From version < 73.1 >
edited by Saxer Lin
on 2023/06/26 15:19
To version < 70.1 >
edited by Edwin Chen
on 2023/06/03 12:30
>
Change comment: Uploaded new attachment "image-20230603122719-20.png", version {1}

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Saxer
1 +XWiki.Edwin
Content
... ... @@ -399,7 +399,7 @@
399 399  This command can be used to debug all SDI-12 command.
400 400  
401 401  
402 -LoRaWAN Downlink: A8 aa xx xx xx xx bb cc dd
402 +LoRaWAN Downlink: A8 aa xx xx xx xx bb cc
403 403  
404 404  (% style="color:#037691" %)**aa **(%%): total SDI-12 command length
405 405  
... ... @@ -409,11 +409,9 @@
409 409  
410 410  (% style="color:#037691" %)**cc **(%%): 0: don't uplink return to LoRaWAN, 1: Uplink return to LoRaWAN on FPORT=100
411 411  
412 -(% style="color:#037691" %)**dd: **(%%) 0: Do not use aD0! command access, 1: use aD0! command access.
413 413  
413 +(% style="color:blue" %)**Example: **(%%) AT+CFGDEV =0RC0!,1
414 414  
415 -(% style="color:blue" %)**Example1: **(%%) AT+CFGDEV =0RC0!,1
416 -
417 417  (% style="color:#037691" %)**0RC0! **(%%): SDI-12 Command,
418 418  
419 419  (% style="color:#037691" %)**1 **(%%): Delay 1 second.  ( 0: 810 mini-second)
... ... @@ -430,17 +430,6 @@
430 430  [[image:image-20230201092355-17.png||_mstalt="454337" height="426" width="1135"]]
431 431  
432 432  
433 -(% style="color:blue" %)**Example2: **(%%) AT+CFGDEV =0M!,1,1  or  AT+CFGDEV =0C!,1,1
434 -
435 -(% style="color:#037691" %)**0M! **(%%): SDI-12 Command,
436 -
437 -(% style="color:#037691" %)**1 **(%%): Delay 1 second.  ( 0: 810 mini-second)
438 -
439 -(% style="color:#037691" %)**1 **(%%):Use aD0! command access.
440 -
441 -Equal Downlink: 0xA8 03 30  4D 21 01 01 01
442 -
443 -
444 444  === 2.3.3 Convert ASCII to String ===
445 445  
446 446  
... ... @@ -835,24 +835,22 @@
835 835  Partial cut, the cut sensor address and the first two parameters:(% style="color:#037691" %)**AT+DATACUTx=25,2,1~~12, cut out the character field ” 4+30.8+22.84”**.
836 836  
837 837  
838 -=== 2.6.2 Example 2 ~-~- Connect to Hygrovue10 ===
825 +=== 2.6.2 Example ~-~- Connect to Hygrovue10 ===
839 839  
840 840  ==== 2.6.2.1 Reference Manual and Command ====
841 841  
842 -
843 843  * [[Hygrovue10 Product Page>>https://www.campbellsci.com/hygrovue10]]
844 -
845 845  * Commands to be used in PC and output.
846 846  
847 -~1. check device address
832 +1.check device address
848 848  
849 -2. change device address
834 +2.change device address
850 850  
851 -3. check device ID
836 +3.check device ID
852 852  
853 -4. start measure
838 +4.start measure
854 854  
855 -5. Get Meausre result
840 +5.Get Meausre result
856 856  
857 857  [[image:image-20230603120209-2.png||height="281" width="267"]]
858 858  
... ... @@ -859,137 +859,22 @@
859 859  
860 860  ==== 2.6.2.2 Hardware Connection to SDI-12-LB ====
861 861  
862 -
863 863  [[image:image-20230603120515-3.png]]
864 864  
865 865  
866 866  ==== 2.6.2.3 Commands set in SDI-12-LB and uplink payload ====
867 867  
868 -
869 869  [[image:image-20230603120648-4.png]]
870 870  
871 871  [[image:image-20230603120726-5.png]]
872 872  
856 +Data in TTN:
873 873  
874 -**Data in TTN:**
875 -
876 876  [[image:image-20230603120859-6.png||height="118" width="1285"]]
877 877  
878 878  
879 -=== (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.3 Example 3 ~-~- Connect to SIL-400 ===
880 880  
881 -==== 2.6.3.1 Reference Manual and Command ====
882 882  
883 -
884 -* [[SIL-400 Product Page>>https://www.apogeeinstruments.com/sil-411-commercial-grade-sdi-12-digital-output-standard-field-of-view-infrared-radiometer-sensor/]]
885 -
886 -* Commands to be used in PC and output.
