Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Xiaoling on 2025/04/25 08:58
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Saxer - Content
-
... ... @@ -399,7 +399,7 @@ 399 399 This command can be used to debug all SDI-12 command. 400 400 401 401 402 -LoRaWAN Downlink: A8 aa xx xx xx xx bb cc 402 +LoRaWAN Downlink: A8 aa xx xx xx xx bb cc dd 403 403 404 404 (% style="color:#037691" %)**aa **(%%): total SDI-12 command length 405 405 ... ... @@ -409,9 +409,11 @@ 409 409 410 410 (% style="color:#037691" %)**cc **(%%): 0: don't uplink return to LoRaWAN, 1: Uplink return to LoRaWAN on FPORT=100 411 411 412 +(% style="color:#037691" %)**dd: **(%%) 0: Do not use aD0! command access, 1: use aD0! command access. 412 412 413 -(% style="color:blue" %)**Example: **(%%) AT+CFGDEV =0RC0!,1 414 414 415 +(% style="color:blue" %)**Example1: **(%%) AT+CFGDEV =0RC0!,1 416 + 415 415 (% style="color:#037691" %)**0RC0! **(%%): SDI-12 Command, 416 416 417 417 (% style="color:#037691" %)**1 **(%%): Delay 1 second. ( 0: 810 mini-second) ... ... @@ -428,6 +428,17 @@ 428 428 [[image:image-20230201092355-17.png||_mstalt="454337" height="426" width="1135"]] 429 429 430 430 433 +(% style="color:blue" %)**Example2: **(%%) AT+CFGDEV =0M!,1,1 or AT+CFGDEV =0C!,1,1 434 + 435 +(% style="color:#037691" %)**0M! **(%%): SDI-12 Command, 436 + 437 +(% style="color:#037691" %)**1 **(%%): Delay 1 second. ( 0: 810 mini-second) 438 + 439 +(% style="color:#037691" %)**1 **(%%):Use aD0! command access. 440 + 441 +Equal Downlink: 0xA8 03 30 4D 21 01 01 01 442 + 443 + 431 431 === 2.3.3 Convert ASCII to String === 432 432 433 433 ... ... @@ -822,22 +822,24 @@ 822 822 Partial cut, the cut sensor address and the first two parameters:(% style="color:#037691" %)**AT+DATACUTx=25,2,1~~12, cut out the character field ” 4+30.8+22.84”**. 823 823 824 824 825 -=== 2.6.2 Example ~-~- Connect to Hygrovue10 === 838 +=== 2.6.2 Example 2 ~-~- Connect to Hygrovue10 === 826 826 827 827 ==== 2.6.2.1 Reference Manual and Command ==== 828 828 842 + 829 829 * [[Hygrovue10 Product Page>>https://www.campbellsci.com/hygrovue10]] 844 + 830 830 * Commands to be used in PC and output. 831 831 832 -1.check device address 847 +~1. check device address 833 833 834 -2.change device address 849 +2. change device address 835 835 836 -3.check device ID 851 +3. check device ID 837 837 838 -4.start measure 853 +4. start measure 839 839 840 -5.Get Meausre result 855 +5. Get Meausre result 841 841 842 842 [[image:image-20230603120209-2.png||height="281" width="267"]] 843 843 ... ... @@ -844,22 +844,137 @@ 844 844 845 845 ==== 2.6.2.2 Hardware Connection to SDI-12-LB ==== 846 846 862 + 847 847 [[image:image-20230603120515-3.png]] 848 848 849 849 850 850 ==== 2.6.2.3 Commands set in SDI-12-LB and uplink payload ==== 851 851 868 + 852 852 [[image:image-20230603120648-4.png]] 853 853 854 854 [[image:image-20230603120726-5.png]] 855 855 856 -Data in TTN: 857 857 874 +**Data in TTN:** 875 + 858 858 [[image:image-20230603120859-6.png||height="118" width="1285"]] 859 859 860 860 879 +=== (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.3 Example 3 ~-~- Connect to SIL-400 === 861 861 881 +==== 2.6.3.1 Reference Manual and Command ==== 862 862 883 + 884 +* [[SIL-400 Product Page>>https://www.apogeeinstruments.com/sil-411-commercial-grade-sdi-12-digital-output-standard-field-of-view-infrared-radiometer-sensor/]] 885 + 886 +* Commands to be used in PC and output. 