Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Xiaoling on 2025/04/25 08:58
Change comment:
Uploaded new attachment "image-20230603122719-20.png", version {1}
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Edwin - Content
-
... ... @@ -66,7 +66,6 @@ 66 66 * 8500mAh Battery for long term use 67 67 68 68 69 - 70 70 == 1.3 Specification == 71 71 72 72 ... ... @@ -116,10 +116,10 @@ 116 116 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 117 117 118 118 119 - 120 120 == 1.4 Connect to SDI-12 Sensor == 121 121 122 122 121 + 123 123 [[image:1675212538524-889.png||_mstalt="298272"]] 124 124 125 125 ... ... @@ -151,7 +151,6 @@ 151 151 |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode. 152 152 153 153 154 - 155 155 == 1.7 Pin Mapping == 156 156 157 157 ... ... @@ -206,6 +206,7 @@ 206 206 207 207 Each SDI-12-LB is shipped with a sticker with the default device EUI as below: 208 208 207 + 209 209 [[image:image-20230426084456-1.png||height="241" width="519"]] 210 210 211 211 ... ... @@ -400,7 +400,7 @@ 400 400 This command can be used to debug all SDI-12 command. 401 401 402 402 403 -LoRaWAN Downlink: A8 aa xx xx xx xx bb cc dd402 +LoRaWAN Downlink: A8 aa xx xx xx xx bb cc 404 404 405 405 (% style="color:#037691" %)**aa **(%%): total SDI-12 command length 406 406 ... ... @@ -410,11 +410,9 @@ 410 410 411 411 (% style="color:#037691" %)**cc **(%%): 0: don't uplink return to LoRaWAN, 1: Uplink return to LoRaWAN on FPORT=100 412 412 413 -(% style="color:#037691" %)**dd: **(%%) 0: Do not use aD0! command access, 1: use aD0! command access. 414 414 413 +(% style="color:blue" %)**Example: **(%%) AT+CFGDEV =0RC0!,1 415 415 416 -(% style="color:blue" %)**Example1: **(%%) AT+CFGDEV =0RC0!,1 417 - 418 418 (% style="color:#037691" %)**0RC0! **(%%): SDI-12 Command, 419 419 420 420 (% style="color:#037691" %)**1 **(%%): Delay 1 second. ( 0: 810 mini-second) ... ... @@ -431,17 +431,6 @@ 431 431 [[image:image-20230201092355-17.png||_mstalt="454337" height="426" width="1135"]] 432 432 433 433 434 -(% style="color:blue" %)**Example2: **(%%) AT+CFGDEV =0M!,1,1 or AT+CFGDEV =0C!,1,1 435 - 436 -(% style="color:#037691" %)**0M! **(%%): SDI-12 Command, 437 - 438 -(% style="color:#037691" %)**1 **(%%): Delay 1 second. ( 0: 810 mini-second) 439 - 440 -(% style="color:#037691" %)**1 **(%%):Use aD0! command access. 441 - 442 -Equal Downlink: 0xA8 03 30 4D 21 01 01 01 443 - 444 - 445 445 === 2.3.3 Convert ASCII to String === 446 446 447 447 ... ... @@ -647,33 +647,33 @@ 647 647 648 648 (% style="color:#037691" %)**Frequency Band**: 649 649 650 -0x01: EU868 636 +*0x01: EU868 651 651 652 -0x02: US915 638 +*0x02: US915 653 653 654 -0x03: IN865 640 +*0x03: IN865 655 655 656 -0x04: AU915 642 +*0x04: AU915 657 657 658 -0x05: KZ865 644 +*0x05: KZ865 659 659 660 -0x06: RU864 646 +*0x06: RU864 661 661 662 -0x07: AS923 648 +*0x07: AS923 663 663 664 -0x08: AS923-1 650 +*0x08: AS923-1 665 665 666 -0x09: AS923-2 652 +*0x09: AS923-2 667 667 668 -0x0a: AS923-3 654 +*0x0a: AS923-3 669 669 670 -0x0b: CN470 656 +*0x0b: CN470 671 671 672 -0x0c: EU433 658 +*0x0c: EU433 673 673 674 -0x0d: KR920 660 +*0x0d: KR920 675 675 676 -0x0e: MA869 662 +*0x0e: MA869 677 677 678 678 679 679 (% style="color:#037691" %)**Sub-Band**: ... ... @@ -704,9 +704,9 @@ 704 704 * Periodically Uplink: FPORT=2 705 705 706 706 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %) 707 -|=(% style="width: 90px;background-color:#D9E2F3 ;color:#0070C0" %)(((693 +|=(% style="width: 90px;background-color:#D9E2F3" %)((( 708 708 **Size(bytes)** 709 -)))|=(% style="width: 80px;background-color:#D9E2F3 ;color:#0070C0" %)**2**|=(% style="width: 90px;background-color:#D9E2F3;color:#0070C0" %)**1**|=(% style="width: 