... ... @@ -399,7 +399,7 @@
399 399  This command can be used to debug all SDI-12 command.
400 400  
401 401  
402 -LoRaWAN Downlink: A8 aa xx xx xx xx bb cc
402 +LoRaWAN Downlink: A8 aa xx xx xx xx bb cc dd
403 403  
404 404  (% style="color:#037691" %)**aa **(%%): total SDI-12 command length
405 405  
... ... @@ -409,9 +409,11 @@
409 409  
410 410  (% style="color:#037691" %)**cc **(%%): 0: don't uplink return to LoRaWAN, 1: Uplink return to LoRaWAN on FPORT=100
411 411  
412 +(% style="color:#037691" %)**dd: **(%%) 0: Do not use aD0! command access, 1: use aD0! command access.
412 412  
413 -(% style="color:blue" %)**Example: **(%%) AT+CFGDEV =0RC0!,1
414 414  
415 +(% style="color:blue" %)**Example1: **(%%) AT+CFGDEV =0RC0!,1
416 +
415 415  (% style="color:#037691" %)**0RC0! **(%%): SDI-12 Command,
416 416  
417 417  (% style="color:#037691" %)**1 **(%%): Delay 1 second.  ( 0: 810 mini-second)
... ... @@ -428,6 +428,17 @@
428 428  [[image:image-20230201092355-17.png||_mstalt="454337" height="426" width="1135"]]
429 429  
430 430  
433 +(% style="color:blue" %)**Example2: **(%%) AT+CFGDEV =0M!,1,1  or  AT+CFGDEV =0C!,1,1
434 +
435 +(% style="color:#037691" %)**0M! **(%%): SDI-12 Command,
436 +
437 +(% style="color:#037691" %)**1 **(%%): Delay 1 second.  ( 0: 810 mini-second)
438 +
439 +(% style="color:#037691" %)**1 **(%%):Use aD0! command access.
440 +
441 +Equal Downlink: 0xA8 03 30  4D 21 01 01 01
442 +
443 +
431 431  === 2.3.3 Convert ASCII to String ===
432 432  
433 433  
... ... @@ -822,22 +822,24 @@
822 822  Partial cut, the cut sensor address and the first two parameters:(% style="color:#037691" %)**AT+DATACUTx=25,2,1~~12, cut out the character field ” 4+30.8+22.84”**.
823 823  
824 824  
825 -=== 2.6.2 Example ~-~- Connect to Hygrovue10 ===
838 +=== 2.6.2 Example 2 ~-~- Connect to Hygrovue10 ===
826 826  
827 827  ==== 2.6.2.1 Reference Manual and Command ====
828 828  
842 +
829 829  * [[Hygrovue10 Product Page>>https://www.campbellsci.com/hygrovue10]]
844 +
830 830  * Commands to be used in PC and output.
831 831  
832 -1.check device address
847 +~1. check device address
833 833  
834 -2.change device address
849 +2. change device address
835 835  
836 -3.check device ID
851 +3. check device ID
837 837  
838 -4.start measure
853 +4. start measure
839 839  
840 -5.Get Meausre result
855 +5. Get Meausre result
841 841  
842 842  [[image:image-20230603120209-2.png||height="281" width="267"]]
843 843  
... ... @@ -844,22 +844,137 @@
844 844  
845 845  ==== 2.6.2.2 Hardware Connection to SDI-12-LB ====
846 846  
862 +
847 847  [[image:image-20230603120515-3.png]]
848 848  
849 849  
850 850  ==== 2.6.2.3 Commands set in SDI-12-LB and uplink payload ====
851 851  
868 +
852 852  [[image:image-20230603120648-4.png]]
853 853  
854 854  [[image:image-20230603120726-5.png]]
855 855  
856 -Data in TTN:
857 857  
874 +**Data in TTN:**
875 +
858 858  [[image:image-20230603120859-6.png||height="118" width="1285"]]
859 859  
860 860  
879 +=== (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.3 Example 3 ~-~- Connect to SIL-400 ===
861 861  
881 +==== 2.6.3.1 Reference Manual and Command ====
862 862  
883 +
884 +* [[SIL-400 Product Page>>https://www.apogeeinstruments.com/sil-411-commercial-grade-sdi-12-digital-output-standard-field-of-view-infrared-radiometer-sensor/]]
885 +
886 +* Commands to be used in PC and output.
