From version < 48.9 >
edited by Xiaoling
on 2023/04/03 11:39
To version < 48.10 >
edited by Xiaoling
on 2023/04/03 11:44
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -65,7 +65,6 @@
65 65  * Downlink to change configure
66 66  * 8500mAh Battery for long term use
67 67  
68 -
69 69  == 1.3 Specification ==
70 70  
71 71  
... ... @@ -114,7 +114,6 @@
114 114  * Sleep Mode: 5uA @ 3.3v
115 115  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
116 116  
117 -
118 118  == 1.4 Connect to SDI-12 Sensor ==
119 119  
120 120  
... ... @@ -149,7 +149,6 @@
149 149  )))
150 150  |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode.
151 151  
152 -
153 153  == 1.7 Pin Mapping ==
154 154  
155 155  
... ... @@ -483,8 +483,8 @@
483 483  (% style="color:blue" %)**AT+DATACUTx**(%%) : This command defines how to handle the return from AT+COMMANDx, max return length is 100 bytes.
484 484  
485 485  (% border="1" style="width:436px" %)
486 -|(% style="width:433px;background-color:#F2F2F2 %)(((
487 -**(% style="color:#0070C0" %)AT+DATACUTx=a,b,c**
483 +|(% style="background-color:#f2f2f2; width:433px" %)(((
484 +(% style="color:#0070c0" %)**AT+DATACUTx=a,b,c**
488 488  
489 489  **a**:  length for the return of AT+COMMAND
490 490  
... ... @@ -498,9 +498,9 @@
498 498  
499 499  (% border="1" cellspacing="4" style="width:510px" %)
500 500  |=(% style="width: 164px;background-color:#D9E2F3;color:#0070C0" %)**AT+DATACUT1 value**|=(% style="width: 344px;background-color:#D9E2F3;color:#0070C0" %)**Final Result to combine Payload**
501 -|(% style="width:164px;background-color:#F2F2F2" %)34,1,1+2+3|(% style="width:344px;background-color:#F2F2F2" %)0D 00 01 30 31 33
502 -|(% style="width:164px;background-color:#F2F2F2" %)34,2,1~~8+12~~16|(% style="width:344px;background-color:#F2F2F2" %)0D 00 01 30 31 33 4D 45 54 45 52 54 45 52 31 32
503 -|(% style="width:164px;background-color:#F2F2F2" %)34,2,1~~34|(% style="width:344px;background-color:#F2F2F2" %)0D 00 01 30 31 33 4D 45 54 45 52 20 20 20 54 45 52 31 32 20 31 31 32 54 31 32 2D 30 30 30 32 34 38 39 35 0D 0A
498 +|(% style="background-color:#f2f2f2; width:164px" %)34,1,1+2+3|(% style="background-color:#f2f2f2; width:344px" %)0D 00 01 30 31 33
499 +|(% style="background-color:#f2f2f2; width:164px" %)34,2,1~~8+12~~16|(% style="background-color:#f2f2f2; width:344px" %)0D 00 01 30 31 33 4D 45 54 45 52 54 45 52 31 32
500 +|(% style="background-color:#f2f2f2; width:164px" %)34,2,1~~34|(% style="background-color:#f2f2f2; width:344px" %)0D 00 01 30 31 33 4D 45 54 45 52 20 20 20 54 45 52 31 32 20 31 31 32 54 31 32 2D 30 30 30 32 34 38 39 35 0D 0A
504 504  
505 505  * (% style="color:blue" %)** Downlink Payload:**
506 506  
... ... @@ -689,7 +689,7 @@
689 689  
690 690  * Periodically Uplink: FPORT=2
691 691  
692 -(% border="1" cellspacing="4" style="background-color:#F2F2F2; width:500px" %)
689 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %)
693 693  |=(% style="width: 90px;" %)(((
694 694  **Size(bytes)**
695 695  )))|=(% style="width: 80px;" %)**2**|=(% style="width: 90px;" %)**1**|=(% style="width: 240px;" %)**Length depends on the return from the commands**
... ... @@ -883,7 +883,6 @@
883 883  Set transmit interval to 60000ms = 60 seconds
884 884  )))
885 885  
886 -
887 887  (% style="color:blue" %)**Downlink Command: 0x01**
888 888  
889 889  
... ... @@ -894,7 +894,6 @@
894 894  * Example 1: Downlink Payload: 0100001E  ~/~/ Set Transmit Interval (TDC) = 30 seconds
895 895  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
896 896  
897 -
898 898  == 3.2 Set Interrupt Mode ==
899 899  
900 900  
... ... @@ -917,7 +917,6 @@
917 917  3. (Trigger by rising edge)
918 918  )))|(% style="background-color:#f2f2f2; width:157px" %)OK
919 919  
920 -
921 921  (% style="color:blue" %)**Downlink Command: 0x06**
922 922  
923 923  Format: Command Code (0x06) followed by 3 bytes.
... ... @@ -927,7 +927,6 @@
927 927  * Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
928 928  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
929 929  
930 -
931 931  == 3.3 Set the output time ==
932 932  
933 933  
... ... @@ -952,7 +952,6 @@
952 952  OK
953 953  )))
954 954  
955 -
956 956  (% style="color:blue" %)**AT Command: AT+5VT**
957 957  
958 958  (% border="1" cellspacing="4" style="width:470px" %)
... ... @@ -972,7 +972,6 @@
972 972  OK
973 973  )))
974 974  
975 -
976 976  (% style="color:blue" %)**AT Command: AT+12VT**
977 977  
978 978  (% border="1" cellspacing="4" style="width:443px" %)
... ... @@ -999,7 +999,6 @@
999 999  * Example 5: Downlink Payload: 070301F4  **~-~-->**  AT+12VT=500
1000 1000  * Example 6: Downlink Payload: 07030000  **~-~-->**  AT+12VT=0
1001 1001  
1002 -
1003 1003  == 3.4 Set the all data mode ==
1004 1004  
1005 1005  
... ... @@ -1022,7 +1022,6 @@
1022 1022  * Example 1: Downlink Payload: AB 00  ~/~/  AT+ALLDATAMOD=0
1023 1023  * Example 2: Downlink Payload: AB 01  ~/~/  AT+ALLDATAMOD=1
1024 1024  
1025 -
1026 1026  == 3.5 Set the splicing payload for uplink ==
1027 1027  
1028 1028  
... ... @@ -1079,7 +1079,6 @@
1079 1079  * Example 1: Downlink Payload: AE 01  ~/~/  AT+PAYVER=1
1080 1080  * Example 2: Downlink Payload: AE 05  ~/~/  AT+PAYVER=5
1081 1081  
1082 -
1083 1083  = 4. Battery & how to replace =
1084 1084  
1085 1085  == 4.1 Battery Type ==
... ... @@ -1229,7 +1229,6 @@
1229 1229  * Package Size / pcs : cm
1230 1230  * Weight / pcs : g
1231 1231  
1232 -
1233 1233  = 10. ​Support =
1234 1234  
1235 1235  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0