Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Xiaoling on 2025/04/25 08:58
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Xiaoling - Content
-
... ... @@ -65,6 +65,8 @@ 65 65 * Downlink to change configure 66 66 * 8500mAh Battery for long term use 67 67 68 + 69 + 68 68 == 1.3 Specification == 69 69 70 70 ... ... @@ -113,10 +113,11 @@ 113 113 * Sleep Mode: 5uA @ 3.3v 114 114 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 115 115 116 -== 1.4 Connect to SDI-12 Sensor == 117 117 118 118 120 +== 1.4 Connect to SDI-12 Sensor == 119 119 122 + 120 120 [[image:1675212538524-889.png||_mstalt="298272"]] 121 121 122 122 ... ... @@ -147,6 +147,8 @@ 147 147 ))) 148 148 |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode. 149 149 153 + 154 + 150 150 == 1.7 Pin Mapping == 151 151 152 152 ... ... @@ -201,7 +201,6 @@ 201 201 202 202 Each SDI-12-LB is shipped with a sticker with the default device EUI as below: 203 203 204 - 205 205 [[image:image-20230426084456-1.png||height="241" width="519"]] 206 206 207 207 ... ... @@ -396,7 +396,7 @@ 396 396 This command can be used to debug all SDI-12 command. 397 397 398 398 399 -LoRaWAN Downlink: A8 aa xx xx xx xx bb cc 403 +LoRaWAN Downlink: A8 aa xx xx xx xx bb cc dd 400 400 401 401 (% style="color:#037691" %)**aa **(%%): total SDI-12 command length 402 402 ... ... @@ -406,9 +406,11 @@ 406 406 407 407 (% style="color:#037691" %)**cc **(%%): 0: don't uplink return to LoRaWAN, 1: Uplink return to LoRaWAN on FPORT=100 408 408 413 +(% style="color:#037691" %)**dd: **(%%) 0: Do not use aD0! command access, 1: use aD0! command access. 409 409 410 -(% style="color:blue" %)**Example: **(%%) AT+CFGDEV =0RC0!,1 411 411 416 +(% style="color:blue" %)**Example1: **(%%) AT+CFGDEV =0RC0!,1 417 + 412 412 (% style="color:#037691" %)**0RC0! **(%%): SDI-12 Command, 413 413 414 414 (% style="color:#037691" %)**1 **(%%): Delay 1 second. ( 0: 810 mini-second) ... ... @@ -425,6 +425,17 @@ 425 425 [[image:image-20230201092355-17.png||_mstalt="454337" height="426" width="1135"]] 426 426 427 427 434 +(% style="color:blue" %)**Example2: **(%%) AT+CFGDEV =0M!,1,1 or AT+CFGDEV =0C!,1,1 435 + 436 +(% style="color:#037691" %)**0M! **(%%): SDI-12 Command, 437 + 438 +(% style="color:#037691" %)**1 **(%%): Delay 1 second. ( 0: 810 mini-second) 439 + 440 +(% style="color:#037691" %)**1 **(%%):Use aD0! command access. 441 + 442 +Equal Downlink: 0xA8 03 30 4D 21 01 01 01 443 + 444 + 428 428 === 2.3.3 Convert ASCII to String === 429 429 430 430 ... ... @@ -630,33 +630,33 @@ 630 630 631 631 (% style="color:#037691" %)**Frequency Band**: 632 632 633 - *0x01: EU868650 +0x01: EU868 634 634 635 - *0x02: US915652 +0x02: US915 636 636 637 - *0x03: IN865654 +0x03: IN865 638 638 639 - *0x04: AU915656 +0x04: AU915 640 640 641 - *0x05: KZ865658 +0x05: KZ865 642 642 643 - *0x06: RU864660 +0x06: RU864 644 644 645 - *0x07: AS923662 +0x07: AS923 646 646 647 - *0x08: AS923-1664 +0x08: AS923-1 648 648 649 - *0x09: AS923-2666 +0x09: AS923-2 650 650 651 - *0x0a: AS923-3668 +0x0a: AS923-3 652 652 653 - *0x0b: CN470670 +0x0b: CN470 654 654 655 - *0x0c: EU433672 +0x0c: EU433 656 656 657 - *0x0d: KR920674 +0x0d: KR920 658 658 659 - *0x0e: MA869676 +0x0e: MA869 660 660 661 661 662 662 (% style="color:#037691" %)**Sub-Band**: ... ... @@ -687,9 +687,9 @@ 687 687 * Periodically Uplink: FPORT=2 688 688 689 689 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %) 690 -|=(% style="width: 90px;background-color:#D9E2F3" %)((( 707 +|=(% style="width: 90px;background-color:#D9E2F3;color:#0070C0" %)((( 691 691 **Size(bytes)** 692 -)))|=(% style="width: 80px;background-color:#D9E2F3" %)**2**|=(% style="width: 90px;background-color:#D9E2F3" %)**1**|=(% style="width: 240px;background-color:#D9E2F3" %)**Length depends on the return from the commands** 709 +)))|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 90px;background-color:#D9E2F3;color:#0070C0" %)**1**|=(% style="width: 240px;background-color:#D9E2F3;color:#0070C0" %)**Length depends on the return from the commands** 693 693 |(% style="width:93px" %)**Value**|(% style="width:83px" %)((( 694 694 Battery(mV) 695 695 & ... ... @@ -823,18 +823,20 @@ 823 823 824 824 ==== 2.6.2.1 Reference Manual and Command ==== 825 825 843 + 826 826 * [[Hygrovue10 Product Page>>https://www.campbellsci.com/hygrovue10]] 845 + 827 827 * Commands to be used in PC and output. 