... ... @@ -77,8 +77,6 @@
77 77  (% style="color:#037691" %)**Common DC Characteristics:**
78 78  
79 79  * Supply Voltage: 2.5v ~~ 3.6v
80 -* Support current: 5V 300mA
81 - 12V 100mA
82 82  * Operating Temperature: -40 ~~ 85°C
83 83  
84 84  (% style="color:#037691" %)**LoRa Spec:**
... ... @@ -747,7 +747,7 @@
747 747  
748 748  The SDI-12-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link:
749 749  
750 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]
748 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]]]
751 751  
752 752  
753 753  == 2.6 Examples To Set SDI commands. ==
... ... @@ -754,69 +754,68 @@
754 754  
755 755  === 2.6.1 Examples 1 ===
756 756  
757 -
758 758  COM port and SDI-12 sensor communication converted to SDI-12-LB and SDI-12 sensor communication.
759 759  
760 760  [[image:image-20230222143809-1.png||height="564" width="729"]]
761 761  
759 +1)The AT+COMMANDx command is applied to the red arrow part, and sends the SDI12 command to the SDI12 sensor:
762 762  
763 -(% style="color:blue" %)**1) The AT+COMMANDx command is applied to the red arrow part, and sends the SDI12 command to the SDI12 sensor:**
761 +a.Send the first command and get the first reply:
764 764  
765 -a. Send the first command and get the first reply:
763 +AT+COMMANDx=1I!,0,0,1
766 766  
767 -(% style="color:#037691" %)**AT+COMMANDx=1I!,0,0,1**
765 +b.Send the second command and get the second reply:
768 768  
769 -b. Send the second command and get the second reply:
767 +AT+COMMANDx=2I!,0,0,1
770 770  
771 -(% style="color:#037691" %)**AT+COMMANDx=2I!,0,0,1**
769 +c.Send the third command and get the third reply:
772 772  
773 -c. Send the third command and get the third reply:
771 +AT+COMMANDx=3I!,0,0,1
774 774  
775 -(% style="color:#037691" %)**AT+COMMANDx=3I!,0,0,1**
773 +d.Send the fourth command and get the fourth reply:
776 776  
777 -d. Send the fourth command and get the fourth reply:
775 +AT+COMMANDx=4I!,0,0,1
778 778  
779 -(% style="color:#037691" %)**AT+COMMANDx=4I!,0,0,1**
777 +e.Send the fifth command plus the sixth command, get the sixth reply:
780 780  
781 -e. Send the fifth command plus the sixth command, get the sixth reply:
779 +AT+COMMANDx=1M!,2,1,1
782 782  
783 -(% style="color:#037691" %)**AT+COMMANDx=1M!,2,1,1**
781 +f.Send the seventh command plus the eighth command, get the eighth reply:
784 784  
785 -f. Send the seventh command plus the eighth command, get the eighth reply:
783 +AT+COMMANDx=2M!,2,1,1
786 786  
787 -(% style="color:#037691" %)**AT+COMMANDx=2M!,2,1,1**
785 +g.Send the ninth command plus the tenth command, get the tenth reply:
788 788  
789 -g. Send the ninth command plus the tenth command, get the tenth reply:
787 +AT+COMMANDx=3M!,1,1,1
790 790  
791 -(% style="color:#037691" %)**AT+COMMANDx=3M!,1,1,1**
789 +h.Send the eleventh command plus the twelfth command, get the twelfth reply:
792 792  
793 -h. Send the eleventh command plus the twelfth command, get the twelfth reply:
791 +AT+COMMANDx=4M!,1,1,1
794 794  
795 -(% style="color:#037691" %)**AT+COMMANDx=4M!,1,1,1**
796 796  
794 +2) The AT+DATACUTx command is applied to the green arrow part, receiving and cut out data from the SDI12 sensor:
797 797  
798 -(% style="color:blue" %)**2) The AT+DATACUTx command is applied to the green arrow part, receiving and cut out data from the SDI12 sensor:**
796 +a.The first reply, all 34 characters: ”113TRUEBNERSMT100038220303182331<CR><LF>”
799 799  
800 -a. The first reply, all 34 characters: ”113TRUEBNERSMT100038220303182331<CR><LF>”
798 +Cut out all characters: AT+ALLDATAMOD=1 or AT+DATACUTx=34,2,1~~34;
801 801  
802 -Cut out all characters: (% style="color:#037691" %)**AT+ALLDATAMOD=1 or AT+DATACUTx=34,2,1~~34**;
803 -
804 804  b. The sixth reply, all 31 characters:”1+19210+1.04+0.00+22.49+11.75<CR><LF>”
805 805  
806 -Cut out all characters: (% style="color:#037691" %)**AT+ALLDATAMOD=1 or AT+DATACUTx=31,2,1~~31**;
802 +Cut out all characters: AT+ALLDATAMOD=1 or AT+DATACUTx=31,2,1~~31;
807 807  
808 808  c. The eighth reply, all 31 characters:”2+18990+1.08+0.00+22.24+11.80<CR><LF>”
809 809  
810 -Cut out all characters: (% style="color:#037691" %)**AT+ALLDATAMOD=1 or AT+DATACUTx=31,2,1~~31**;
806 +Cut out all characters: AT+ALLDATAMOD=1 or AT+DATACUTx=31,2,1~~31;
811 811  
812 812  d. The tenth reply, all 15 characters:”3-2919.8+24.0<CR><LF>”
813 813  
814 -Cut out all characters: (% style="color:#037691" %)**AT+ALLDATAMOD=1 or AT+DATACUTx=15,2,1~~15**;
810 +Cut out all characters: AT+ALLDATAMOD=1 or AT+DATACUTx=15,2,1~~15;
815 815  
816 816  e. The twelfth reply, all 25 characters:”4+30.8+22.84+4.7+954.38<CR><LF>”
817 817  
818 -Partial cut, the cut sensor address and the first two parameters:(% style="color:#037691" %)**AT+DATACUTx=25,2,1~~12, cut out the character field ” 4+30.8+22.84”**.
814 +Partial cut, the cut sensor address and the first two parameters:AT+DATACUTx=25,2,1~~12, cut out the character field ” 4+30.8+22.84”.
819 819  
816 +== ==
820 820  