240px;background-color:#D9E2F3;color:#0070C0" %)**Length depends on the return from the commands**695 +)))|=(% style="width: 80px;background-color:#D9E2F3" %)**2**|=(% style="width: 90px;background-color:#D9E2F3" %)**1**|=(% style="width: 240px;background-color:#D9E2F3" %)**Length depends on the return from the commands** 710 710 |(% style="width:93px" %)**Value**|(% style="width:83px" %)((( 711 711 Battery(mV) 712 712 & ... ... @@ -836,24 +836,22 @@ 836 836 Partial cut, the cut sensor address and the first two parameters:(% style="color:#037691" %)**AT+DATACUTx=25,2,1~~12, cut out the character field ” 4+30.8+22.84”**. 837 837 838 838 839 -=== 2.6.2 Example 2~-~- Connect to Hygrovue10 ===825 +=== 2.6.2 Example ~-~- Connect to Hygrovue10 === 840 840 841 841 ==== 2.6.2.1 Reference Manual and Command ==== 842 842 843 - 844 844 * [[Hygrovue10 Product Page>>https://www.campbellsci.com/hygrovue10]] 845 - 846 846 * Commands to be used in PC and output. 847 847 848 - ~1.832 +1.check device address 849 849 850 -2. 834 +2.change device address 851 851 852 -3. 836 +3.check device ID 853 853 854 -4. 838 +4.start measure 855 855 856 -5. 840 +5.Get Meausre result 857 857 858 858 [[image:image-20230603120209-2.png||height="281" width="267"]] 859 859 ... ... @@ -860,136 +860,22 @@ 860 860 861 861 ==== 2.6.2.2 Hardware Connection to SDI-12-LB ==== 862 862 863 - 864 864 [[image:image-20230603120515-3.png]] 865 865 866 866 867 867 ==== 2.6.2.3 Commands set in SDI-12-LB and uplink payload ==== 868 868 869 - 870 870 [[image:image-20230603120648-4.png]] 871 871 872 872 [[image:image-20230603120726-5.png]] 873 873 856 +Data in TTN: 874 874 875 -**Data in TTN:** 876 - 877 877 [[image:image-20230603120859-6.png||height="118" width="1285"]] 878 878 879 879 880 -=== (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.3 Example 3 ~-~- Connect to SIL-400 === 881 881 882 -==== 2.6.3.1 Reference Manual and Command ==== 883 883 884 - 885 -* [[SIL-400 Product Page>>https://www.apogeeinstruments.com/sil-411-commercial-grade-sdi-12-digital-output-standard-field-of-view-infrared-radiometer-sensor/]] 886 - 887 -* Commands to be used in PC and output. 888 - 889 -~1. check device address 890 - 891 -2. change device address 892 - 893 -3. check device ID 894 - 895 -4. start measure 896 - 897 -5. Get Meausre result 898 - 899 -[[image:image-20230603121606-7.png||height="242" width="307"]] 900 - 901 - 902 -==== 2.6.3.2 Hardware Connection to SDI-12-LB ==== 903 - 904 - 905 -[[image:image-20230603121643-8.png||height="442" width="656"]] 906 - 907 - 908 -==== 2.6.3.3 Commands set in SDI-12-LB and uplink payload ==== 909 - 910 - 911 -[[image:image-20230603121721-9.png]] 912 - 913 -[[image:image-20230603121752-10.png]] 914 - 915 -Data in TTN: 916 - 917 -[[image:image-20230603121826-11.png||height="155" width="1104"]] 918 - 919 - 920 - 921 -=== (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.4 Example 4 ~-~- Connect to TEROS-12 === 922 - 923 -==== 2.6.4.1 Reference Manual and Command ==== 924 - 925 - 926 -* [[TEROS-12 Product Page>>https://www.metergroup.com/en/meter-environment/products/teros-12-soil-moisture-sensor]] 927 - 928 -* Commands to be used in PC and output. 