12V 100mA
82 82  * Operating Temperature: -40 ~~ 85°C
83 83  
84 84  (% style="color:#037691" %)**LoRa Spec:**
... ... @@ -113,6 +113,8 @@
113 113  * Sleep Mode: 5uA @ 3.3v
114 114  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
115 115  
117 +
118 +
116 116  == 1.4 Connect to SDI-12 Sensor ==
117 117  
118 118  
... ... @@ -146,6 +146,8 @@
146 146  )))
147 147  |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode.
148 148  
152 +
153 +
149 149  == 1.7 Pin Mapping ==
150 150  
151 151  
... ... @@ -356,7 +356,6 @@
356 356  
357 357  
358 358  
359 -
360 360  ==== (% style="color:blue" %)**aR0!- aR9!,  aRC0!- aRC9!**(%%) ====
361 361  
362 362  
... ... @@ -425,17 +425,25 @@
425 425  [[image:image-20230201092355-17.png||_mstalt="454337" height="426" width="1135"]]
426 426  
427 427  
428 -(% style="color:blue" %)**Example2: **(%%) AT+CFGDEV =0M!,1,1  or  AT+CFGDEV =0C!,1,1
432 +(% style="color:blue" %)**Example2: **(%%) AT+CFGDEV =0M!,1,1
429 429  
430 430  (% style="color:#037691" %)**0M! **(%%): SDI-12 Command,
431 431  
432 432  (% style="color:#037691" %)**1 **(%%): Delay 1 second.  ( 0: 810 mini-second)
433 433  
434 -(% style="color:#037691" %)**1 **(%%):Use aD0! command access.
438 +(% style="color:#037691" %)**1 **(%%): Use aD0! command access.
435 435  
436 436  Equal Downlink: 0xA8 03 30  4D 21 01 01 01
437 437  
438 438  
443 +The following is the display information on the serial port and the server.
444 +
445 +
446 +[[image:image-20230628091055-1.png||height="368" width="462"]]
447 +
448 +[[image:image-20230628091130-2.png||height="258" width="879"]]
449 +
450 +
439 439  === 2.3.3 Convert ASCII to String ===
440 440  
441 441  
... ... @@ -966,6 +966,8 @@
966 966  
967 967  * If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB.
968 968  
981 +
982 +
969 969  ==== 2.6.5.2 Hardware Connection to SDI-12-LB ====
970 970  
971 971  
... ... @@ -1007,8 +1007,10 @@
1007 1007  
1008 1008  [[image:image-20230627174559-3.png]]
1009 1009  
1024 +
1010 1010  ==== 2.6.4.2 Hardware Connection to SDI-12-LB ====
1011 1011  
1027 +
1012 1012  [[image:image-20230627174446-2.png]]
1013 1013  
1014 1014  
... ... @@ -1025,6 +1025,7 @@
1025 1025  
1026 1026  [[image:image-20230627180303-6.png||height="292" width="1171"]]
1027 1027  
1044 +
1028 1028  == 2.7 Frequency Plans ==
1029 1029  
1030 1030  
... ... @@ -1089,7 +1089,6 @@
1089 1089  
1090 1090  (% style="color:blue" %)**Downlink Command: 0x01**
1091 1091  
1092 -
1093 1093  Format: Command Code (0x01) followed by 3 bytes time value.
1094 1094  
1095 1095  If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01.
... ... @@ -1097,6 +1097,8 @@
1097 1097  * Example 1: Downlink Payload: 0100001E  ~/~/ Set Transmit Interval (TDC) = 30 seconds
1098 1098  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
1099 1099  
1116 +
1117 +
1100 1100  == 3.2 Set Interrupt Mode ==
1101 1101  
1102 1102  
... ... @@ -1128,6 +1128,8 @@
1128 1128  * Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
1129 1129  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
1130 1130  
1149 +
1150 +
1131 1131  == 3.3 Set the output time ==
1132 1132  
1133 1133  
... ... @@ -1199,6 +1199,8 @@
1199 1199  * Example 5: Downlink Payload: 070301F4  **~-~-->**  AT+12VT=500
1200 1200  * Example 6: Downlink Payload: 07030000  **~-~-->**  AT+12VT=0
1201 1201  
1222 +
1223 +
1202 1202  == 3.4 Set the all data mode ==
1203 1203  
1204 1204  
... ... @@ -1221,6 +1221,8 @@
1221 1221  * Example 1: Downlink Payload: AB 00  ~/~/  AT+ALLDATAMOD=0
1222 1222  * Example 2: Downlink Payload: AB 01  ~/~/  AT+ALLDATAMOD=1
1223 1223  
1246 +
1247 +
1224 1224  == 3.5 Set the splicing payload for uplink ==
1225 1225  
1226 1226  
... ... @@ -1277,6 +1277,8 @@
1277 1277  * Example 1: Downlink Payload: AE 01  ~/~/  AT+PAYVER=1
1278 1278  * Example 2: Downlink Payload: AE 05  ~/~/  AT+PAYVER=5
1279 1279  
1304 +
1305 +
1280 1280  = 4. Battery & Power Consumption =
1281 1281  
1282 1282  
... ... @@ -1363,6 +1363,8 @@
1363 1363  * Package Size / pcs : cm
1364 1364  * Weight / pcs : g
1365 1365  
1392 +
1393 +
1366 1366  = 10. ​Support =
1367 1367  
1368 1368  
image-20230628091130-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Saxer
Size
... ... @@ -1,0 +1,1 @@
1 +84.0 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0