Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Mengting Qiu on 2025/07/03 15:42
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 8 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Saxer - Content
-
... ... @@ -116,7 +116,6 @@ 116 116 == 1.4 Connect to SDI-12 Sensor == 117 117 118 118 119 - 120 120 [[image:1675212538524-889.png||_mstalt="298272"]] 121 121 122 122 ... ... @@ -201,7 +201,6 @@ 201 201 202 202 Each SDI-12-LB is shipped with a sticker with the default device EUI as below: 203 203 204 - 205 205 [[image:image-20230426084456-1.png||height="241" width="519"]] 206 206 207 207 ... ... @@ -396,7 +396,7 @@ 396 396 This command can be used to debug all SDI-12 command. 397 397 398 398 399 -LoRaWAN Downlink: A8 aa xx xx xx xx bb cc 397 +LoRaWAN Downlink: A8 aa xx xx xx xx bb cc dd 400 400 401 401 (% style="color:#037691" %)**aa **(%%): total SDI-12 command length 402 402 ... ... @@ -406,9 +406,11 @@ 406 406 407 407 (% style="color:#037691" %)**cc **(%%): 0: don't uplink return to LoRaWAN, 1: Uplink return to LoRaWAN on FPORT=100 408 408 407 +(% style="color:#037691" %)**dd: **(%%) 0: Do not use aD0! command access, 1: use aD0! command access. 409 409 410 -(% style="color:blue" %)**Example: **(%%) AT+CFGDEV =0RC0!,1 411 411 410 +(% style="color:blue" %)**Example1: **(%%) AT+CFGDEV =0RC0!,1 411 + 412 412 (% style="color:#037691" %)**0RC0! **(%%): SDI-12 Command, 413 413 414 414 (% style="color:#037691" %)**1 **(%%): Delay 1 second. ( 0: 810 mini-second) ... ... @@ -425,6 +425,17 @@ 425 425 [[image:image-20230201092355-17.png||_mstalt="454337" height="426" width="1135"]] 426 426 427 427 428 +(% style="color:blue" %)**Example2: **(%%) AT+CFGDEV =0M!,1,1 or AT+CFGDEV =0C!,1,1 429 + 430 +(% style="color:#037691" %)**0M! **(%%): SDI-12 Command, 431 + 432 +(% style="color:#037691" %)**1 **(%%): Delay 1 second. ( 0: 810 mini-second) 433 + 434 +(% style="color:#037691" %)**1 **(%%):Use aD0! command access. 435 + 436 +Equal Downlink: 0xA8 03 30 4D 21 01 01 01 437 + 438 + 428 428 === 2.3.3 Convert ASCII to String === 429 429 430 430 ... ... @@ -630,33 +630,33 @@ 630 630 631 631 (% style="color:#037691" %)**Frequency Band**: 632 632 633 - *0x01: EU868644 +0x01: EU868 634 634 635 - *0x02: US915646 +0x02: US915 636 636 637 - *0x03: IN865648 +0x03: IN865 638 638 639 - *0x04: AU915650 +0x04: AU915 640 640 641 - *0x05: KZ865652 +0x05: KZ865 642 642 643 - *0x06: RU864654 +0x06: RU864 644 644 645 - *0x07: AS923656 +0x07: AS923 646 646 647 - *0x08: AS923-1658 +0x08: AS923-1 648 648 649 - *0x09: AS923-2660 +0x09: AS923-2 650 650 651 - *0x0a: AS923-3662 +0x0a: AS923-3 652 652 653 - *0x0b: CN470664 +0x0b: CN470 654 654 655 - *0x0c: EU433666 +0x0c: EU433 656 656 657 - *0x0d: KR920668 +0x0d: KR920 658 658 659 - *0x0e: MA869670 +0x0e: MA869 660 660 661 661 662 662 (% style="color:#037691" %)**Sub-Band**: ... ... @@ -687,9 +687,9 @@ 687 687 * Periodically Uplink: FPORT=2 688 688 689 689 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %) 690 -|=(% style="width: 90px;background-color:#D9E2F3" %)((( 701 +|=(% style="width: 90px;background-color:#D9E2F3;color:#0070C0" %)((( 691 691 **Size(bytes)** 692 -)))|=(% style="width: 80px;background-color:#D9E2F3" %)**2**|=(% style="width: 90px;background-color:#D9E2F3" %)**1**|=(% style="width: 240px;background-color:#D9E2F3" %)**Length depends on the return from the commands** 703 +)))|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 90px;background-color:#D9E2F3;color:#0070C0" %)**1**|=(% style="width: 240px;background-color:#D9E2F3;color:#0070C0" %)**Length depends on the return from the commands** 693 693 |(% style="width:93px" %)**Value**|(% style="width:83px" %)((( 694 694 Battery(mV) 695 695 & ... ... @@ -884,14 +884,16 @@ 884 884 885 885 ==== 2.6.3.2 Hardware Connection to SDI-12-LB ==== 886 886 898 + 887 887 [[image:image-20230603121643-8.png||height="442" width="656"]] 888 888 889 889 890 890 ==== 2.6.3.3 Commands set in SDI-12-LB and uplink payload ==== 891 891 904 + 892 892 [[image:image-20230603121721-9.png]] 893 893 894 -[[image:image-20230603 121752-10.png]]907 +[[image:image-20230628090323-1.png||height="414" width="694"]] 895 895 896 896 Data in TTN: 897 897 ... ... @@ -901,10 +901,11 @@ 901 901 902 902 === (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.4 Example 4 ~-~- Connect to TEROS-12 === 903 903 904 - 905 905 ==== 2.6.4.1 Reference Manual and Command ==== 906 906 919 + 907 907 * [[TEROS-12 Product Page>>https://www.metergroup.com/en/meter-environment/products/teros-12-soil-moisture-sensor]] 921 + 908 908 * Commands to be used in PC and output. 