... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.Xiaoling
Content
... ... @@ -65,7 +65,6 @@
65 65  * Downlink to change configure
66 66  * 8500mAh Battery for long term use
67 67  
68 -
69 69  == 1.3 Specification ==
70 70  
71 71  
... ... @@ -114,7 +114,6 @@
114 114  * Sleep Mode: 5uA @ 3.3v
115 115  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
116 116  
117 -
118 118  == 1.4 Connect to SDI-12 Sensor ==
119 119  
120 120  
... ... @@ -149,7 +149,6 @@
149 149  )))
150 150  |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode.
151 151  
152 -
153 153  == 1.7 Pin Mapping ==
154 154  
155 155  
... ... @@ -822,22 +822,24 @@
822 822  Partial cut, the cut sensor address and the first two parameters:(% style="color:#037691" %)**AT+DATACUTx=25,2,1~~12, cut out the character field ” 4+30.8+22.84”**.
823 823  
824 824  
825 -=== 2.6.2 Example ~-~- Connect to Hygrovue10 ===
822 +=== 2.6.2 Example 2 ~-~- Connect to Hygrovue10 ===
826 826  
827 827  ==== 2.6.2.1 Reference Manual and Command ====
828 828  
826 +
829 829  * [[Hygrovue10 Product Page>>https://www.campbellsci.com/hygrovue10]]
828 +
830 830  * Commands to be used in PC and output.
831 831  
832 -1.check device address
831 +~1. check device address
833 833  
834 -2.change device address
833 +2. change device address
835 835  
836 -3.check device ID
835 +3. check device ID
837 837  
838 -4.start measure
837 +4. start measure
839 839  
840 -5.Get Meausre result
839 +5. Get Meausre result
841 841  
842 842  [[image:image-20230603120209-2.png||height="281" width="267"]]
843 843  
... ... @@ -844,22 +844,128 @@
844 844  
845 845  ==== 2.6.2.2 Hardware Connection to SDI-12-LB ====
846 846  
846 +
847 847  [[image:image-20230603120515-3.png]]
848 848  
849 849  
850 850  ==== 2.6.2.3 Commands set in SDI-12-LB and uplink payload ====
851 851  
852 +
852 852  [[image:image-20230603120648-4.png]]
853 853  
854 854  [[image:image-20230603120726-5.png]]
855 855  
856 -Data in TTN:
857 857  
858 +**Data in TTN:**
859 +
858 858  [[image:image-20230603120859-6.png||height="118" width="1285"]]
859 859  
860 860  
863 +=== (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.3 Example 3 ~-~- Connect to SIL-400 ===
861 861  
865 +==== 2.6.3.1 Reference Manual and Command ====
862 862  
867 +
868 +* [[SIL-400 Product Page>>https://www.apogeeinstruments.com/sil-411-commercial-grade-sdi-12-digital-output-standard-field-of-view-infrared-radiometer-sensor/]]
869 +
870 +* Commands to be used in PC and output.
871 +
872 +~1. check device address
873 +
874 +2. change device address
875 +
876 +3. check device ID
877 +
878 +4. start measure
879 +
880 +5. Get Meausre result
881 +
882 +[[image:image-20230603121606-7.png||height="242" width="307"]]
883 +
884 +
885 +==== 2.6.3.2 Hardware Connection to SDI-12-LB ====
886 +
887 +[[image:image-20230603121643-8.png||height="442" width="656"]]
888 +
889 +
890 +==== 2.6.3.3 Commands set in SDI-12-LB and uplink payload ====
891 +
892 +[[image:image-20230603121721-9.png]]
893 +
894 +[[image:image-20230603121752-10.png]]
895 +
896 +Data in TTN:
897 +
898 +[[image:image-20230603121826-11.png||height="155" width="1104"]]
899 +
900 +
901 +
902 +=== (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.4 Example 4 ~-~- Connect to TEROS-12 ===
903 +
904 +
905 +==== 2.6.4.1 Reference Manual and Command ====
906 +
907 +* [[TEROS-12 Product Page>>https://www.metergroup.com/en/meter-environment/products/teros-12-soil-moisture-sensor]]
908 +* Commands to be used in PC and output.
