Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Xiaoling on 2025/04/25 08:58
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -66,7 +66,6 @@ 66 66 * 8500mAh Battery for long term use 67 67 68 68 69 - 70 70 == 1.3 Specification == 71 71 72 72 ... ... @@ -116,7 +116,6 @@ 116 116 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 117 117 118 118 119 - 120 120 == 1.4 Connect to SDI-12 Sensor == 121 121 122 122 ... ... @@ -151,7 +151,6 @@ 151 151 |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode. 152 152 153 153 154 - 155 155 == 1.7 Pin Mapping == 156 156 157 157 ... ... @@ -973,7 +973,6 @@ 973 973 * If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB. 974 974 975 975 976 - 977 977 ==== 2.6.5.2 Hardware Connection to SDI-12-LB ==== 978 978 979 979 ... ... @@ -993,6 +993,46 @@ 993 993 [[image:image-20230603122719-20.png||height="151" width="1179"]] 994 994 995 995 992 +=== (% id="cke_bm_4783S" style="display:none" %) (%%)2.6.6 Example 6 ~-~- Connect to ENTELECHY-EP_SDI-12 === 993 + 994 +==== 2.6.4.1 Reference Manual and Command ==== 995 + 996 + 997 +* [[https:~~/~~/enviroprosoilprobes.com/wp-content/uploads/2019/11/ENTELECHY-EP_SDI-12-Commands.pdf>>url:https://enviroprosoilprobes.com/wp-content/uploads/2019/11/ENTELECHY-EP_SDI-12-Commands.pdf]] 998 + 999 +* Commands to be used in PC and output. 1000 + 1001 +1.check device address 1002 + 1003 +2.change device address 1004 + 1005 +3.check device ID 1006 + 1007 +4.start measure 1008 + 1009 +5.Get Meausre result 1010 + 1011 + 1012 +[[image:image-20230627174559-3.png]] 1013 + 1014 +==== 2.6.4.2 Hardware Connection to SDI-12-LB ==== 1015 + 1016 +[[image:image-20230627174446-2.png]] 1017 + 1018 + 1019 + 1020 +==== 2.6.4.3 Commands set in SDI-12-LB and uplink payload ==== 1021 + 1022 + 1023 +[[image:image-20230627175513-4.png||height="596" width="576"]] 1024 + 1025 +[[image:image-20230627175736-5.png||height="429" width="693"]] 1026 + 1027 + 1028 +**Data in TTN:** 1029 + 1030 +[[image:image-20230627180303-6.png||height="292" width="1171"]] 1031 + 996 996 == 2.7 Frequency Plans == 997 997 998 998 ... ... @@ -1066,7 +1066,6 @@ 1066 1066 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1067 1067 1068 1068 1069 - 1070 1070 == 3.2 Set Interrupt Mode == 1071 1071 1072 1072 ... ... @@ -1099,7 +1099,6 @@ 1099 1099 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1100 1100 1101 1101 1102 - 1103 1103 == 3.3 Set the output time == 1104 1104 1105 1105 ... ... @@ -1172,7 +1172,6 @@ 1172 1172 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 1173 1173 1174 1174 1175 - 1176 1176 == 3.4 Set the all data mode == 1177 1177 1178 1178 ... ... @@ -1196,7 +1196,6 @@ 1196 1196 * Example 2: Downlink Payload: AB 01 ~/~/ AT+ALLDATAMOD=1 1197 1197 1198 1198 1199 - 1200 1200 == 3.5 Set the splicing payload for uplink == 1201 1201 1202 1202 ... ... @@ -1254,7 +1254,6 @@ 1254 1254 * Example 2: Downlink Payload: AE 05 ~/~/ AT+PAYVER=5 1255 1255 1256 1256 1257 - 1258 1258 = 4. Battery & Power Consumption = 1259 1259 1260 1260 ... ... @@ -1342,7 +1342,6 @@ 1342 1342 * Weight / pcs : g 1343 1343 1344 1344 1345 - 1346 1346 = 10. Support = 1347 1347 1348 1348