... ... @@ -1,1 +1,1 @@
1 -XWiki.Saxer
1 +XWiki.Xiaoling
Content
... ... @@ -65,7 +65,6 @@
65 65  * Downlink to change configure
66 66  * 8500mAh Battery for long term use
67 67  
68 -
69 69  == 1.3 Specification ==
70 70  
71 71  
... ... @@ -114,7 +114,6 @@
114 114  * Sleep Mode: 5uA @ 3.3v
115 115  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
116 116  
117 -
118 118  == 1.4 Connect to SDI-12 Sensor ==
119 119  
120 120  
... ... @@ -149,7 +149,6 @@
149 149  )))
150 150  |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode.
151 151  
152 -
153 153  == 1.7 Pin Mapping ==
154 154  
155 155  
... ... @@ -399,7 +399,7 @@
399 399  This command can be used to debug all SDI-12 command.
400 400  
401 401  
402 -LoRaWAN Downlink: A8 aa xx xx xx xx bb cc dd
399 +LoRaWAN Downlink: A8 aa xx xx xx xx bb cc
403 403  
404 404  (% style="color:#037691" %)**aa **(%%): total SDI-12 command length
405 405  
... ... @@ -409,11 +409,9 @@
409 409  
410 410  (% style="color:#037691" %)**cc **(%%): 0: don't uplink return to LoRaWAN, 1: Uplink return to LoRaWAN on FPORT=100
411 411  
412 -(% style="color:#037691" %)**dd: **(%%) 0: Do not use aD0! command access, 1: use aD0! command access.
413 413  
410 +(% style="color:blue" %)**Example: **(%%) AT+CFGDEV =0RC0!,1
414 414  
415 -(% style="color:blue" %)**Example1: **(%%) AT+CFGDEV =0RC0!,1
416 -
417 417  (% style="color:#037691" %)**0RC0! **(%%): SDI-12 Command,
418 418  
419 419  (% style="color:#037691" %)**1 **(%%): Delay 1 second.  ( 0: 810 mini-second)
... ... @@ -430,17 +430,6 @@
430 430  [[image:image-20230201092355-17.png||_mstalt="454337" height="426" width="1135"]]
431 431  
432 432  
433 -(% style="color:blue" %)**Example2: **(%%) AT+CFGDEV =0M!,1,1  or  AT+CFGDEV =0C!,1,1
434 -
435 -(% style="color:#037691" %)**0M! **(%%): SDI-12 Command,
436 -
437 -(% style="color:#037691" %)**1 **(%%): Delay 1 second.  ( 0: 810 mini-second)
438 -
439 -(% style="color:#037691" %)**1 **(%%):Use aD0! command access.
440 -
441 -Equal Downlink: 0xA8 03 30  4D 21 01 01 01
442 -
443 -
444 444  === 2.3.3 Convert ASCII to String ===
445 445  
446 446  
... ... @@ -900,13 +900,11 @@
900 900  
901 901  ==== 2.6.3.2 Hardware Connection to SDI-12-LB ====
902 902  
903 -
904 904  [[image:image-20230603121643-8.png||height="442" width="656"]]
905 905  
906 906  
907 907  ==== 2.6.3.3 Commands set in SDI-12-LB and uplink payload ====
908 908  
909 -
910 910  [[image:image-20230603121721-9.png]]
911 911  
912 912  [[image:image-20230603121752-10.png]]
... ... @@ -919,11 +919,10 @@
919 919  
920 920  === (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.4 Example 4 ~-~- Connect to TEROS-12 ===
921 921  
904 +
922 922  ==== 2.6.4.1 Reference Manual and Command ====
923 923  
924 -
925 925  * [[TEROS-12 Product Page>>https://www.metergroup.com/en/meter-environment/products/teros-12-soil-moisture-sensor]]
926 -
927 927  * Commands to be used in PC and output.
