Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Xiaoling on 2025/04/25 08:58
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Xiaoling - Content
-
... ... @@ -65,7 +65,6 @@ 65 65 * Downlink to change configure 66 66 * 8500mAh Battery for long term use 67 67 68 - 69 69 == 1.3 Specification == 70 70 71 71 ... ... @@ -114,7 +114,6 @@ 114 114 * Sleep Mode: 5uA @ 3.3v 115 115 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 116 116 117 - 118 118 == 1.4 Connect to SDI-12 Sensor == 119 119 120 120 ... ... @@ -149,7 +149,6 @@ 149 149 ))) 150 150 |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode. 151 151 152 - 153 153 == 1.7 Pin Mapping == 154 154 155 155 ... ... @@ -822,22 +822,24 @@ 822 822 Partial cut, the cut sensor address and the first two parameters:(% style="color:#037691" %)**AT+DATACUTx=25,2,1~~12, cut out the character field ” 4+30.8+22.84”**. 823 823 824 824 825 -=== 2.6.2 Example ~-~- Connect to Hygrovue10 === 822 +=== 2.6.2 Example 2 ~-~- Connect to Hygrovue10 === 826 826 827 827 ==== 2.6.2.1 Reference Manual and Command ==== 828 828 826 + 829 829 * [[Hygrovue10 Product Page>>https://www.campbellsci.com/hygrovue10]] 828 + 830 830 * Commands to be used in PC and output. 831 831 832 -1.check device address 831 +~1. check device address 833 833 834 -2.change device address 833 +2. change device address 835 835 836 -3.check device ID 835 +3. check device ID 837 837 838 -4.start measure 837 +4. start measure 839 839 840 -5.Get Meausre result 839 +5. Get Meausre result 841 841 842 842 [[image:image-20230603120209-2.png||height="281" width="267"]] 843 843 ... ... @@ -844,22 +844,128 @@ 844 844 845 845 ==== 2.6.2.2 Hardware Connection to SDI-12-LB ==== 846 846 846 + 847 847 [[image:image-20230603120515-3.png]] 848 848 849 849 850 850 ==== 2.6.2.3 Commands set in SDI-12-LB and uplink payload ==== 851 851 852 + 852 852 [[image:image-20230603120648-4.png]] 853 853 854 854 [[image:image-20230603120726-5.png]] 855 855 856 -Data in TTN: 857 857 858 +**Data in TTN:** 859 + 858 858 [[image:image-20230603120859-6.png||height="118" width="1285"]] 859 859 860 860 863 +=== (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.3 Example 3 ~-~- Connect to SIL-400 === 861 861 865 +==== 2.6.3.1 Reference Manual and Command ==== 862 862 867 + 868 +* [[SIL-400 Product Page>>https://www.apogeeinstruments.com/sil-411-commercial-grade-sdi-12-digital-output-standard-field-of-view-infrared-radiometer-sensor/]] 869 + 870 +* Commands to be used in PC and output. 871 + 872 +~1. check device address 873 + 874 +2. change device address 875 + 876 +3. check device ID 877 + 878 +4. start measure 879 + 880 +5. Get Meausre result 881 + 882 +[[image:image-20230603121606-7.png||height="242" width="307"]] 883 + 884 + 885 +==== 2.6.3.2 Hardware Connection to SDI-12-LB ==== 886 + 887 +[[image:image-20230603121643-8.png||height="442" width="656"]] 888 + 889 + 890 +==== 2.6.3.3 Commands set in SDI-12-LB and uplink payload ==== 891 + 892 +[[image:image-20230603121721-9.png]] 893 + 894 +[[image:image-20230603121752-10.png]] 895 + 896 +Data in TTN: 897 + 898 +[[image:image-20230603121826-11.png||height="155" width="1104"]] 899 + 900 + 901 + 902 +=== (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.4 Example 4 ~-~- Connect to TEROS-12 === 903 + 904 + 905 +==== 2.6.4.1 Reference Manual and Command ==== 906 + 907 +* [[TEROS-12 Product Page>>https://www.metergroup.com/en/meter-environment/products/teros-12-soil-moisture-sensor]] 908 +* Commands to be used in PC and output. 