Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Xiaoling on 2025/04/25 08:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1007,13 +1007,13 @@ 1007 1007 1008 1008 (% style="color:blue" %)**AT Command: AT+ALLDATAMOD** 1009 1009 1010 -(% border="1" cellspacing="4" style=" background-color:#f7faff;width:437px" %)1011 -|=**Command Example**|=**Function**|=**Response** 1012 -|AT+ALLDATAMOD=?|Show current all data mode|((( 1010 +(% border="1" cellspacing="4" style="width:437px" %) 1011 +|=(% style="background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**Response** 1012 +|(% style="background-color:#F2F2F2" %)AT+ALLDATAMOD=?|(% style="background-color:#F2F2F2" %)Show current all data mode|(% style="background-color:#F2F2F2" %)((( 1013 1013 0 1014 1014 OK 1015 1015 ))) 1016 -|AT+ALLDATAMOD=1|Set all data mode is 1.|OK 1016 +|(% style="background-color:#F2F2F2" %)AT+ALLDATAMOD=1|(% style="background-color:#F2F2F2" %)Set all data mode is 1.|(% style="background-color:#F2F2F2" %)OK 1017 1017 1018 1018 (% style="color:blue" %)**Downlink Command: 0xAB** 1019 1019 ... ... @@ -1030,21 +1030,21 @@ 1030 1030 1031 1031 (% style="color:blue" %)**AT Command: AT+DATAUP** 1032 1032 1033 -(% border="1" cellspacing="4" style=" background-color:#f7faff;width:510px" %)1034 -|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 266px;" %)**Function**|=**Response** 1035 -|(% style="width:154px" %)AT+DATAUP =?|(% style="width:266px" %)Show current splicing payload for uplink mode|((( 1033 +(% border="1" cellspacing="4" style="width:510px" %) 1034 +|=(% style="width: 154px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 266px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**Response** 1035 +|(% style="width:154px;background-color:#F2F2F2" %)AT+DATAUP =?|(% style="width:266px;background-color:#F2F2F2" %)Show current splicing payload for uplink mode|(% style="background-color:#F2F2F2" %)((( 1036 1036 0 1037 1037 OK 1038 1038 ))) 1039 -|(% style="width:154px" %)AT+DATAUP =0|(% style="width:266px" %)((( 1039 +|(% style="width:154px;background-color:#F2F2F2" %)AT+DATAUP =0|(% style="width:266px;background-color:#F2F2F2" %)((( 1040 1040 Set splicing payload for uplink mode is 0. 1041 -)))|((( 1041 +)))|(% style="background-color:#F2F2F2" %)((( 1042 1042 OK 1043 1043 ))) 1044 -|(% style="width:154px" %)AT+DATAUP =1|(% style="width:266px" %)Set splicing payload for uplink mode is 1 , and the each splice uplink is sent sequentially.|OK 1045 -|(% style="width:154px" %)AT+DATAUP =1,20000|(% style="width:266px" %)((( 1044 +|(% style="width:154px;background-color:#F2F2F2" %)AT+DATAUP =1|(% style="width:266px;background-color:#F2F2F2" %)Set splicing payload for uplink mode is 1 , and the each splice uplink is sent sequentially.|(% style="background-color:#F2F2F2" %)OK 1045 +|(% style="width:154px;background-color:#F2F2F2" %)AT+DATAUP =1,20000|(% style="width:266px;background-color:#F2F2F2" %)((( 1046 1046 Set splicing payload for uplink mode is 1, and the uplink interval of each splice to 20000 milliseconds. 1047 -)))|OK 1047 +)))|(% style="background-color:#F2F2F2" %)OK 1048 1048 1049 1049 (% style="color:blue" %)**Downlink Command: 0xAD** 1050 1050 ... ... @@ -1064,13 +1064,13 @@ 1064 1064 1065 1065 (% style="color:blue" %)**AT Command: AT+PAYVER** 1066 1066 1067 -(% border="1" cellspacing="4" style=" background-color:#f7faff;width:437px" %)1068 -|=(% style="width: 158px;" %)**Command Example**|=(% style="width: 192px;" %)**Function**|=**Response** 1069 -|(% style="width:158px" %)AT+PAYVER=?