... ... @@ -65,8 +65,6 @@
65 65  * Downlink to change configure
66 66  * 8500mAh Battery for long term use
67 67  
68 -
69 -
70 70  == 1.3 Specification ==
71 71  
72 72  
... ... @@ -115,8 +115,6 @@
115 115  * Sleep Mode: 5uA @ 3.3v
116 116  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
117 117  
118 -
119 -
120 120  == 1.4 Connect to SDI-12 Sensor ==
121 121  
122 122  
... ... @@ -151,8 +151,6 @@
151 151  )))
152 152  |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode.
153 153  
154 -
155 -
156 156  == 1.7 Pin Mapping ==
157 157  
158 158  
... ... @@ -896,8 +896,6 @@
896 896  * Example 1: Downlink Payload: 0100001E  ~/~/ Set Transmit Interval (TDC) = 30 seconds
897 897  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
898 898  
899 -
900 -
901 901  == 3.2 Set Interrupt Mode ==
902 902  
903 903  
... ... @@ -929,8 +929,6 @@
929 929  * Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
930 930  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
931 931  
932 -
933 -
934 934  == 3.3 Set the output time ==
935 935  
936 936  
... ... @@ -955,7 +955,6 @@
955 955  OK
956 956  )))
957 957  
958 -
959 959  (% style="color:blue" %)**AT Command: AT+5VT**
960 960  
961 961  (% border="1" cellspacing="4" style="width:470px" %)
... ... @@ -975,7 +975,6 @@
975 975  OK
976 976  )))
977 977  
978 -
979 979  (% style="color:blue" %)**AT Command: AT+12VT**
980 980  
981 981  (% border="1" cellspacing="4" style="width:443px" %)
... ... @@ -1002,8 +1002,6 @@
1002 1002  * Example 5: Downlink Payload: 070301F4  **~-~-->**  AT+12VT=500
1003 1003  * Example 6: Downlink Payload: 07030000  **~-~-->**  AT+12VT=0
1004 1004  
1005 -
1006 -
1007 1007  == 3.4 Set the all data mode ==
1008 1008  
1009 1009  
... ... @@ -1026,8 +1026,6 @@
1026 1026  * Example 1: Downlink Payload: AB 00  ~/~/  AT+ALLDATAMOD=0
1027 1027  * Example 2: Downlink Payload: AB 01  ~/~/  AT+ALLDATAMOD=1
1028 1028  
1029 -
1030 -
1031 1031  == 3.5 Set the splicing payload for uplink ==
1032 1032  
1033 1033  
... ... @@ -1084,16 +1084,76 @@
1084 1084  * Example 1: Downlink Payload: AE 01  ~/~/  AT+PAYVER=1
1085 1085  * Example 2: Downlink Payload: AE 05  ~/~/  AT+PAYVER=5
1086 1086  
1071 += 4. Battery & how to replace =
1087 1087  
1073 +== 4.1 Battery Type ==
1088 1088  
1089 -= 4. Battery & Power Consumption =
1090 1090  
1076 +SDI-12-LB is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>https://www.dropbox.com/sh/w9l2oa3ytpculph/AAAPtt-apH4lYfCj-2Y6lHvQa?dl=0]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
1091 1091  
1092 -SDI-12-LB uses ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
1093 1093  
1094 -[[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
1079 +The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
1095 1095  
1081 +[[image:1675234124233-857.png||_mstalt="295035"]]
1096 1096  
1083 +
1084 +Minimum Working Voltage for the SDI-12-LB:
1085 +
1086 +SDI-12-LB:  2.45v ~~ 3.6v
1087 +
1088 +
1089 +== 4.2 Replace Battery ==
1090 +
1091 +
1092 +Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
1093 +
1094 +And make sure the positive and negative pins match.
1095 +
1096 +
1097 +== 4.3 Power Consumption Analyze ==
1098 +
1099 +
1100 +Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
1101 +
1102 +Instruction to use as below:
1103 +
1104 +(% style="color:blue" %)**Step 1:**(%%) Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0>>https://www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0]]
1105 +
1106 +(% style="color:blue" %)**Step 2:**(%%) Open it and choose
1107 +
1108 +* Product Model
1109 +* Uplink Interval
1110 +* Working Mode
1111 +
1112 +And the Life expectation in difference case will be shown on the right.
1113 +
1114 +
1115 +[[image:1675234155374-163.png||_mstalt="294411"]]
1116 +
1117 +
1118 +The battery related documents as below:
1119 +
1120 +* [[Battery Dimension>>https://www.dropbox.com/s/ox5g9njwjle7aw3/LSN50-Battery-Dimension.pdf?dl=0]],
1121 +* [[Lithium-Thionyl Chloride Battery datasheet, Tech Spec>>https://www.dropbox.com/sh/d4oyfnp8o94180o/AABQewCNSh5GPeQH86UxRgQQa?dl=0]]
1122 +* [[Lithium-ion Battery-Capacitor datasheet>>https://www.dropbox.com/s/791gjes2lcbfi1p/SPC_1520_datasheet.jpg?dl=0]], [[Tech Spec>>https://www.dropbox.com/s/4pkepr9qqqvtzf2/SPC1520%20Technical%20Specification20171123.pdf?dl=0]]
1123 +
1124 +[[image:image-20230201145019-19.png||_mstalt="453947"]]
1125 +
1126 +
1127 +=== 4.3.1 ​Battery Note ===
1128 +
1129 +
1130 +The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
1131 +
1132 +
1133 +=== 4.3.2 Replace the battery ===
1134 +
1135 +
1136 +You can change the battery in the SDI-12-LB.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
1137 +
1138 +The default battery pack of SDI-12-LB includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1139 +
1140 +
1097 1097  = 5. Remote Configure device =
1098 1098  
1099 1099  == 5.1 Connect via BLE ==
... ... @@ -1173,8 +1173,6 @@
1173 1173  * Package Size / pcs : cm
1174 1174  * Weight / pcs : g
1175 1175  
1176 -
1177 -
1178 1178  = 10. ​Support =
1179 1179  
1180 1180  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0