887 -
888 -~1. check device address
889 -
890 -2. change device address
891 -
892 -3. check device ID
893 -
894 -4. start measure
895 -
896 -5. Get Meausre result
897 -
898 -[[image:image-20230603121606-7.png||height="242" width="307"]]
899 -
900 -
901 -==== 2.6.3.2 Hardware Connection to SDI-12-LB ====
902 -
903 -
904 -[[image:image-20230603121643-8.png||height="442" width="656"]]
905 -
906 -
907 -==== 2.6.3.3 Commands set in SDI-12-LB and uplink payload ====
908 -
909 -
910 -[[image:image-20230603121721-9.png]]
911 -
912 -[[image:image-20230603121752-10.png]]
913 -
914 -Data in TTN:
915 -
916 -[[image:image-20230603121826-11.png||height="155" width="1104"]]
917 -
918 -
919 -
920 -=== (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.4 Example 4 ~-~- Connect to TEROS-12 ===
921 -
922 -==== 2.6.4.1 Reference Manual and Command ====
923 -
924 -
925 -* [[TEROS-12 Product Page>>https://www.metergroup.com/en/meter-environment/products/teros-12-soil-moisture-sensor]]
926 -
927 -* Commands to be used in PC and output.
928 -
929 -1.check device address
930 -
931 -2.change device address
932 -
933 -3.check device ID
934 -
935 -4.start measure
936 -
937 -5.Get Meausre result
938 -
939 -[[image:image-20230603122248-16.png||height="196" width="198"]]
940 -
941 -
942 -==== 2.6.4.2 Hardware Connection to SDI-12-LB ====
943 -
944 -
945 -[[image:image-20230603122212-15.png||height="502" width="667"]]
946 -
947 -
948 -==== 2.6.4.3 Commands set in SDI-12-LB and uplink payload ====
949 -
950 -[[image:image-20230603122040-12.png]]
951 -
952 -[[image:image-20230603122109-13.png||height="469" width="762"]]
953 -
954 -
955 -**Data in TTN:**
956 -
957 -[[image:image-20230603122139-14.png||height="148" width="1128"]]
958 -
959 -
960 -=== (% id="cke_bm_1489640S" style="display:none" %) (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.5 Example 5 ~-~- Connect to SIL-400/TEROS-12 & Hygrovue10 ===
961 -
962 -==== 2.6.5.1 Important Notice! ====
963 -
964 -
965 -* The product page and reference command see above example 2,3,4
966 -
967 -* All of these SDI-12 sensors use the same address (address 0) by default. So we need to change their address to different address, by using **aAb!** command. See above example.
968 -
969 -* The sensor needs to be powered to a steady statue. So the 12VT time need to be set to the maximum stable time for the sensors. in this example, it is 13 seconds.
970 -
971 -* If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB.
972 -
973 -
974 -==== 2.6.5.2 Hardware Connection to SDI-12-LB ====
975 -
976 -
977 -[[image:image-20230603122508-17.png||height="526" width="742"]]
978 -
979 -
980 -==== 2.6.5.3 Commands set in SDI-12-LB and uplink payload ====
981 -
982 -
983 -[[image:image-20230603122549-18.png]]
984 -
985 -[[image:image-20230603122623-19.png||height="483" width="1121"]]
986 -
987 -
988 -**Data in TTN:**
989 -
990 -[[image:image-20230603122719-20.png||height="151" width="1179"]]
991 -
992 -
993 993  == 2.7 Frequency Plans ==
994 994  
995 995  
... ... @@ -1138,10 +1138,8 @@
1138 1138  OK
1139 1139  )))
1140 1140  
1141 -(% style="color:blue" %)**AT Command: AT+12VT **
1011 +(% style="color:blue" %)**AT Command: AT+12VT**
1142 1142  
1143 -(% style="color:blue" %)**(The v1.2 version is enabled for 1 second by default, and the version below v1.2 is disabled by default)**
1144 -
1145 1145  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:443px" %)
1146 1146  |=(% style="width: 156px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 199px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 83px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1147 1147  |(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=?|(% style="background-color:#f2f2f2; width:199px" %)Show 12V open time.|(% style="background-color:#f2f2f2; width:83px" %)(((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved