Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Mengting Qiu on 2025/07/03 15:42
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Saxer - Content
-
... ... @@ -66,7 +66,6 @@ 66 66 * 8500mAh Battery for long term use 67 67 68 68 69 - 70 70 == 1.3 Specification == 71 71 72 72 ... ... @@ -116,10 +116,10 @@ 116 116 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 117 117 118 118 119 - 120 120 == 1.4 Connect to SDI-12 Sensor == 121 121 122 122 121 + 123 123 [[image:1675212538524-889.png||_mstalt="298272"]] 124 124 125 125 ... ... @@ -151,7 +151,6 @@ 151 151 |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode. 152 152 153 153 154 - 155 155 == 1.7 Pin Mapping == 156 156 157 157 ... ... @@ -206,6 +206,7 @@ 206 206 207 207 Each SDI-12-LB is shipped with a sticker with the default device EUI as below: 208 208 207 + 209 209 [[image:image-20230426084456-1.png||height="241" width="519"]] 210 210 211 211 ... ... @@ -647,33 +647,33 @@ 647 647 648 648 (% style="color:#037691" %)**Frequency Band**: 649 649 650 -0x01: EU868 649 +*0x01: EU868 651 651 652 -0x02: US915 651 +*0x02: US915 653 653 654 -0x03: IN865 653 +*0x03: IN865 655 655 656 -0x04: AU915 655 +*0x04: AU915 657 657 658 -0x05: KZ865 657 +*0x05: KZ865 659 659 660 -0x06: RU864 659 +*0x06: RU864 661 661 662 -0x07: AS923 661 +*0x07: AS923 663 663 664 -0x08: AS923-1 663 +*0x08: AS923-1 665 665 666 -0x09: AS923-2 665 +*0x09: AS923-2 667 667 668 -0x0a: AS923-3 667 +*0x0a: AS923-3 669 669 670 -0x0b: CN470 669 +*0x0b: CN470 671 671 672 -0x0c: EU433 671 +*0x0c: EU433 673 673 674 -0x0d: KR920 673 +*0x0d: KR920 675 675 676 -0x0e: MA869 675 +*0x0e: MA869 677 677 678 678 679 679 (% style="color:#037691" %)**Sub-Band**: ... ... @@ -704,9 +704,9 @@ 704 704 * Periodically Uplink: FPORT=2 705 705 706 706 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %) 707 -|=(% style="width: 90px;background-color:#D9E2F3 ;color:#0070C0" %)(((706 +|=(% style="width: 90px;background-color:#D9E2F3" %)((( 708 708 **Size(bytes)** 709 -)))|=(% style="width: 80px;background-color:#D9E2F3 ;color:#0070C0" %)**2**|=(% style="width: 90px;background-color:#D9E2F3;color:#0070C0" %)**1**|=(% style="width: 240px;background-color:#D9E2F3;color:#0070C0" %)**Length depends on the return from the commands**708 +)))|=(% style="width: 80px;background-color:#D9E2F3" %)**2**|=(% style="width: 90px;background-color:#D9E2F3" %)**1**|=(% style="width: 240px;background-color:#D9E2F3" %)**Length depends on the return from the commands** 710 710 |(% style="width:93px" %)**Value**|(% style="width:83px" %)((( 711 711 Battery(mV) 712 712 & ... ... @@ -971,6 +971,7 @@ 971 971 972 972 * If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB. 973 973 973 + 974 974 ==== 2.6.5.2 Hardware Connection to SDI-12-LB ==== 975 975 976 976 ... ... @@ -1062,6 +1062,7 @@ 1062 1062 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 1063 1063 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1064 1064 1065 + 1065 1065 == 3.2 Set Interrupt Mode == 1066 1066 1067 1067 ... ... @@ -1093,6 +1093,7 @@ 1093 1093 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 1094 1094 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1095 1095 1097 + 1096 1096 == 3.3 Set the output time == 1097 1097 1098 1098 ... ... @@ -1164,6 +1164,7 @@ 1164 1164 * Example 5: Downlink Payload: 070301F4 **~-~-->** AT+12VT=500 1165 1165 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 1166 1166 1169 + 1167 1167 == 3.4 Set the all data mode == 1168 1168 1169 1169 ... ... @@ -1186,6 +1186,7 @@ 1186 1186 * Example 1: Downlink Payload: AB 00 ~/~/ AT+ALLDATAMOD=0 1187 1187 * Example 2: Downlink Payload: AB 01 ~/~/ AT+ALLDATAMOD=1 1188 1188 1192 + 1189 1189 == 3.5 Set the splicing payload for uplink == 1190 1190 1191 1191 ... ... @@ -1242,6 +1242,7 @@ 1242 1242 * Example 1: Downlink Payload: AE 01 ~/~/ AT+PAYVER=1 1243 1243 * Example 2: Downlink Payload: AE 05 ~/~/ AT+PAYVER=5 1244 1244 1249 + 1245 1245 = 4. Battery & Power Consumption = 1246 1246 1247 1247 ... ... @@ -1328,6 +1328,7 @@ 1328 1328 * Package Size / pcs : cm 1329 1329 * Weight / pcs : g 1330 1330 1336 + 1331 1331 = 10. Support = 1332 1332 1333 1333