929 - 930 -1.check device address 931 - 932 -2.change device address 933 - 934 -3.check device ID 935 - 936 -4.start measure 937 - 938 -5.Get Meausre result 939 - 940 -[[image:image-20230603122248-16.png||height="196" width="198"]] 941 - 942 - 943 -==== 2.6.4.2 Hardware Connection to SDI-12-LB ==== 944 - 945 - 946 -[[image:image-20230603122212-15.png||height="502" width="667"]] 947 - 948 - 949 -==== 2.6.4.3 Commands set in SDI-12-LB and uplink payload ==== 950 - 951 -[[image:image-20230603122040-12.png]] 952 - 953 -[[image:image-20230603122109-13.png||height="469" width="762"]] 954 - 955 - 956 -**Data in TTN:** 957 - 958 -[[image:image-20230603122139-14.png||height="148" width="1128"]] 959 - 960 - 961 -=== (% id="cke_bm_1489640S" style="display:none" %) (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.5 Example 5 ~-~- Connect to SIL-400/TEROS-12 & Hygrovue10 === 962 - 963 -==== 2.6.5.1 Important Notice! ==== 964 - 965 - 966 -* The product page and reference command see above example 2,3,4 967 - 968 -* All of these SDI-12 sensors use the same address (address 0) by default. So we need to change their address to different address, by using **aAb!** command. See above example. 969 - 970 -* The sensor needs to be powered to a steady statue. So the 12VT time need to be set to the maximum stable time for the sensors. in this example, it is 13 seconds. 971 - 972 -* If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB. 973 - 974 -==== 2.6.5.2 Hardware Connection to SDI-12-LB ==== 975 - 976 - 977 -[[image:image-20230603122508-17.png||height="526" width="742"]] 978 - 979 - 980 -==== 2.6.5.3 Commands set in SDI-12-LB and uplink payload ==== 981 - 982 - 983 -[[image:image-20230603122549-18.png]] 984 - 985 -[[image:image-20230603122623-19.png||height="483" width="1121"]] 986 - 987 - 988 -**Data in TTN:** 989 - 990 -[[image:image-20230603122719-20.png||height="151" width="1179"]] 991 - 992 - 993 993 == 2.7 Frequency Plans == 994 994 995 995 ... ... @@ -1062,6 +1062,7 @@ 1062 1062 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 1063 1063 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1064 1064 935 + 1065 1065 == 3.2 Set Interrupt Mode == 1066 1066 1067 1067 ... ... @@ -1093,6 +1093,7 @@ 1093 1093 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 1094 1094 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1095 1095 967 + 1096 1096 == 3.3 Set the output time == 1097 1097 1098 1098 ... ... @@ -1136,10 +1136,8 @@ 1136 1136 OK 1137 1137 ))) 1138 1138 1139 -(% style="color:blue" %)**AT Command: AT+12VT 1011 +(% style="color:blue" %)**AT Command: AT+12VT** 1140 1140 1141 -(% style="color:blue" %)**(The v1.2 version is enabled for 1 second by default, and the version below v1.2 is disabled by default)** 1142 - 1143 1143 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:443px" %) 1144 1144 |=(% style="width: 156px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 199px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 83px;background-color:#D9E2F3;color:#0070C0" %)**Response** 1145 1145 |(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=?|(% style="background-color:#f2f2f2; width:199px" %)Show 12V open time.|(% style="background-color:#f2f2f2; width:83px" %)((( ... ... @@ -1164,6 +1164,7 @@ 1164 1164 * Example 5: Downlink Payload: 070301F4 **~-~-->** AT+12VT=500 1165 1165 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 1166 1166 1037 + 1167 1167 == 3.4 Set the all data mode == 1168 1168 1169 1169 ... ... @@ -1186,6 +1186,7 @@ 1186 1186 * Example 1: Downlink Payload: AB 00 ~/~/ AT+ALLDATAMOD=0 1187 1187 * Example 2: Downlink Payload: AB 01 ~/~/ AT+ALLDATAMOD=1 1188 1188 1060 + 1189 1189 == 3.5 Set the splicing payload for uplink == 1190 1190 1191 1191 ... ... @@ -1242,6 +1242,7 @@ 1242 1242 * Example 1: Downlink Payload: AE 01 ~/~/ AT+PAYVER=1 1243 1243 * Example 2: Downlink Payload: AE 05 ~/~/ AT+PAYVER=5 1244 1244 1117 + 1245 1245 = 4. Battery & Power Consumption = 1246 1246 1247 1247 ... ... @@ -1328,6 +1328,7 @@ 1328 1328 * Package Size / pcs : cm 1329 1329 * Weight / pcs : g 1330 1330 1204 + 1331 1331 = 10. Support = 1332 1332 1333 1333