928 928  
929 929  1.check device address
... ... @@ -941,7 +941,6 @@
941 941  
942 942  ==== 2.6.4.2 Hardware Connection to SDI-12-LB ====
943 943  
944 -
945 945  [[image:image-20230603122212-15.png||height="502" width="667"]]
946 946  
947 947  
... ... @@ -951,45 +951,40 @@
951 951  
952 952  [[image:image-20230603122109-13.png||height="469" width="762"]]
953 953  
934 +Data in TTN:
954 954  
955 -**Data in TTN:**
956 -
957 957  [[image:image-20230603122139-14.png||height="148" width="1128"]]
958 958  
959 959  
939 +
960 960  === (% id="cke_bm_1489640S" style="display:none" %) (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.5 Example 5 ~-~- Connect to SIL-400/TEROS-12 & Hygrovue10 ===
961 961  
962 962  ==== 2.6.5.1 Important Notice! ====
963 963  
964 -
965 965  * The product page and reference command see above example 2,3,4
966 -
967 967  * All of these SDI-12 sensors use the same address (address 0) by default. So we need to change their address to different address, by using **aAb!** command. See above example.
968 -
969 969  * The sensor needs to be powered to a steady statue. So the 12VT time need to be set to the maximum stable time for the sensors. in this example, it is 13 seconds.
970 -
971 971  * If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB.
972 972  
973 -
974 974  ==== 2.6.5.2 Hardware Connection to SDI-12-LB ====
975 975  
976 -
977 977  [[image:image-20230603122508-17.png||height="526" width="742"]]
978 978  
979 979  
980 980  ==== 2.6.5.3 Commands set in SDI-12-LB and uplink payload ====
981 981  
982 -
983 983  [[image:image-20230603122549-18.png]]
984 984  
985 985  [[image:image-20230603122623-19.png||height="483" width="1121"]]
986 986  
960 +Data in TTN:
987 987  
988 -**Data in TTN:**
989 -
990 990  [[image:image-20230603122719-20.png||height="151" width="1179"]]
991 991  
992 992  
965 +
966 +
967 +
993 993  == 2.7 Frequency Plans ==
994 994  
995 995  
... ... @@ -1062,7 +1062,6 @@
1062 1062  * Example 1: Downlink Payload: 0100001E  ~/~/ Set Transmit Interval (TDC) = 30 seconds
1063 1063  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
1064 1064  
1065 -
1066 1066  == 3.2 Set Interrupt Mode ==
1067 1067  
1068 1068  
... ... @@ -1094,7 +1094,6 @@
1094 1094  * Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
1095 1095  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
1096 1096  
1097 -
1098 1098  == 3.3 Set the output time ==
1099 1099  
1100 1100  
... ... @@ -1138,10 +1138,8 @@
1138 1138  OK
1139 1139  )))
1140 1140  
1141 -(% style="color:blue" %)**AT Command: AT+12VT **
1114 +(% style="color:blue" %)**AT Command: AT+12VT**
1142 1142  
1143 -(% style="color:blue" %)**(The v1.2 version is enabled for 1 second by default, and the version below v1.2 is disabled by default)**
1144 -
1145 1145  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:443px" %)
1146 1146  |=(% style="width: 156px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 199px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 83px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1147 1147  |(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=?|(% style="background-color:#f2f2f2; width:199px" %)Show 12V open time.|(% style="background-color:#f2f2f2; width:83px" %)(((
... ... @@ -1166,7 +1166,6 @@
1166 1166  * Example 5: Downlink Payload: 070301F4  **~-~-->**  AT+12VT=500
1167 1167  * Example 6: Downlink Payload: 07030000  **~-~-->**  AT+12VT=0
1168 1168  
1169 -
1170 1170  == 3.4 Set the all data mode ==
1171 1171  
1172 1172  
... ... @@ -1189,7 +1189,6 @@
1189 1189  * Example 1: Downlink Payload: AB 00  ~/~/  AT+ALLDATAMOD=0
1190 1190  * Example 2: Downlink Payload: AB 01  ~/~/  AT+ALLDATAMOD=1
1191 1191  
1192 -
1193 1193  == 3.5 Set the splicing payload for uplink ==
1194 1194  
1195 1195  
... ... @@ -1246,7 +1246,6 @@
1246 1246  * Example 1: Downlink Payload: AE 01  ~/~/  AT+PAYVER=1
1247 1247  * Example 2: Downlink Payload: AE 05  ~/~/  AT+PAYVER=5
1248 1248  
1249 -
1250 1250  = 4. Battery & Power Consumption =
1251 1251  
1252 1252  
... ... @@ -1333,7 +1333,6 @@
1333 1333  * Package Size / pcs : cm
1334 1334  * Weight / pcs : g
1335 1335  
1336 -
1337 1337  = 10. ​Support =
1338 1338  
1339 1339  