... ... @@ -66,7 +66,6 @@
66 66  * 8500mAh Battery for long term use
67 67  
68 68  
69 -
70 70  == 1.3 Specification ==
71 71  
72 72  
... ... @@ -79,8 +79,7 @@
79 79  (% style="color:#037691" %)**Common DC Characteristics:**
80 80  
81 81  * Supply Voltage: 2.5v ~~ 3.6v
82 -* Support current: 5V 300mA
83 - 12V 100mA
81 +* Support current: 5V 300mA, 12V 100mA
84 84  * Operating Temperature: -40 ~~ 85°C
85 85  
86 86  (% style="color:#037691" %)**LoRa Spec:**
... ... @@ -116,7 +116,6 @@
116 116  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
117 117  
118 118  
119 -
120 120  == 1.4 Connect to SDI-12 Sensor ==
121 121  
122 122  
... ... @@ -151,7 +151,6 @@
151 151  |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode.
152 152  
153 153  
154 -
155 155  == 1.7 Pin Mapping ==
156 156  
157 157  
... ... @@ -362,7 +362,6 @@
362 362  
363 363  
364 364  
365 -
366 366  ==== (% style="color:blue" %)**aR0!- aR9!,  aRC0!- aRC9!**(%%) ====
367 367  
368 368  
... ... @@ -431,17 +431,25 @@
431 431  [[image:image-20230201092355-17.png||_mstalt="454337" height="426" width="1135"]]
432 432  
433 433  
434 -(% style="color:blue" %)**Example2: **(%%) AT+CFGDEV =0M!,1,1  or  AT+CFGDEV =0C!,1,1
429 +(% style="color:blue" %)**Example2: **(%%) AT+CFGDEV =0M!,1,1
435 435  
436 436  (% style="color:#037691" %)**0M! **(%%): SDI-12 Command,
437 437  
438 438  (% style="color:#037691" %)**1 **(%%): Delay 1 second.  ( 0: 810 mini-second)
439 439  
440 -(% style="color:#037691" %)**1 **(%%):Use aD0! command access.
435 +(% style="color:#037691" %)**1 **(%%): Use aD0! command access.
441 441  
442 442  Equal Downlink: 0xA8 03 30  4D 21 01 01 01
443 443  
444 444  
440 +The following is the display information on the serial port and the server.
441 +
442 +
443 +[[image:image-20230628091055-1.png||height="368" width="462"]]
444 +
445 +[[image:image-20230628091130-2.png||height="258" width="879"]]
446 +
447 +
445 445  === 2.3.3 Convert ASCII to String ===
446 446  
447 447  
... ... @@ -910,7 +910,7 @@
910 910  
911 911  [[image:image-20230603121721-9.png]]
912 912  
913 -[[image:image-20230603121752-10.png]]
916 +[[image:image-20230628090323-1.png||height="414" width="694"]]
914 914  
915 915  Data in TTN:
916 916  
... ... @@ -918,7 +918,7 @@
918 918  
919 919  
920 920  
921 -=== (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.4 Example 4 ~-~- Connect to TEROS-12 ===
924 +=== 2.6.4 Example 4 ~-~- Connect to TEROS-12 ===
922 922  
923 923  ==== 2.6.4.1 Reference Manual and Command ====
924 924  
... ... @@ -959,7 +959,7 @@
959 959  [[image:image-20230603122139-14.png||height="148" width="1128"]]
960 960  
961 961  
962 -=== (% id="cke_bm_1489640S" style="display:none" %) (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.5 Example 5 ~-~- Connect to SIL-400/TEROS-12 & Hygrovue10 ===
965 +=== 2.6.5 Example 5 ~-~- Connect to SIL-400/TEROS-12 & Hygrovue10 ===
963 963  
964 964  ==== 2.6.5.1 Important Notice! ====
965 965  
... ... @@ -973,7 +973,6 @@
973 973  * If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB.
