<
From version < 72.3 >
edited by Xiaoling
on 2023/06/05 18:12
To version < 71.1 >
edited by Edwin Chen
on 2023/06/03 12:38
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Edwin
Content
... ... @@ -65,8 +65,6 @@
65 65  * Downlink to change configure
66 66  * 8500mAh Battery for long term use
67 67  
68 -
69 -
70 70  == 1.3 Specification ==
71 71  
72 72  
... ... @@ -115,8 +115,6 @@
115 115  * Sleep Mode: 5uA @ 3.3v
116 116  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
117 117  
118 -
119 -
120 120  == 1.4 Connect to SDI-12 Sensor ==
121 121  
122 122  
... ... @@ -151,8 +151,6 @@
151 151  )))
152 152  |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode.
153 153  
154 -
155 -
156 156  == 1.7 Pin Mapping ==
157 157  
158 158  
... ... @@ -829,20 +829,18 @@
829 829  
830 830  ==== 2.6.2.1 Reference Manual and Command ====
831 831  
832 -
833 833  * [[Hygrovue10 Product Page>>https://www.campbellsci.com/hygrovue10]]
834 -
835 835  * Commands to be used in PC and output.
836 836  
837 -~1. check device address
829 +1.check device address
838 838  
839 -2. change device address
831 +2.change device address
840 840  
841 -3. check device ID
833 +3.check device ID
842 842  
843 -4. start measure
835 +4.start measure
844 844  
845 -5. Get Meausre result
837 +5.Get Meausre result
846 846  
847 847  [[image:image-20230603120209-2.png||height="281" width="267"]]
848 848  
... ... @@ -849,20 +849,17 @@
849 849  
850 850  ==== 2.6.2.2 Hardware Connection to SDI-12-LB ====
851 851  
852 -
853 853  [[image:image-20230603120515-3.png]]
854 854  
855 855  
856 856  ==== 2.6.2.3 Commands set in SDI-12-LB and uplink payload ====
857 857  
858 -
859 859  [[image:image-20230603120648-4.png]]
860 860  
861 861  [[image:image-20230603120726-5.png]]
862 862  
853 +Data in TTN:
863 863  
864 -**Data in TTN:**
865 -
866 866  [[image:image-20230603120859-6.png||height="118" width="1285"]]
867 867  
868 868  
... ... @@ -870,20 +870,18 @@
870 870  
871 871  ==== 2.6.3.1 Reference Manual and Command ====
872 872  
873 -
874 874  * [[SIL-400 Product Page>>https://www.apogeeinstruments.com/sil-411-commercial-grade-sdi-12-digital-output-standard-field-of-view-infrared-radiometer-sensor/]]
875 -
876 876  * Commands to be used in PC and output.
877 877  
878 -~1. check device address
865 +1.check device address
879 879  
880 -2. change device address
867 +2.change device address
881 881  
882 -3. check device ID
869 +3.check device ID
883 883  
884 -4. start measure
871 +4.start measure
885 885  
886 -5. Get Meausre result
873 +5.Get Meausre result
887 887  
888 888  [[image:image-20230603121606-7.png||height="242" width="307"]]
889 889  
... ... @@ -890,13 +890,11 @@
890 890  
891 891  ==== 2.6.3.2 Hardware Connection to SDI-12-LB ====
892 892  
893 -
894 894  [[image:image-20230603121643-8.png||height="442" width="656"]]
895 895  
896 896  
897 897  ==== 2.6.3.3 Commands set in SDI-12-LB and uplink payload ====
898 898  
899 -
900 900  [[image:image-20230603121721-9.png]]
901 901  
902 902  [[image:image-20230603121752-10.png]]
... ... @@ -912,9 +912,7 @@
912 912  
913 913  ==== 2.6.4.1 Reference Manual and Command ====
914 914  
915 -
916 916  * [[TEROS-12 Product Page>>https://www.metergroup.com/en/meter-environment/products/teros-12-soil-moisture-sensor]]
917 -
918 918  * Commands to be used in PC and output.
