Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Mengting Qiu on 2025/07/03 15:42
From version 80.1
edited by Bei Jinggeng
on 2023/06/27 18:03
on 2023/06/27 18:03
Change comment:
Uploaded new attachment "image-20230627180303-6.png", version {1}
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.Xiaoling - Content
-
... ... @@ -66,7 +66,6 @@ 66 66 * 8500mAh Battery for long term use 67 67 68 68 69 - 70 70 == 1.3 Specification == 71 71 72 72 ... ... @@ -79,8 +79,7 @@ 79 79 (% style="color:#037691" %)**Common DC Characteristics:** 80 80 81 81 * Supply Voltage: 2.5v ~~ 3.6v 82 -* Support current: 5V 300mA 83 - 12V 100mA 81 +* Support current: 5V 300mA, 12V 100mA 84 84 * Operating Temperature: -40 ~~ 85°C 85 85 86 86 (% style="color:#037691" %)**LoRa Spec:** ... ... @@ -116,7 +116,6 @@ 116 116 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 117 117 118 118 119 - 120 120 == 1.4 Connect to SDI-12 Sensor == 121 121 122 122 ... ... @@ -151,7 +151,6 @@ 151 151 |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode. 152 152 153 153 154 - 155 155 == 1.7 Pin Mapping == 156 156 157 157 ... ... @@ -362,7 +362,6 @@ 362 362 363 363 364 364 365 - 366 366 ==== (% style="color:blue" %)**aR0!- aR9!, aRC0!- aRC9!**(%%) ==== 367 367 368 368 ... ... @@ -431,17 +431,25 @@ 431 431 [[image:image-20230201092355-17.png||_mstalt="454337" height="426" width="1135"]] 432 432 433 433 434 -(% style="color:blue" %)**Example2: **(%%) AT+CFGDEV =0M!,1,1 or AT+CFGDEV =0C!,1,1429 +(% style="color:blue" %)**Example2: **(%%) AT+CFGDEV =0M!,1,1 435 435 436 436 (% style="color:#037691" %)**0M! **(%%): SDI-12 Command, 437 437 438 438 (% style="color:#037691" %)**1 **(%%): Delay 1 second. ( 0: 810 mini-second) 439 439 440 -(% style="color:#037691" %)**1 **(%%):Use aD0! command access. 435 +(% style="color:#037691" %)**1 **(%%): Use aD0! command access. 441 441 442 442 Equal Downlink: 0xA8 03 30 4D 21 01 01 01 443 443 444 444 440 +The following is the display information on the serial port and the server. 441 + 442 + 443 +[[image:image-20230628091055-1.png||height="368" width="462"]] 444 + 445 +[[image:image-20230628091130-2.png||height="258" width="879"]] 446 + 447 + 445 445 === 2.3.3 Convert ASCII to String === 446 446 447 447 ... ... @@ -910,7 +910,7 @@ 910 910 911 911 [[image:image-20230603121721-9.png]] 912 912 913 -[[image:image-20230603 121752-10.png]]916 +[[image:image-20230628090323-1.png||height="414" width="694"]] 914 914 915 915 Data in TTN: 916 916 ... ... @@ -918,7 +918,7 @@ 918 918 919 919 920 920 921 -=== (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.4 Example 4 ~-~- Connect to TEROS-12 ===924 +=== 2.6.4 Example 4 ~-~- Connect to TEROS-12 === 922 922 923 923 ==== 2.6.4.1 Reference Manual and Command ==== 924 924 ... ... @@ -959,7 +959,7 @@ 959 959 [[image:image-20230603122139-14.png||height="148" width="1128"]] 960 960 961 961 962 -=== (% id="cke_bm_1489640S" style="display:none" %) (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.5 Example 5 ~-~- Connect to SIL-400/TEROS-12 & Hygrovue10 ===965 +=== 2.6.5 Example 5 ~-~- Connect to SIL-400/TEROS-12 & Hygrovue10 === 963 963 964 964 ==== 2.6.5.1 Important Notice! ==== 965 965 ... ... @@ -973,7 +973,6 @@ 