909 909 910 910 1.check device address ... ... @@ -922,49 +922,95 @@ 922 922 923 923 ==== 2.6.4.2 Hardware Connection to SDI-12-LB ==== 924 924 939 + 925 925 [[image:image-20230603122212-15.png||height="502" width="667"]] 926 926 927 927 928 928 ==== 2.6.4.3 Commands set in SDI-12-LB and uplink payload ==== 929 929 945 + 930 930 [[image:image-20230603122040-12.png]] 931 931 932 932 [[image:image-20230603122109-13.png||height="469" width="762"]] 933 933 934 -Data in TTN: 935 935 951 +**Data in TTN:** 952 + 936 936 [[image:image-20230603122139-14.png||height="148" width="1128"]] 937 937 938 938 939 - 940 940 === (% id="cke_bm_1489640S" style="display:none" %) (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.5 Example 5 ~-~- Connect to SIL-400/TEROS-12 & Hygrovue10 === 941 941 942 942 ==== 2.6.5.1 Important Notice! ==== 943 943 960 + 944 944 * The product page and reference command see above example 2,3,4 962 + 945 945 * All of these SDI-12 sensors use the same address (address 0) by default. So we need to change their address to different address, by using **aAb!** command. See above example. 964 + 946 946 * The sensor needs to be powered to a steady statue. So the 12VT time need to be set to the maximum stable time for the sensors. in this example, it is 13 seconds. 966 + 947 947 * If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB. 948 948 949 949 ==== 2.6.5.2 Hardware Connection to SDI-12-LB ==== 950 950 971 + 951 951 [[image:image-20230603122508-17.png||height="526" width="742"]] 952 952 953 953 954 954 ==== 2.6.5.3 Commands set in SDI-12-LB and uplink payload ==== 955 955 977 + 956 956 [[image:image-20230603122549-18.png]] 957 957 958 958 [[image:image-20230603122623-19.png||height="483" width="1121"]] 959 959 960 -Data in TTN: 961 961 983 +**Data in TTN:** 984 + 962 962 [[image:image-20230603122719-20.png||height="151" width="1179"]] 963 963 964 964 988 +=== (% id="cke_bm_4783S" style="display:none" %) (%%)2.6.6 Example 6 ~-~- Connect to ENTELECHY-EP_SDI-12 === 965 965 990 +==== 2.6.4.1 Reference Manual and Command ==== 966 966 967 967 993 +* [[https:~~/~~/enviroprosoilprobes.com/wp-content/uploads/2019/11/ENTELECHY-EP_SDI-12-Commands.pdf>>url:https://enviroprosoilprobes.com/wp-content/uploads/2019/11/ENTELECHY-EP_SDI-12-Commands.pdf]] 994 + 995 +* Commands to be used in PC and output. 996 + 997 +1.check device address 998 + 999 +2.change device address 1000 + 1001 +3.check device ID 1002 + 1003 +4.start measure 1004 + 1005 +5.Get Meausre result 1006 + 1007 + 1008 +[[image:image-20230627174559-3.png]] 1009 + 1010 +==== 2.6.4.2 Hardware Connection to SDI-12-LB ==== 1011 + 1012 +[[image:image-20230627174446-2.png]] 1013 + 1014 + 1015 + 1016 +==== 2.6.4.3 Commands set in SDI-12-LB and uplink payload ==== 1017 + 1018 + 1019 +[[image:image-20230627175513-4.png||height="596" width="576"]] 1020 + 1021 +[[image:image-20230627175736-5.png||height="429" width="693"]] 1022 + 1023 + 1024 +**Data in TTN:** 1025 + 1026 +[[image:image-20230627180303-6.png||height="292" width="1171"]] 1027 + 968 968 == 2.7 Frequency Plans == 969 969 970 970 ... ... @@ -1111,8 +1111,10 @@ 1111 1111 OK 1112 1112 ))) 1113 1113 1114 -(% style="color:blue" %)**AT Command: AT+12VT** 1174 +(% style="color:blue" %)**AT Command: AT+12VT ** 1115 1115 1176 +(% style="color:blue" %)**(The v1.2 version is enabled for 1 second by default, and the version below v1.2 is disabled by default)** 1177 + 1116 1116 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:443px" %) 1117 1117 |=(% style="width: 156px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 199px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 83px;background-color:#D9E2F3;color:#0070C0" %)**Response** 1118 1118 |(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=?|(% style="background-color:#f2f2f2; width:199px" %)Show 12V open time.|(% style="background-color:#f2f2f2; width:83px" %)((( ... ... @@ -1272,7 +1272,7 @@ 1272 1272 ))) 1273 1273 1274 1274 ((( 1275 -XXX: The default frequency band 1337 +(% style="color:blue" %)**XXX**(%%): The default frequency band 1276 1276 ))) 1277 1277 1278 1278 (((
- image-20230627164957-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +835.0 KB - Content
- image-20230627165744-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +4.6 KB - Content
- image-20230627174446-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +835.0 KB - Content
- image-20230627174559-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +4.6 KB - Content
- image-20230627175513-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.0 KB - Content
- image-20230627175736-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.4 KB - Content
- image-20230627180303-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +65.1 KB - Content
- image-20230628090323-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Saxer - Size
-
... ... @@ -1,0 +1,1 @@ 1 +137.2 KB - Content