Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Xiaoling on 2025/04/25 08:58
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Xiaoling - Content
-
... ... @@ -66,6 +66,7 @@ 66 66 * 8500mAh Battery for long term use 67 67 68 68 69 + 69 69 == 1.3 Specification == 70 70 71 71 ... ... @@ -115,6 +115,7 @@ 115 115 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 116 116 117 117 119 + 118 118 == 1.4 Connect to SDI-12 Sensor == 119 119 120 120 ... ... @@ -150,6 +150,7 @@ 150 150 |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode. 151 151 152 152 155 + 153 153 == 1.7 Pin Mapping == 154 154 155 155 ... ... @@ -822,22 +822,24 @@ 822 822 Partial cut, the cut sensor address and the first two parameters:(% style="color:#037691" %)**AT+DATACUTx=25,2,1~~12, cut out the character field ” 4+30.8+22.84”**. 823 823 824 824 825 -=== 2.6.2 Example ~-~- Connect to Hygrovue10 === 828 +=== 2.6.2 Example 2 ~-~- Connect to Hygrovue10 === 826 826 827 827 ==== 2.6.2.1 Reference Manual and Command ==== 828 828 832 + 829 829 * [[Hygrovue10 Product Page>>https://www.campbellsci.com/hygrovue10]] 834 + 830 830 * Commands to be used in PC and output. 831 831 832 -1.check device address 837 +~1. check device address 833 833 834 -2.change device address 839 +2. change device address 835 835 836 -3.check device ID 841 +3. check device ID 837 837 838 -4.start measure 843 +4. start measure 839 839 840 -5.Get Meausre result 845 +5. Get Meausre result 841 841 842 842 [[image:image-20230603120209-2.png||height="281" width="267"]] 843 843 ... ... @@ -844,22 +844,139 @@ 844 844 845 845 ==== 2.6.2.2 Hardware Connection to SDI-12-LB ==== 846 846 852 + 847 847 [[image:image-20230603120515-3.png]] 848 848 849 849 850 850 ==== 2.6.2.3 Commands set in SDI-12-LB and uplink payload ==== 851 851 858 + 852 852 [[image:image-20230603120648-4.png]] 853 853 854 854 [[image:image-20230603120726-5.png]] 855 855 856 -Data in TTN: 857 857 864 +**Data in TTN:** 865 + 858 858 [[image:image-20230603120859-6.png||height="118" width="1285"]] 859 859 860 860 869 +=== (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.3 Example 3 ~-~- Connect to SIL-400 === 861 861 871 +==== 2.6.3.1 Reference Manual and Command ==== 862 862 873 + 874 +* [[SIL-400 Product Page>>https://www.apogeeinstruments.com/sil-411-commercial-grade-sdi-12-digital-output-standard-field-of-view-infrared-radiometer-sensor/]] 875 + 876 +* Commands to be used in PC and output. 877 + 878 +~1. check device address 879 + 880 +2. change device address 881 + 882 +3. check device ID 883 + 884 +4. start measure 885 + 886 +5. Get Meausre result 887 + 888 +[[image:image-20230603121606-7.png||height="242" width="307"]] 889 + 890 + 891 +==== 2.6.3.2 Hardware Connection to SDI-12-LB ==== 892 + 893 + 894 +[[image:image-20230603121643-8.png||height="442" width="656"]] 895 + 896 + 897 +==== 2.6.3.3 Commands set in SDI-12-LB and uplink payload ==== 898 + 899 + 900 +[[image:image-20230603121721-9.png]] 901 + 902 +[[image:image-20230603121752-10.png]] 903 + 904 +Data in TTN: 905 + 906 +[[image:image-20230603121826-11.png||height="155" width="1104"]] 907 + 908 + 909 + 910 +=== (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.4 Example 4 ~-~- Connect to TEROS-12 === 911 + 912 + 913 +==== 2.6.4.1 Reference Manual and Command ==== 914 + 915 + 916 +* [[TEROS-12 Product Page>>https://www.metergroup.com/en/meter-environment/products/teros-12-soil-moisture-sensor]] 917 + 918 +* Commands to be used in PC and output. 