Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Xiaoling on 2025/04/25 08:58
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Saxer1 +XWiki.Xiaoling - Content
-
... ... @@ -66,6 +66,7 @@ 66 66 * 8500mAh Battery for long term use 67 67 68 68 69 + 69 69 == 1.3 Specification == 70 70 71 71 ... ... @@ -115,6 +115,7 @@ 115 115 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 116 116 117 117 119 + 118 118 == 1.4 Connect to SDI-12 Sensor == 119 119 120 120 ... ... @@ -150,6 +150,7 @@ 150 150 |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode. 151 151 152 152 155 + 153 153 == 1.7 Pin Mapping == 154 154 155 155 ... ... @@ -399,7 +399,7 @@ 399 399 This command can be used to debug all SDI-12 command. 400 400 401 401 402 -LoRaWAN Downlink: A8 aa xx xx xx xx bb cc dd405 +LoRaWAN Downlink: A8 aa xx xx xx xx bb cc 403 403 404 404 (% style="color:#037691" %)**aa **(%%): total SDI-12 command length 405 405 ... ... @@ -409,11 +409,9 @@ 409 409 410 410 (% style="color:#037691" %)**cc **(%%): 0: don't uplink return to LoRaWAN, 1: Uplink return to LoRaWAN on FPORT=100 411 411 412 -(% style="color:#037691" %)**dd: **(%%) 0: Do not use aD0! command access, 1: use aD0! command access. 413 413 416 +(% style="color:blue" %)**Example: **(%%) AT+CFGDEV =0RC0!,1 414 414 415 -(% style="color:blue" %)**Example1: **(%%) AT+CFGDEV =0RC0!,1 416 - 417 417 (% style="color:#037691" %)**0RC0! **(%%): SDI-12 Command, 418 418 419 419 (% style="color:#037691" %)**1 **(%%): Delay 1 second. ( 0: 810 mini-second) ... ... @@ -430,17 +430,6 @@ 430 430 [[image:image-20230201092355-17.png||_mstalt="454337" height="426" width="1135"]] 431 431 432 432 433 -(% style="color:blue" %)**Example2: **(%%) AT+CFGDEV =0M!,1,1 or AT+CFGDEV =0C!,1,1 434 - 435 -(% style="color:#037691" %)**0M! **(%%): SDI-12 Command, 436 - 437 -(% style="color:#037691" %)**1 **(%%): Delay 1 second. ( 0: 810 mini-second) 438 - 439 -(% style="color:#037691" %)**1 **(%%):Use aD0! command access. 440 - 441 -Equal Downlink: 0xA8 03 30 4D 21 01 01 01 442 - 443 - 444 444 === 2.3.3 Convert ASCII to String === 445 445 446 446 ... ... @@ -919,6 +919,7 @@ 919 919 920 920 === (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.4 Example 4 ~-~- Connect to TEROS-12 === 921 921 912 + 922 922 ==== 2.6.4.1 Reference Manual and Command ==== 923 923 924 924 ... ... @@ -971,6 +971,7 @@ 971 971 * If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB. 972 972 973 973 965 + 974 974 ==== 2.6.5.2 Hardware Connection to SDI-12-LB ==== 975 975 976 976 ... ... @@ -1063,6 +1063,7 @@ 1063 1063 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1064 1064 1065 1065 1058 + 1066 1066 == 3.2 Set Interrupt Mode == 1067 1067 1068 1068 ... ... @@ -1095,6 +1095,7 @@ 1095 1095 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1096 1096 1097 1097 1091 + 1098 1098 == 3.3 Set the output time == 1099 1099 1100 1100 ... ... @@ -1138,10 +1138,8 @@ 1138 1138 OK 1139 1139 ))) 1140 1140 1141 -(% style="color:blue" %)**AT Command: AT+12VT 1135 +(% style="color:blue" %)**AT Command: AT+12VT** 1142 1142 1143 -(% style="color:blue" %)**(The v1.2 version is enabled for 1 second by default, and the version below v1.2 is disabled by default)** 1144 - 1145 1145 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:443px" %) 1146 1146 |=(% style="width: 156px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 199px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 83px;background-color:#D9E2F3;color:#0070C0" %)**Response** 1147 1147 |(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=?|(% style="background-color:#f2f2f2; width:199px" %)Show 12V open time.|(% style="background-color:#f2f2f2; width:83px" %)((( ... ... @@ -1167,6 +1167,7 @@ 1167 1167 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 1168 1168 1169 1169 1162 + 1170 1170 == 3.4 Set the all data mode == 1171 1171 1172 1172 ... ... @@ -1190,6 +1190,7 @@ 1190 1190 * Example 2: Downlink Payload: AB 01 ~/~/ AT+ALLDATAMOD=1 1191 1191 1192 1192 1186 + 1193 1193 == 3.5 Set the splicing payload for uplink == 1194 1194 1195 1195 ... ... @@ -1247,6 +1247,7 @@ 1247 1247 * Example 2: Downlink Payload: AE 05 ~/~/ AT+PAYVER=5 1248 1248 1249 1249 1244 + 1250 1250 = 4. Battery & Power Consumption = 1251 1251 1252 1252 ... ... @@ -1334,6 +1334,7 @@ 1334 1334 * Weight / pcs : g 1335 1335 1336 1336 1332 + 1337 1337 = 10. Support = 1338 1338 1339 1339