|(% style="width:192px" %)Show current payload version|((( 1067 +(% border="1" cellspacing="4" style="width:437px" %) 1068 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 192px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**Response** 1069 +|(% style="width:158px;background-color:#F2F2F2" %)AT+PAYVER=?|(% style="width:192px;background-color:#F2F2F2" %)Show current payload version|(% style="background-color:#F2F2F2" %)((( 1070 1070 1 1071 1071 OK 1072 1072 ))) 1073 -|(% style="width:158px" %)AT+PAYVER=5|(% style="width:192px" %)Set payload version is 5.|OK 1073 +|(% style="width:158px;background-color:#F2F2F2" %)AT+PAYVER=5|(% style="width:192px;background-color:#F2F2F2" %)Set payload version is 5.|(% style="background-color:#F2F2F2" %)OK 1074 1074 1075 1075 (% style="color:blue" %)**Downlink Command: 0xAE** 1076 1076 ... ... @@ -1080,76 +1080,13 @@ 1080 1080 * Example 2: Downlink Payload: AE 05 ~/~/ AT+PAYVER=5 1081 1081 1082 1082 1083 -= 4. Battery & how toreplace=1083 += 4. Battery & Power Consumption = 1084 1084 1085 - ==4.1BatteryType==1085 +PS-LB-NA uses ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 1086 1086 1087 + [[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 1087 1087 1088 -SDI-12-LB is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>https://www.dropbox.com/sh/w9l2oa3ytpculph/AAAPtt-apH4lYfCj-2Y6lHvQa?dl=0]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 1089 1089 1090 - 1091 -The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance. 1092 - 1093 -[[image:1675234124233-857.png||_mstalt="295035"]] 1094 - 1095 - 1096 -Minimum Working Voltage for the SDI-12-LB: 1097 - 1098 -SDI-12-LB: 2.45v ~~ 3.6v 1099 - 1100 - 1101 -== 4.2 Replace Battery == 1102 - 1103 - 1104 -Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. 1105 - 1106 -And make sure the positive and negative pins match. 1107 - 1108 - 1109 -== 4.3 Power Consumption Analyze == 1110 - 1111 - 1112 -Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 1113 - 1114 -Instruction to use as below: 1115 - 1116 -(% style="color:blue" %)**Step 1:**(%%) Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0>>https://www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0]] 1117 - 1118 -(% style="color:blue" %)**Step 2:**(%%) Open it and choose 1119 - 1120 -* Product Model 1121 -* Uplink Interval 1122 -* Working Mode 1123 - 1124 -And the Life expectation in difference case will be shown on the right. 1125 - 1126 - 1127 -[[image:1675234155374-163.png||_mstalt="294411"]] 1128 - 1129 - 1130 -The battery related documents as below: 1131 - 1132 -* [[Battery Dimension>>https://www.dropbox.com/s/ox5g9njwjle7aw3/LSN50-Battery-Dimension.pdf?dl=0]], 1133 -* [[Lithium-Thionyl Chloride Battery datasheet, Tech Spec>>https://www.dropbox.com/sh/d4oyfnp8o94180o/AABQewCNSh5GPeQH86UxRgQQa?dl=0]] 1134 -* [[Lithium-ion Battery-Capacitor datasheet>>https://www.dropbox.com/s/791gjes2lcbfi1p/SPC_1520_datasheet.jpg?dl=0]], [[Tech Spec>>https://www.dropbox.com/s/4pkepr9qqqvtzf2/SPC1520%20Technical%20Specification20171123.pdf?dl=0]] 1135 - 1136 -[[image:image-20230201145019-19.png||_mstalt="453947"]] 1137 - 1138 - 1139 -=== 4.3.1 Battery Note === 1140 - 1141 - 1142 -The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 1143 - 1144 - 1145 -=== 4.3.2 Replace the battery === 1146 - 1147 - 1148 -You can change the battery in the SDI-12-LB.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board. 1149 - 1150 -The default battery pack of SDI-12-LB includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 1151 - 1152 - 1153 1153 = 5. Remote Configure device = 1154 1154 1155 1155 == 5.1 Connect via BLE ==