909 + 910 +1.check device address 911 + 912 +2.change device address 913 + 914 +3.check device ID 915 + 916 +4.start measure 917 + 918 +5.Get Meausre result 919 + 920 +[[image:image-20230603122248-16.png||height="196" width="198"]] 921 + 922 + 923 +==== 2.6.4.2 Hardware Connection to SDI-12-LB ==== 924 + 925 +[[image:image-20230603122212-15.png||height="502" width="667"]] 926 + 927 + 928 +==== 2.6.4.3 Commands set in SDI-12-LB and uplink payload ==== 929 + 930 +[[image:image-20230603122040-12.png]] 931 + 932 +[[image:image-20230603122109-13.png||height="469" width="762"]] 933 + 934 +Data in TTN: 935 + 936 +[[image:image-20230603122139-14.png||height="148" width="1128"]] 937 + 938 + 939 + 940 +=== (% id="cke_bm_1489640S" style="display:none" %) (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.5 Example 5 ~-~- Connect to SIL-400/TEROS-12 & Hygrovue10 === 941 + 942 +==== 2.6.5.1 Important Notice! ==== 943 + 944 +* The product page and reference command see above example 2,3,4 945 +* All of these SDI-12 sensors use the same address (address 0) by default. So we need to change their address to different address, by using **aAb!** command. See above example. 946 +* The sensor needs to be powered to a steady statue. So the 12VT time need to be set to the maximum stable time for the sensors. in this example, it is 13 seconds. 947 +* If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB. 948 + 949 +==== 2.6.5.2 Hardware Connection to SDI-12-LB ==== 950 + 951 +[[image:image-20230603122508-17.png||height="526" width="742"]] 952 + 953 + 954 +==== 2.6.5.3 Commands set in SDI-12-LB and uplink payload ==== 955 + 956 +[[image:image-20230603122549-18.png]] 957 + 958 +[[image:image-20230603122623-19.png||height="483" width="1121"]] 959 + 960 +Data in TTN: 961 + 962 +[[image:image-20230603122719-20.png||height="151" width="1179"]] 963 + 964 + 965 + 966 + 967 + 863 863 == 2.7 Frequency Plans == 864 864 865 865 ... ... @@ -932,7 +932,6 @@ 932 932 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 933 933 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 934 934 935 - 936 936 == 3.2 Set Interrupt Mode == 937 937 938 938 ... ... @@ -964,7 +964,6 @@ 964 964 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 965 965 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 966 966 967 - 968 968 == 3.3 Set the output time == 969 969 970 970 ... ... @@ -1034,7 +1034,6 @@ 1034 1034 * Example 5: Downlink Payload: 070301F4 **~-~-->** AT+12VT=500 1035 1035 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 1036 1036 1037 - 1038 1038 == 3.4 Set the all data mode == 1039 1039 1040 1040 ... ... @@ -1057,7 +1057,6 @@ 1057 1057 * Example 1: Downlink Payload: AB 00 ~/~/ AT+ALLDATAMOD=0 1058 1058 * Example 2: Downlink Payload: AB 01 ~/~/ AT+ALLDATAMOD=1 1059 1059 1060 - 1061 1061 == 3.5 Set the splicing payload for uplink == 1062 1062 1063 1063 ... ... @@ -1114,7 +1114,6 @@ 1114 1114 * Example 1: Downlink Payload: AE 01 ~/~/ AT+PAYVER=1 1115 1115 * Example 2: Downlink Payload: AE 05 ~/~/ AT+PAYVER=5 1116 1116 1117 - 1118 1118 = 4. Battery & Power Consumption = 1119 1119 1120 1120 ... ... @@ -1201,7 +1201,6 @@ 1201 1201 * Package Size / pcs : cm 1202 1202 * Weight / pcs : g 1203 1203 1204 - 1205 1205 = 10. Support = 1206 1206 1207 1207