<
From version < 55.1 >
edited by Edwin Chen
on 2023/06/03 12:12
To version < 56.1 >
edited by Edwin Chen
on 2023/06/03 12:12
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -66,7 +66,6 @@
66 66  * 8500mAh Battery for long term use
67 67  
68 68  
69 -
70 70  == 1.3 Specification ==
71 71  
72 72  
... ... @@ -116,7 +116,6 @@
116 116  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
117 117  
118 118  
119 -
120 120  == 1.4 Connect to SDI-12 Sensor ==
121 121  
122 122  
... ... @@ -152,7 +152,6 @@
152 152  |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode.
153 153  
154 154  
155 -
156 156  == 1.7 Pin Mapping ==
157 157  
158 158  
... ... @@ -757,9 +757,9 @@
757 757  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]
758 758  
759 759  
760 -== 2.6 Examples To Set SDI commands. ==
757 +== 2.6 Examples To Set SDI commands ==
761 761  
762 -=== 2.6.1 Examples 1 ===
759 +=== 2.6.1 Examples 1 ~-~- General Example ===
763 763  
764 764  
765 765  COM port and SDI-12 sensor communication converted to SDI-12-LB and SDI-12 sensor communication.
... ... @@ -825,6 +825,44 @@
825 825  Partial cut, the cut sensor address and the first two parameters:(% style="color:#037691" %)**AT+DATACUTx=25,2,1~~12, cut out the character field ” 4+30.8+22.84”**.
826 826  
827 827  
825 +=== 2.6.2 Example ~-~- Connect to Hygrovue10 ===
826 +
827 +==== 2.6.2.1 Reference Manual and Command ====
828 +
829 +* [[Hygrovue10 Product Page>>https://www.campbellsci.com/hygrovue10]]
830 +* Commands to be used in PC and output.
831 +
832 +1.check device address
833 +
834 +2.change device address
835 +
836 +3.check device ID
837 +
838 +4.start measure
839 +
840 +5.Get Meausre result
841 +
842 +[[image:image-20230603120209-2.png||height="281" width="267"]]
843 +
844 +
845 +==== 2.6.2.2 Hardware Connection to SDI-12-LB ====
846 +
847 +[[image:image-20230603120515-3.png]]
848 +
849 +
850 +==== 2.6.2.3 Commands set in SDI-12-LB and uplink payload ====
851 +
852 +[[image:image-20230603120648-4.png]]
853 +
854 +[[image:image-20230603120726-5.png]]
855 +
856 +Data in TTN:
857 +
858 +[[image:image-20230603120859-6.png||height="118" width="1285"]]
859 +
860 +
861 +
862 +
828 828  == 2.7 Frequency Plans ==
829 829  
830 830  
... ... @@ -898,7 +898,6 @@
898 898  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
899 899  
900 900  
901 -
902 902  == 3.2 Set Interrupt Mode ==
903 903  
904 904  
... ... @@ -931,7 +931,6 @@
931 931  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
932 932  
933 933  
934 -
935 935  == 3.3 Set the output time ==
936 936  
937 937  
... ... @@ -1002,7 +1002,6 @@
1002 1002  * Example 6: Downlink Payload: 07030000  **~-~-->**  AT+12VT=0
1003 1003  
1004 1004  
1005 -
1006 1006  == 3.4 Set the all data mode ==
1007 1007  
1008 1008  
... ... @@ -1026,7 +1026,6 @@
1026 1026  * Example 2: Downlink Payload: AB 01  ~/~/  AT+ALLDATAMOD=1
1027 1027  
1028 1028  
1029 -
1030 1030  == 3.5 Set the splicing payload for uplink ==
1031 1031  
1032 1032  
... ... @@ -1084,7 +1084,6 @@
1084 1084  * Example 2: Downlink Payload: AE 05  ~/~/  AT+PAYVER=5
1085 1085  
1086 1086  
1087 -
1088 1088  = 4. Battery & Power Consumption =
1089 1089  
1090 1090  
... ... @@ -1172,7 +1172,6 @@
1172 1172  * Weight / pcs : g
1173 1173  
1174 1174  
1175 -
1176 1176  = 10. ​Support =
1177 1177  
1178 1178  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0