887 +
888 +~1. check device address
889 +
890 +2. change device address
891 +
892 +3. check device ID
893 +
894 +4. start measure
895 +
896 +5. Get Meausre result
897 +
898 +[[image:image-20230603121606-7.png||height="242" width="307"]]
899 +
900 +
901 +==== 2.6.3.2 Hardware Connection to SDI-12-LB ====
902 +
903 +
904 +[[image:image-20230603121643-8.png||height="442" width="656"]]
905 +
906 +
907 +==== 2.6.3.3 Commands set in SDI-12-LB and uplink payload ====
908 +
909 +
910 +[[image:image-20230603121721-9.png]]
911 +
912 +[[image:image-20230603121752-10.png]]
913 +
914 +Data in TTN:
915 +
916 +[[image:image-20230603121826-11.png||height="155" width="1104"]]
917 +
918 +
919 +
920 +=== (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.4 Example 4 ~-~- Connect to TEROS-12 ===
921 +
922 +==== 2.6.4.1 Reference Manual and Command ====
923 +
924 +
925 +* [[TEROS-12 Product Page>>https://www.metergroup.com/en/meter-environment/products/teros-12-soil-moisture-sensor]]
926 +
927 +* Commands to be used in PC and output.
928 +
929 +1.check device address
930 +
931 +2.change device address
932 +
933 +3.check device ID
934 +
935 +4.start measure
936 +
937 +5.Get Meausre result
938 +
939 +[[image:image-20230603122248-16.png||height="196" width="198"]]
940 +
941 +
942 +==== 2.6.4.2 Hardware Connection to SDI-12-LB ====
943 +
944 +
945 +[[image:image-20230603122212-15.png||height="502" width="667"]]
946 +
947 +
948 +==== 2.6.4.3 Commands set in SDI-12-LB and uplink payload ====
949 +
950 +[[image:image-20230603122040-12.png]]
951 +
952 +[[image:image-20230603122109-13.png||height="469" width="762"]]
953 +
954 +
955 +**Data in TTN:**
956 +
957 +[[image:image-20230603122139-14.png||height="148" width="1128"]]
958 +
959 +
960 +=== (% id="cke_bm_1489640S" style="display:none" %) (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.5 Example 5 ~-~- Connect to SIL-400/TEROS-12 & Hygrovue10 ===
961 +
962 +==== 2.6.5.1 Important Notice! ====
963 +
964 +
965 +* The product page and reference command see above example 2,3,4
966 +
967 +* All of these SDI-12 sensors use the same address (address 0) by default. So we need to change their address to different address, by using **aAb!** command. See above example.
968 +
969 +* The sensor needs to be powered to a steady statue. So the 12VT time need to be set to the maximum stable time for the sensors. in this example, it is 13 seconds.
970 +
971 +* If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB.
972 +
973 +
974 +==== 2.6.5.2 Hardware Connection to SDI-12-LB ====
975 +
976 +
977 +[[image:image-20230603122508-17.png||height="526" width="742"]]
978 +
979 +
980 +==== 2.6.5.3 Commands set in SDI-12-LB and uplink payload ====
981 +
982 +
983 +[[image:image-20230603122549-18.png]]
984 +
985 +[[image:image-20230603122623-19.png||height="483" width="1121"]]
986 +
987 +
988 +**Data in TTN:**
989 +
990 +[[image:image-20230603122719-20.png||height="151" width="1179"]]
991 +
992 +
863 863  == 2.7 Frequency Plans ==
864 864  
865 865  
... ... @@ -1008,8 +1008,10 @@
1008 1008  OK
1009 1009  )))
1010 1010  
1011 -(% style="color:blue" %)**AT Command: AT+12VT**
1141 +(% style="color:blue" %)**AT Command: AT+12VT **
1012 1012  
1143 +(% style="color:blue" %)**(The v1.2 version is enabled for 1 second by default, and the version below v1.2 is disabled by default)**
1144 +
1013 1013  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:443px" %)
1014 1014  |=(% style="width: 156px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 199px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 83px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1015 1015  |(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=?|(% style="background-color:#f2f2f2; width:199px" %)Show 12V open time.|(% style="background-color:#f2f2f2; width:83px" %)(((