<
From version < 72.2 >
edited by Xiaoling
on 2023/06/05 18:07
To version < 72.3 >
edited by Xiaoling
on 2023/06/05 18:12
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -65,6 +65,8 @@
65 65  * Downlink to change configure
66 66  * 8500mAh Battery for long term use
67 67  
68 +
69 +
68 68  == 1.3 Specification ==
69 69  
70 70  
... ... @@ -113,6 +113,8 @@
113 113  * Sleep Mode: 5uA @ 3.3v
114 114  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
115 115  
118 +
119 +
116 116  == 1.4 Connect to SDI-12 Sensor ==
117 117  
118 118  
... ... @@ -147,6 +147,8 @@
147 147  )))
148 148  |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode.
149 149  
154 +
155 +
150 150  == 1.7 Pin Mapping ==
151 151  
152 152  
... ... @@ -884,11 +884,13 @@
884 884  
885 885  ==== 2.6.3.2 Hardware Connection to SDI-12-LB ====
886 886  
893 +
887 887  [[image:image-20230603121643-8.png||height="442" width="656"]]
888 888  
889 889  
890 890  ==== 2.6.3.3 Commands set in SDI-12-LB and uplink payload ====
891 891  
899 +
892 892  [[image:image-20230603121721-9.png]]
893 893  
894 894  [[image:image-20230603121752-10.png]]
... ... @@ -904,7 +904,9 @@
904 904  
905 905  ==== 2.6.4.1 Reference Manual and Command ====
906 906  
915 +
907 907  * [[TEROS-12 Product Page>>https://www.metergroup.com/en/meter-environment/products/teros-12-soil-moisture-sensor]]
917 +
908 908  * Commands to be used in PC and output.
909 909  
910 910  1.check device address
... ... @@ -922,6 +922,7 @@
922 922  
923 923  ==== 2.6.4.2 Hardware Connection to SDI-12-LB ====
924 924  
935 +
925 925  [[image:image-20230603122212-15.png||height="502" width="667"]]
926 926  
927 927  
... ... @@ -931,40 +931,46 @@
931 931  
932 932  [[image:image-20230603122109-13.png||height="469" width="762"]]
933 933  
934 -Data in TTN:
935 935  
946 +**Data in TTN:**
947 +
936 936  [[image:image-20230603122139-14.png||height="148" width="1128"]]
937 937  
938 938  
939 -
940 940  === (% id="cke_bm_1489640S" style="display:none" %) (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.5 Example 5 ~-~- Connect to SIL-400/TEROS-12 & Hygrovue10 ===
941 941  
942 942  ==== 2.6.5.1 Important Notice! ====
943 943  
955 +
944 944  * The product page and reference command see above example 2,3,4
957 +
945 945  * All of these SDI-12 sensors use the same address (address 0) by default. So we need to change their address to different address, by using **aAb!** command. See above example.
959 +
946 946  * The sensor needs to be powered to a steady statue. So the 12VT time need to be set to the maximum stable time for the sensors. in this example, it is 13 seconds.
961 +
947 947  * If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB.
948 948  
964 +
965 +
949 949  ==== 2.6.5.2 Hardware Connection to SDI-12-LB ====
950 950  
968 +
951 951  [[image:image-20230603122508-17.png||height="526" width="742"]]
952 952  
953 953  
954 954  ==== 2.6.5.3 Commands set in SDI-12-LB and uplink payload ====
955 955  
974 +
956 956  [[image:image-20230603122549-18.png]]
957 957  
958 958  [[image:image-20230603122623-19.png||height="483" width="1121"]]
959 959  
960 -Data in TTN:
961 961  
980 +**Data in TTN:**
981 +
962 962  [[image:image-20230603122719-20.png||height="151" width="1179"]]
963 963  
964 964  
965 -
966 -
967 -
968 968  == 2.7 Frequency Plans ==
969 969  
970 970  
... ... @@ -1037,6 +1037,8 @@
1037 1037  * Example 1: Downlink Payload: 0100001E  ~/~/ Set Transmit Interval (TDC) = 30 seconds
1038 1038  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
1039 1039  
1057 +
1058 +
1040 1040  == 3.2 Set Interrupt Mode ==
1041 1041  
1042 1042  
... ... @@ -1068,6 +1068,8 @@
1068 1068  * Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
1069 1069  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
1070 1070  
1090 +
1091 +
1071 1071  == 3.3 Set the output time ==
1072 1072  
1073 1073  
... ... @@ -1137,6 +1137,8 @@
1137 1137  * Example 5: Downlink Payload: 070301F4  **~-~-->**  AT+12VT=500
1138 1138  * Example 6: Downlink Payload: 07030000  **~-~-->**  AT+12VT=0
1139 1139  
1161 +
1162 +
1140 1140  == 3.4 Set the all data mode ==
1141 1141  
1142 1142  
... ... @@ -1159,6 +1159,8 @@
1159 1159  * Example 1: Downlink Payload: AB 00  ~/~/  AT+ALLDATAMOD=0
1160 1160  * Example 2: Downlink Payload: AB 01  ~/~/  AT+ALLDATAMOD=1
1161 1161  
1185 +
1186 +
1162 1162  == 3.5 Set the splicing payload for uplink ==
1163 1163  
1164 1164  
... ... @@ -1215,6 +1215,8 @@
1215 1215  * Example 1: Downlink Payload: AE 01  ~/~/  AT+PAYVER=1
1216 1216  * Example 2: Downlink Payload: AE 05  ~/~/  AT+PAYVER=5
1217 1217  
1243 +
1244 +
1218 1218  = 4. Battery & Power Consumption =
1219 1219  
1220 1220  
... ... @@ -1301,6 +1301,8 @@
1301 1301  * Package Size / pcs : cm
1302 1302  * Weight / pcs : g
1303 1303  
1331 +
1332 +
1304 1304  = 10. ​Support =
1305 1305  
1306 1306  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0