909 +
910 +1.check device address
911 +
912 +2.change device address
913 +
914 +3.check device ID
915 +
916 +4.start measure
917 +
918 +5.Get Meausre result
919 +
920 +[[image:image-20230603122248-16.png||height="196" width="198"]]
921 +
922 +
923 +==== 2.6.4.2 Hardware Connection to SDI-12-LB ====
924 +
925 +[[image:image-20230603122212-15.png||height="502" width="667"]]
926 +
927 +
928 +==== 2.6.4.3 Commands set in SDI-12-LB and uplink payload ====
929 +
930 +[[image:image-20230603122040-12.png]]
931 +
932 +[[image:image-20230603122109-13.png||height="469" width="762"]]
933 +
934 +Data in TTN:
935 +
936 +[[image:image-20230603122139-14.png||height="148" width="1128"]]
937 +
938 +
939 +
940 +=== (% id="cke_bm_1489640S" style="display:none" %) (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.5 Example 5 ~-~- Connect to SIL-400/TEROS-12 & Hygrovue10 ===
941 +
942 +==== 2.6.5.1 Important Notice! ====
943 +
944 +* The product page and reference command see above example 2,3,4
945 +* All of these SDI-12 sensors use the same address (address 0) by default. So we need to change their address to different address, by using **aAb!** command. See above example.
946 +* The sensor needs to be powered to a steady statue. So the 12VT time need to be set to the maximum stable time for the sensors. in this example, it is 13 seconds.
947 +* If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB.
948 +
949 +==== 2.6.5.2 Hardware Connection to SDI-12-LB ====
950 +
951 +[[image:image-20230603122508-17.png||height="526" width="742"]]
952 +
953 +
954 +==== 2.6.5.3 Commands set in SDI-12-LB and uplink payload ====
955 +
956 +[[image:image-20230603122549-18.png]]
957 +
958 +[[image:image-20230603122623-19.png||height="483" width="1121"]]
959 +
960 +Data in TTN:
961 +
962 +[[image:image-20230603122719-20.png||height="151" width="1179"]]
963 +
964 +
965 +
966 +
967 +
863 863  == 2.7 Frequency Plans ==
864 864  
865 865  
... ... @@ -932,7 +932,6 @@
932 932  * Example 1: Downlink Payload: 0100001E  ~/~/ Set Transmit Interval (TDC) = 30 seconds
933 933  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
934 934  
935 -
936 936  == 3.2 Set Interrupt Mode ==
937 937  
938 938  
... ... @@ -964,7 +964,6 @@
964 964  * Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
965 965  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
966 966  
967 -
968 968  == 3.3 Set the output time ==
969 969  
970 970  
... ... @@ -1034,7 +1034,6 @@
1034 1034  * Example 5: Downlink Payload: 070301F4  **~-~-->**  AT+12VT=500
1035 1035  * Example 6: Downlink Payload: 07030000  **~-~-->**  AT+12VT=0
1036 1036  
1037 -
1038 1038  == 3.4 Set the all data mode ==
1039 1039  
1040 1040  
... ... @@ -1057,7 +1057,6 @@
1057 1057  * Example 1: Downlink Payload: AB 00  ~/~/  AT+ALLDATAMOD=0
1058 1058  * Example 2: Downlink Payload: AB 01  ~/~/  AT+ALLDATAMOD=1
1059 1059  
1060 -
1061 1061  == 3.5 Set the splicing payload for uplink ==
1062 1062  
1063 1063  
... ... @@ -1114,7 +1114,6 @@
1114 1114  * Example 1: Downlink Payload: AE 01  ~/~/  AT+PAYVER=1
1115 1115  * Example 2: Downlink Payload: AE 05  ~/~/  AT+PAYVER=5
1116 1116  
1117 -
1118 1118  = 4. Battery & Power Consumption =
1119 1119  
1120 1120  
... ... @@ -1201,7 +1201,6 @@
1201 1201  * Package Size / pcs : cm
1202 1202  * Weight / pcs : g
1203 1203  
1204 -
1205 1205  = 10. ​Support =
1206 1206  
1207 1207  
image-20230603122623-19.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Edwin
Size
... ... @@ -1,0 +1,1 @@
1 +139.5 KB
Content
image-20230603122719-20.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Edwin
Size
... ... @@ -1,0 +1,1 @@
1 +83.8 KB
Content