973 973 * If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB. 974 974 975 975 976 - 977 977 ==== 2.6.5.2 Hardware Connection to SDI-12-LB ==== 978 978 979 979 ... ... @@ -993,6 +993,49 @@ 993 993 [[image:image-20230603122719-20.png||height="151" width="1179"]] 994 994 995 995 998 +=== 2.6.6 Example 6 ~-~- Connect to ENTELECHY-EP_SDI-12 === 999 + 1000 +==== 2.6.6.1 Reference Manual and Command ==== 1001 + 1002 + 1003 +* [[https:~~/~~/enviroprosoilprobes.com/wp-content/uploads/2019/11/ENTELECHY-EP_SDI-12-Commands.pdf>>url:https://enviroprosoilprobes.com/wp-content/uploads/2019/11/ENTELECHY-EP_SDI-12-Commands.pdf]] 1004 + 1005 +* Commands to be used in PC and output. 1006 + 1007 +1.check device address 1008 + 1009 +2.change device address 1010 + 1011 +3.check device ID 1012 + 1013 +4.start measure 1014 + 1015 +5.Get Meausre result 1016 + 1017 + 1018 +[[image:image-20230627174559-3.png]] 1019 + 1020 + 1021 +==== 2.6.6.2 Hardware Connection to SDI-12-LB ==== 1022 + 1023 + 1024 +[[image:image-20230627174446-2.png]] 1025 + 1026 + 1027 + 1028 +==== 2.6.6.3 Commands set in SDI-12-LB and uplink payload ==== 1029 + 1030 + 1031 +[[image:image-20230627175513-4.png||height="596" width="576"]] 1032 + 1033 +[[image:image-20230627175736-5.png||height="429" width="693"]] 1034 + 1035 + 1036 +**Data in TTN:** 1037 + 1038 +[[image:image-20230627180303-6.png||height="292" width="1171"]] 1039 + 1040 + 996 996 == 2.7 Frequency Plans == 997 997 998 998 ... ... @@ -1057,7 +1057,6 @@ 1057 1057 1058 1058 (% style="color:blue" %)**Downlink Command: 0x01** 1059 1059 1060 - 1061 1061 Format: Command Code (0x01) followed by 3 bytes time value. 1062 1062 1063 1063 If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01. ... ... @@ -1066,7 +1066,6 @@ 1066 1066 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1067 1067 1068 1068 1069 - 1070 1070 == 3.2 Set Interrupt Mode == 1071 1071 1072 1072 ... ... @@ -1099,7 +1099,6 @@ 1099 1099 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1100 1100 1101 1101 1102 - 1103 1103 == 3.3 Set the output time == 1104 1104 1105 1105 ... ... @@ -1172,7 +1172,6 @@ 1172 1172 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 1173 1173 1174 1174 1175 - 1176 1176 == 3.4 Set the all data mode == 1177 1177 1178 1178 ... ... @@ -1196,7 +1196,6 @@ 1196 1196 * Example 2: Downlink Payload: AB 01 ~/~/ AT+ALLDATAMOD=1 1197 1197 1198 1198 1199 - 1200 1200 == 3.5 Set the splicing payload for uplink == 1201 1201 1202 1202 ... ... @@ -1254,7 +1254,6 @@ 1254 1254 * Example 2: Downlink Payload: AE 05 ~/~/ AT+PAYVER=5 1255 1255 1256 1256 1257 - 1258 1258 = 4. Battery & Power Consumption = 1259 1259 1260 1260 ... ... @@ -1342,7 +1342,6 @@ 1342 1342 * Weight / pcs : g 1343 1343 1344 1344 1345 - 1346 1346 = 10. Support = 1347 1347 1348 1348
- image-20230628090323-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Saxer - Size
-
... ... @@ -1,0 +1,1 @@ 1 +137.2 KB - Content
- image-20230628091055-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Saxer - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.9 KB - Content
- image-20230628091130-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Saxer - Size
-
... ... @@ -1,0 +1,1 @@ 1 +84.0 KB - Content