919 + 920 +1.check device address 921 + 922 +2.change device address 923 + 924 +3.check device ID 925 + 926 +4.start measure 927 + 928 +5.Get Meausre result 929 + 930 +[[image:image-20230603122248-16.png||height="196" width="198"]] 931 + 932 + 933 +==== 2.6.4.2 Hardware Connection to SDI-12-LB ==== 934 + 935 + 936 +[[image:image-20230603122212-15.png||height="502" width="667"]] 937 + 938 + 939 +==== 2.6.4.3 Commands set in SDI-12-LB and uplink payload ==== 940 + 941 +[[image:image-20230603122040-12.png]] 942 + 943 +[[image:image-20230603122109-13.png||height="469" width="762"]] 944 + 945 + 946 +**Data in TTN:** 947 + 948 +[[image:image-20230603122139-14.png||height="148" width="1128"]] 949 + 950 + 951 +=== (% id="cke_bm_1489640S" style="display:none" %) (% id="cke_bm_1172015S" style="display:none" %) (%%)2.6.5 Example 5 ~-~- Connect to SIL-400/TEROS-12 & Hygrovue10 === 952 + 953 +==== 2.6.5.1 Important Notice! ==== 954 + 955 + 956 +* The product page and reference command see above example 2,3,4 957 + 958 +* All of these SDI-12 sensors use the same address (address 0) by default. So we need to change their address to different address, by using **aAb!** command. See above example. 959 + 960 +* The sensor needs to be powered to a steady statue. So the 12VT time need to be set to the maximum stable time for the sensors. in this example, it is 13 seconds. 961 + 962 +* If these SDI-12 sensors are powered by external power source. It will add 300uA in the total current in SDI-12-LB. 963 + 964 + 965 + 966 +==== 2.6.5.2 Hardware Connection to SDI-12-LB ==== 967 + 968 + 969 +[[image:image-20230603122508-17.png||height="526" width="742"]] 970 + 971 + 972 +==== 2.6.5.3 Commands set in SDI-12-LB and uplink payload ==== 973 + 974 + 975 +[[image:image-20230603122549-18.png]] 976 + 977 +[[image:image-20230603122623-19.png||height="483" width="1121"]] 978 + 979 + 980 +**Data in TTN:** 981 + 982 +[[image:image-20230603122719-20.png||height="151" width="1179"]] 983 + 984 + 863 863 == 2.7 Frequency Plans == 864 864 865 865 ... ... @@ -933,6 +933,7 @@ 933 933 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 934 934 935 935 1058 + 936 936 == 3.2 Set Interrupt Mode == 937 937 938 938 ... ... @@ -965,6 +965,7 @@ 965 965 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 966 966 967 967 1091 + 968 968 == 3.3 Set the output time == 969 969 970 970 ... ... @@ -1035,6 +1035,7 @@ 1035 1035 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 1036 1036 1037 1037 1162 + 1038 1038 == 3.4 Set the all data mode == 1039 1039 1040 1040 ... ... @@ -1058,6 +1058,7 @@ 1058 1058 * Example 2: Downlink Payload: AB 01 ~/~/ AT+ALLDATAMOD=1 1059 1059 1060 1060 1186 + 1061 1061 == 3.5 Set the splicing payload for uplink == 1062 1062 1063 1063 ... ... @@ -1115,6 +1115,7 @@ 1115 1115 * Example 2: Downlink Payload: AE 05 ~/~/ AT+PAYVER=5 1116 1116 1117 1117 1244 + 1118 1118 = 4. Battery & Power Consumption = 1119 1119 1120 1120 ... ... @@ -1202,6 +1202,7 @@ 1202 1202 * Weight / pcs : g 1203 1203 1204 1204 1332 + 1205 1205 = 10. Support = 1206 1206 1207 1207
- image-20230603122549-18.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +90.9 KB - Content
- image-20230603122623-19.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +139.5 KB - Content
- image-20230603122719-20.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +83.8 KB - Content