919 919  
920 920  1.check device address
... ... @@ -932,7 +932,6 @@
932 932  
933 933  ==== 2.6.4.2 Hardware Connection to SDI-12-LB ====
934 934  
935 -
936 936  [[image:image-20230603122212-15.png||height="502" width="667"]]
937 937  
938 938  
... ... @@ -942,46 +942,42 @@
942 942  
943 943  [[image:image-20230603122109-13.png||height="469" width="762"]]
944 944  
927 +Data in TTN:
945 945  
946 -**Data in TTN:**
947 -
948 948  [[image:image-20230603122139-14.png||height="148" width="1128"]]
949 949  
950 950  
951 -=== (% id="cke_bm_1489640S" style="display:none" %) (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.5 Example 5 ~-~- Connect to SIL-400/TEROS-12 & Hygrovue10 ===
952 952  
953 -==== 2.6.5.1 Important Notice! ====
933 +=== (% id="cke_bm_1489640S" style="display: none; display: none" %) (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.5 Example 5 ~-~- Connect to SIL-400/TEROS-12 & Hygrovue10 ===
954 954  
935 +==== 2.6.3.1 Important Notice! ====
955 955  
956 956  * The product page and reference command see above example 2,3,4
957 -
958 958  * All of these SDI-12 sensors use the same address (address 0) by default. So we need to change their address to different address, by using **aAb!** command. See above example.
959 -
960 960  * The sensor needs to be powered to a steady statue. So the 12VT time need to be set to the maximum stable time for the sensors. in this example, it is 13 seconds.
961 -
962 962  * If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB.
963 963  
964 964  
965 965  
966 -==== 2.6.5.2 Hardware Connection to SDI-12-LB ====
944 +==== 2.6.3.2 Hardware Connection to SDI-12-LB ====
967 967  
968 -
969 969  [[image:image-20230603122508-17.png||height="526" width="742"]]
970 970  
971 971  
972 -==== 2.6.5.3 Commands set in SDI-12-LB and uplink payload ====
949 +==== 2.6.3.3 Commands set in SDI-12-LB and uplink payload ====
973 973  
974 -
975 975  [[image:image-20230603122549-18.png]]
976 976  
977 977  [[image:image-20230603122623-19.png||height="483" width="1121"]]
978 978  
955 +Data in TTN:
979 979  
980 -**Data in TTN:**
981 -
982 982  [[image:image-20230603122719-20.png||height="151" width="1179"]]
983 983  
984 984  
960 +
961 +
962 +
985 985  == 2.7 Frequency Plans ==
986 986  
987 987  
... ... @@ -1054,8 +1054,6 @@
1054 1054  * Example 1: Downlink Payload: 0100001E  ~/~/ Set Transmit Interval (TDC) = 30 seconds
1055 1055  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
1056 1056  
1057 -
1058 -
1059 1059  == 3.2 Set Interrupt Mode ==
1060 1060  
1061 1061  
... ... @@ -1087,8 +1087,6 @@
1087 1087  * Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
1088 1088  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
1089 1089  
1090 -
1091 -
1092 1092  == 3.3 Set the output time ==
1093 1093  
1094 1094  
... ... @@ -1158,8 +1158,6 @@
1158 1158  * Example 5: Downlink Payload: 070301F4  **~-~-->**  AT+12VT=500
1159 1159  * Example 6: Downlink Payload: 07030000  **~-~-->**  AT+12VT=0
1160 1160  
1161 -
1162 -
1163 1163  == 3.4 Set the all data mode ==
1164 1164  
1165 1165  
... ... @@ -1182,8 +1182,6 @@
1182 1182  * Example 1: Downlink Payload: AB 00  ~/~/  AT+ALLDATAMOD=0
1183 1183  * Example 2: Downlink Payload: AB 01  ~/~/  AT+ALLDATAMOD=1
1184 1184  
1185 -
1186 -
1187 1187  == 3.5 Set the splicing payload for uplink ==
1188 1188  
1189 1189  
... ... @@ -1240,8 +1240,6 @@
1240 1240  * Example 1: Downlink Payload: AE 01  ~/~/  AT+PAYVER=1
1241 1241  * Example 2: Downlink Payload: AE 05  ~/~/  AT+PAYVER=5
1242 1242  
1243 -
1244 -
1245 1245  = 4. Battery & Power Consumption =
1246 1246  
1247 1247  
... ... @@ -1328,8 +1328,6 @@
1328 1328  * Package Size / pcs : cm
1329 1329  * Weight / pcs : g
1330 1330  
1331 -
1332 -
1333 1333  = 10. ​Support =
1334 1334  
1335 1335  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0