974 974  
975 975  
976 -
977 977  ==== 2.6.5.2 Hardware Connection to SDI-12-LB ====
978 978  
979 979  
... ... @@ -993,6 +993,49 @@
993 993  [[image:image-20230603122719-20.png||height="151" width="1179"]]
994 994  
995 995  
998 +=== 2.6.6 Example 6 ~-~- Connect to ENTELECHY-EP_SDI-12 ===
999 +
1000 +==== 2.6.6.1 Reference Manual and Command ====
1001 +
1002 +
1003 +* [[https:~~/~~/enviroprosoilprobes.com/wp-content/uploads/2019/11/ENTELECHY-EP_SDI-12-Commands.pdf>>url:https://enviroprosoilprobes.com/wp-content/uploads/2019/11/ENTELECHY-EP_SDI-12-Commands.pdf]]
1004 +
1005 +* Commands to be used in PC and output.
1006 +
1007 +1.check device address
1008 +
1009 +2.change device address
1010 +
1011 +3.check device ID
1012 +
1013 +4.start measure
1014 +
1015 +5.Get Meausre result
1016 +
1017 +
1018 +[[image:image-20230627174559-3.png]]
1019 +
1020 +
1021 +==== 2.6.6.2 Hardware Connection to SDI-12-LB ====
1022 +
1023 +
1024 +[[image:image-20230627174446-2.png]]
1025 +
1026 +
1027 +
1028 +==== 2.6.6.3 Commands set in SDI-12-LB and uplink payload ====
1029 +
1030 +
1031 +[[image:image-20230627175513-4.png||height="596" width="576"]]
1032 +
1033 +[[image:image-20230627175736-5.png||height="429" width="693"]]
1034 +
1035 +
1036 +**Data in TTN:**
1037 +
1038 +[[image:image-20230627180303-6.png||height="292" width="1171"]]
1039 +
1040 +
996 996  == 2.7 Frequency Plans ==
997 997  
998 998  
... ... @@ -1057,7 +1057,6 @@
1057 1057  
1058 1058  (% style="color:blue" %)**Downlink Command: 0x01**
1059 1059  
1060 -
1061 1061  Format: Command Code (0x01) followed by 3 bytes time value.
1062 1062  
1063 1063  If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01.
... ... @@ -1066,7 +1066,6 @@
1066 1066  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
1067 1067  
1068 1068  
1069 -
1070 1070  == 3.2 Set Interrupt Mode ==
1071 1071  
1072 1072  
... ... @@ -1099,7 +1099,6 @@
1099 1099  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
1100 1100  
1101 1101  
1102 -
1103 1103  == 3.3 Set the output time ==
1104 1104  
1105 1105  
... ... @@ -1172,7 +1172,6 @@
1172 1172  * Example 6: Downlink Payload: 07030000  **~-~-->**  AT+12VT=0
1173 1173  
1174 1174  
1175 -
1176 1176  == 3.4 Set the all data mode ==
1177 1177  
1178 1178  
... ... @@ -1196,7 +1196,6 @@
1196 1196  * Example 2: Downlink Payload: AB 01  ~/~/  AT+ALLDATAMOD=1
1197 1197  
1198 1198  
1199 -
1200 1200  == 3.5 Set the splicing payload for uplink ==
1201 1201  
1202 1202  
... ... @@ -1254,7 +1254,6 @@
1254 1254  * Example 2: Downlink Payload: AE 05  ~/~/  AT+PAYVER=5
1255 1255  
1256 1256  
1257 -
1258 1258  = 4. Battery & Power Consumption =
1259 1259  
1260 1260  
... ... @@ -1342,7 +1342,6 @@
1342 1342  * Weight / pcs : g
1343 1343  
1344 1344  
1345 -
1346 1346  = 10. ​Support =
1347 1347  
1348 1348  
image-20230628090323-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Saxer
Size
... ... @@ -1,0 +1,1 @@
1 +137.2 KB
Content
image-20230628091055-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Saxer
Size
... ... @@ -1,0 +1,1 @@
1 +24.9 KB
Content
image-20230628091130-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Saxer
Size
... ... @@ -1,0 +1,1 @@
1 +84.0 KB
Content