887 + 888 +~1. check device address 889 + 890 +2. change device address 891 + 892 +3. check device ID 893 + 894 +4. start measure 895 + 896 +5. Get Meausre result 897 + 898 +[[image:image-20230603121606-7.png||height="242" width="307"]] 899 + 900 + 901 +==== 2.6.3.2 Hardware Connection to SDI-12-LB ==== 902 + 903 + 904 +[[image:image-20230603121643-8.png||height="442" width="656"]] 905 + 906 + 907 +==== 2.6.3.3 Commands set in SDI-12-LB and uplink payload ==== 908 + 909 + 910 +[[image:image-20230603121721-9.png]] 911 + 912 +[[image:image-20230603121752-10.png]] 913 + 914 +Data in TTN: 915 + 916 +[[image:image-20230603121826-11.png||height="155" width="1104"]] 917 + 918 + 919 + 920 +=== (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.4 Example 4 ~-~- Connect to TEROS-12 === 921 + 922 +==== 2.6.4.1 Reference Manual and Command ==== 923 + 924 + 925 +* [[TEROS-12 Product Page>>https://www.metergroup.com/en/meter-environment/products/teros-12-soil-moisture-sensor]] 926 + 927 +* Commands to be used in PC and output. 928 + 929 +1.check device address 930 + 931 +2.change device address 932 + 933 +3.check device ID 934 + 935 +4.start measure 936 + 937 +5.Get Meausre result 938 + 939 +[[image:image-20230603122248-16.png||height="196" width="198"]] 940 + 941 + 942 +==== 2.6.4.2 Hardware Connection to SDI-12-LB ==== 943 + 944 + 945 +[[image:image-20230603122212-15.png||height="502" width="667"]] 946 + 947 + 948 +==== 2.6.4.3 Commands set in SDI-12-LB and uplink payload ==== 949 + 950 +[[image:image-20230603122040-12.png]] 951 + 952 +[[image:image-20230603122109-13.png||height="469" width="762"]] 953 + 954 + 955 +**Data in TTN:** 956 + 957 +[[image:image-20230603122139-14.png||height="148" width="1128"]] 958 + 959 + 960 +=== (% id="cke_bm_1489640S" style="display:none" %) (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.5 Example 5 ~-~- Connect to SIL-400/TEROS-12 & Hygrovue10 === 961 + 962 +==== 2.6.5.1 Important Notice! ==== 963 + 964 + 965 +* The product page and reference command see above example 2,3,4 966 + 967 +* All of these SDI-12 sensors use the same address (address 0) by default. So we need to change their address to different address, by using **aAb!** command. See above example. 968 + 969 +* The sensor needs to be powered to a steady statue. So the 12VT time need to be set to the maximum stable time for the sensors. in this example, it is 13 seconds. 970 + 971 +* If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB. 972 + 973 + 974 +==== 2.6.5.2 Hardware Connection to SDI-12-LB ==== 975 + 976 + 977 +[[image:image-20230603122508-17.png||height="526" width="742"]] 978 + 979 + 980 +==== 2.6.5.3 Commands set in SDI-12-LB and uplink payload ==== 981 + 982 + 983 +[[image:image-20230603122549-18.png]] 984 + 985 +[[image:image-20230603122623-19.png||height="483" width="1121"]] 986 + 987 + 988 +**Data in TTN:** 989 + 990 +[[image:image-20230603122719-20.png||height="151" width="1179"]] 991 + 992 + 863 863 == 2.7 Frequency Plans == 864 864 865 865 ... ... @@ -1008,8 +1008,10 @@ 1008 1008 OK 1009 1009 ))) 1010 1010 1011 -(% style="color:blue" %)**AT Command: AT+12VT** 1141 +(% style="color:blue" %)**AT Command: AT+12VT ** 1012 1012 1143 +(% style="color:blue" %)**(The v1.2 version is enabled for 1 second by default, and the version below v1.2 is disabled by default)** 1144 + 1013 1013 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:443px" %) 1014 1014 |=(% style="width: 156px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 199px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 83px;background-color:#D9E2F3;color:#0070C0" %)**Response** 1015 1015 |(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=?|(% style="background-color:#f2f2f2; width:199px" %)Show 12V open time.|(% style="background-color:#f2f2f2; width:83px" %)(((