<
From version < 73.1 >
edited by Saxer Lin
on 2023/06/26 15:19
To version < 72.3 >
edited by Xiaoling
on 2023/06/05 18:12
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Saxer
1 +XWiki.Xiaoling
Content
... ... @@ -66,6 +66,7 @@
66 66  * 8500mAh Battery for long term use
67 67  
68 68  
69 +
69 69  == 1.3 Specification ==
70 70  
71 71  
... ... @@ -115,6 +115,7 @@
115 115  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
116 116  
117 117  
119 +
118 118  == 1.4 Connect to SDI-12 Sensor ==
119 119  
120 120  
... ... @@ -150,6 +150,7 @@
150 150  |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode.
151 151  
152 152  
155 +
153 153  == 1.7 Pin Mapping ==
154 154  
155 155  
... ... @@ -399,7 +399,7 @@
399 399  This command can be used to debug all SDI-12 command.
400 400  
401 401  
402 -LoRaWAN Downlink: A8 aa xx xx xx xx bb cc dd
405 +LoRaWAN Downlink: A8 aa xx xx xx xx bb cc
403 403  
404 404  (% style="color:#037691" %)**aa **(%%): total SDI-12 command length
405 405  
... ... @@ -409,11 +409,9 @@
409 409  
410 410  (% style="color:#037691" %)**cc **(%%): 0: don't uplink return to LoRaWAN, 1: Uplink return to LoRaWAN on FPORT=100
411 411  
412 -(% style="color:#037691" %)**dd: **(%%) 0: Do not use aD0! command access, 1: use aD0! command access.
413 413  
416 +(% style="color:blue" %)**Example: **(%%) AT+CFGDEV =0RC0!,1
414 414  
415 -(% style="color:blue" %)**Example1: **(%%) AT+CFGDEV =0RC0!,1
416 -
417 417  (% style="color:#037691" %)**0RC0! **(%%): SDI-12 Command,
418 418  
419 419  (% style="color:#037691" %)**1 **(%%): Delay 1 second.  ( 0: 810 mini-second)
... ... @@ -430,17 +430,6 @@
430 430  [[image:image-20230201092355-17.png||_mstalt="454337" height="426" width="1135"]]
431 431  
432 432  
433 -(% style="color:blue" %)**Example2: **(%%) AT+CFGDEV =0M!,1,1  or  AT+CFGDEV =0C!,1,1
434 -
435 -(% style="color:#037691" %)**0M! **(%%): SDI-12 Command,
436 -
437 -(% style="color:#037691" %)**1 **(%%): Delay 1 second.  ( 0: 810 mini-second)
438 -
439 -(% style="color:#037691" %)**1 **(%%):Use aD0! command access.
440 -
441 -Equal Downlink: 0xA8 03 30  4D 21 01 01 01
442 -
443 -
444 444  === 2.3.3 Convert ASCII to String ===
445 445  
446 446  
... ... @@ -919,6 +919,7 @@
919 919  
920 920  === (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.4 Example 4 ~-~- Connect to TEROS-12 ===
921 921  
912 +
922 922  ==== 2.6.4.1 Reference Manual and Command ====
923 923  
924 924  
... ... @@ -971,6 +971,7 @@
971 971  * If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB.
972 972  
973 973  
965 +
974 974  ==== 2.6.5.2 Hardware Connection to SDI-12-LB ====
975 975  
976 976  
... ... @@ -1063,6 +1063,7 @@
1063 1063  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
1064 1064  
1065 1065  
1058 +
1066 1066  == 3.2 Set Interrupt Mode ==
1067 1067  
1068 1068  
... ... @@ -1095,6 +1095,7 @@
1095 1095  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
1096 1096  
1097 1097  
1091 +
1098 1098  == 3.3 Set the output time ==
1099 1099  
1100 1100  
... ... @@ -1138,10 +1138,8 @@
1138 1138  OK
1139 1139  )))
1140 1140  
1141 -(% style="color:blue" %)**AT Command: AT+12VT **
1135 +(% style="color:blue" %)**AT Command: AT+12VT**
1142 1142  
1143 -(% style="color:blue" %)**(The v1.2 version is enabled for 1 second by default, and the version below v1.2 is disabled by default)**
1144 -
1145 1145  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:443px" %)
1146 1146  |=(% style="width: 156px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 199px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 83px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1147 1147  |(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=?|(% style="background-color:#f2f2f2; width:199px" %)Show 12V open time.|(% style="background-color:#f2f2f2; width:83px" %)(((
... ... @@ -1167,6 +1167,7 @@
1167 1167  * Example 6: Downlink Payload: 07030000  **~-~-->**  AT+12VT=0
1168 1168  
1169 1169  
1162 +
1170 1170  == 3.4 Set the all data mode ==
1171 1171  
1172 1172  
... ... @@ -1190,6 +1190,7 @@
1190 1190  * Example 2: Downlink Payload: AB 01  ~/~/  AT+ALLDATAMOD=1
1191 1191  
1192 1192  
1186 +
1193 1193  == 3.5 Set the splicing payload for uplink ==
1194 1194  
1195 1195  
... ... @@ -1247,6 +1247,7 @@
1247 1247  * Example 2: Downlink Payload: AE 05  ~/~/  AT+PAYVER=5
1248 1248  
1249 1249  
1244 +
1250 1250  = 4. Battery & Power Consumption =
1251 1251  
1252 1252  
... ... @@ -1334,6 +1334,7 @@
1334 1334  * Weight / pcs : g
1335 1335  
1336 1336  
1332 +
1337 1337  = 10. ​Support =
1338 1338  
1339 1339  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0