828 828 829 -1.check device address 848 +~1. check device address 830 830 831 -2.change device address 850 +2. change device address 832 832 833 -3.check device ID 852 +3. check device ID 834 834 835 -4.start measure 854 +4. start measure 836 836 837 -5.Get Meausre result 856 +5. Get Meausre result 838 838 839 839 [[image:image-20230603120209-2.png||height="281" width="267"]] 840 840 ... ... @@ -841,17 +841,20 @@ 841 841 842 842 ==== 2.6.2.2 Hardware Connection to SDI-12-LB ==== 843 843 863 + 844 844 [[image:image-20230603120515-3.png]] 845 845 846 846 847 847 ==== 2.6.2.3 Commands set in SDI-12-LB and uplink payload ==== 848 848 869 + 849 849 [[image:image-20230603120648-4.png]] 850 850 851 851 [[image:image-20230603120726-5.png]] 852 852 853 -Data in TTN: 854 854 875 +**Data in TTN:** 876 + 855 855 [[image:image-20230603120859-6.png||height="118" width="1285"]] 856 856 857 857 ... ... @@ -859,18 +859,20 @@ 859 859 860 860 ==== 2.6.3.1 Reference Manual and Command ==== 861 861 884 + 862 862 * [[SIL-400 Product Page>>https://www.apogeeinstruments.com/sil-411-commercial-grade-sdi-12-digital-output-standard-field-of-view-infrared-radiometer-sensor/]] 886 + 863 863 * Commands to be used in PC and output. 864 864 865 -1.check device address 889 +~1. check device address 866 866 867 -2.change device address 891 +2. change device address 868 868 869 -3.check device ID 893 +3. check device ID 870 870 871 -4.start measure 895 +4. start measure 872 872 873 -5.Get Meausre result 897 +5. Get Meausre result 874 874 875 875 [[image:image-20230603121606-7.png||height="242" width="307"]] 876 876 ... ... @@ -877,11 +877,13 @@ 877 877 878 878 ==== 2.6.3.2 Hardware Connection to SDI-12-LB ==== 879 879 904 + 880 880 [[image:image-20230603121643-8.png||height="442" width="656"]] 881 881 882 882 883 883 ==== 2.6.3.3 Commands set in SDI-12-LB and uplink payload ==== 884 884 910 + 885 885 [[image:image-20230603121721-9.png]] 886 886 887 887 [[image:image-20230603121752-10.png]] ... ... @@ -894,10 +894,11 @@ 894 894 895 895 === (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.4 Example 4 ~-~- Connect to TEROS-12 === 896 896 897 - 898 898 ==== 2.6.4.1 Reference Manual and Command ==== 899 899 925 + 900 900 * [[TEROS-12 Product Page>>https://www.metergroup.com/en/meter-environment/products/teros-12-soil-moisture-sensor]] 927 + 901 901 * Commands to be used in PC and output. 902 902 903 903 1.check device address ... ... @@ -915,6 +915,7 @@ 915 915 916 916 ==== 2.6.4.2 Hardware Connection to SDI-12-LB ==== 917 917 945 + 918 918 [[image:image-20230603122212-15.png||height="502" width="667"]] 919 919 920 920 ... ... @@ -924,41 +924,44 @@ 924 924 925 925 [[image:image-20230603122109-13.png||height="469" width="762"]] 926 926 927 -Data in TTN: 928 928 956 +**Data in TTN:** 957 + 929 929 [[image:image-20230603122139-14.png||height="148" width="1128"]] 930 930 931 931 932 - 933 933 === (% id="cke_bm_1489640S" style="display:none" %) (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.5 Example 5 ~-~- Connect to SIL-400/TEROS-12 & Hygrovue10 === 934 934 935 935 ==== 2.6.5.1 Important Notice! ==== 936 936 965 + 937 937 * The product page and reference command see above example 2,3,4 967 + 938 938 * All of these SDI-12 sensors use the same address (address 0) by default. So we need to change their address to different address, by using **aAb!** command. See above example. 969 + 939 939 * The sensor needs to be powered to a steady statue. So the 12VT time need to be set to the maximum stable time for the sensors. in this example, it is 13 seconds. 971 + 940 940 * If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB. 941 941 942 - 943 943 ==== 2.6.5.2 Hardware Connection to SDI-12-LB ==== 944 944 976 + 945 945 [[image:image-20230603122508-17.png||height="526" width="742"]] 946 946 947 947 948 948 ==== 2.6.5.3 Commands set in SDI-12-LB and uplink payload ==== 949 949 982 + 950 950 [[image:image-20230603122549-18.png]] 951 951 952 952 [[image:image-20230603122623-19.png||height="483" width="1121"]] 953 953 954 -Data in TTN: 955 955 988 +**Data in TTN:** 989 + 956 956 [[image:image-20230603122719-20.png||height="151" width="1179"]] 957 957 958 958 959 - 960 - 961 - 962 962 == 2.7 Frequency Plans == 963 963 964 964 ... ... @@ -1105,8 +1105,10 @@ 1105 1105 OK 1106 1106 ))) 1107 1107 1108 -(% style="color:blue" %)**AT Command: AT+12VT** 1139 +(% style="color:blue" %)**AT Command: AT+12VT ** 1109 1109 1141 +(% style="color:blue" %)**(The v1.2 version is enabled for 1 second by default, and the version below v1.2 is disabled by default)** 1142 + 1110 1110 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:443px" %) 1111 1111 |=(% style="width: 156px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 199px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 83px;background-color:#D9E2F3;color:#0070C0" %)**Response** 1112 1112 |(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=?|(% style="background-color:#f2f2f2; width:199px" %)Show 12V open time.|(% style="background-color:#f2f2f2; width:83px" %)(((