Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Mengting Qiu on 2025/07/03 15:42
From version 46.1
edited by Bei Jinggeng
on 2023/03/20 10:20
on 2023/03/20 10:20
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 6 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.Xiaoling - Content
-
... ... @@ -3,7 +3,6 @@ 3 3 4 4 **Table of Contents:** 5 5 6 -{{toc/}} 7 7 8 8 9 9 ... ... @@ -22,40 +22,32 @@ 22 22 == 1.1 What is SDI-12 to LoRaWAN Converter == 23 23 24 24 25 -((( 26 -The Dragino (% style="color:blue" %)**SDI-12-LB**(%%) is a (% style="color:blue" %)**SDI-12 to LoRaWAN Converter **(%%)designed for Smart Agriculture solution. 27 -))) 24 +The Dragino **SDI-12-LB** is a **SDI-12 to LoRaWAN Converter **designed for Smart Agriculture solution. 28 28 29 -((( 30 30 SDI-12 (Serial Digital Interface at 1200 baud) is an asynchronous [[serial communications>>url:https://en.wikipedia.org/wiki/Serial_communication]] protocol for intelligent sensors that monitor environment data. SDI-12 protocol is widely used in Agriculture sensor and Weather Station sensors. 31 -))) 32 32 33 -((( 34 -SDI-12-LB has SDI-12 interface and support 12v output to power external SDI-12 sensor. It can get the environment data from SDI-12 sensor and sends out the data via LoRaWAN wireless protocol. 35 -))) 28 +**SDI-12-LB** has SDI-12 interface and support 12v output to power external SDI-12 sensor. It can get the environment data from SDI-12 sensor and sends out the data via LoRaWAN wireless protocol. 36 36 37 -((( 38 -The LoRa wireless technology used in SDI-12-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 39 -))) 30 +The LoRa wireless technology used in **SDI-12-LB** allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 40 40 41 -((( 42 -SDI-12-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 43 -))) 32 +**SDI-12-LB** is powered by **8500mAh Li-SOCI2 battery**, it is designed for long term use up to 5 years. 44 44 45 -((( 46 -Each SDI-12-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 47 -))) 34 +Each **SDI-12-LB** is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 48 48 49 49 50 50 [[image:image-20230201084414-1.png||height="464" width="1108"]] 51 51 52 52 40 + 41 + 42 + 43 + 53 53 == 1.2 Features == 54 54 55 55 56 56 * LoRaWAN 1.0.3 Class A 57 57 * Ultra-low power consumption 58 -* Controllable 3.3v,5v and 12v output to power external sensor49 +* Controllable 5v and 12v output to power external sensor 59 59 * SDI-12 Protocol to connect to SDI-12 Sensor 60 60 * Monitor Battery Level 61 61 * Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865 ... ... @@ -68,20 +68,18 @@ 68 68 == 1.3 Specification == 69 69 70 70 71 - (% style="color:#037691" %)**Micro Controller:**62 +**Micro Controller:** 72 72 73 73 * MCU: 48Mhz ARM 74 74 * Flash: 256KB 75 75 * RAM: 64KB 76 76 77 - (% style="color:#037691" %)**Common DC Characteristics:**68 +**Common DC Characteristics:** 78 78 79 79 * Supply Voltage: 2.5v ~~ 3.6v 80 -* Support current: 5V 300mA 81 - 12V 100mA 82 82 * Operating Temperature: -40 ~~ 85°C 83 83 84 - (% style="color:#037691" %)**LoRa Spec:**73 +**LoRa Spec:** 85 85 86 86 * Frequency Range, Band 1 (HF): 862 ~~ 1020 Mhz 87 87 * Max +22 dBm constant RF output vs. ... ... @@ -88,19 +88,19 @@ 88 88 * RX sensitivity: down to -139 dBm. 89 89 * Excellent blocking immunity 90 90 91 - (% style="color:#037691" %)**Current Input Measuring :**80 +**Current Input Measuring :** 92 92 93 93 * Range: 0 ~~ 20mA 94 94 * Accuracy: 0.02mA 95 95 * Resolution: 0.001mA 96 96 97 - (% style="color:#037691" %)**Voltage Input Measuring:**86 +**Voltage Input Measuring:** 98 98 99 99 * Range: 0 ~~ 30v 100 100 * Accuracy: 0.02v 101 101 * Resolution: 0.001v 102 102 103 - (% style="color:#037691" %)**Battery:**92 +**Battery:** 104 104 105 105 * Li/SOCI2 un-chargeable battery 106 106 * Capacity: 8500mAh ... ... @@ -108,7 +108,7 @@ 108 108 * Max continuously current: 130mA 109 109 * Max boost current: 2A, 1 second 110 110 111 - (% style="color:#037691" %)**Power Consumption**100 +**Power Consumption** 112 112 113 113 * Sleep Mode: 5uA @ 3.3v 114 114 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm ... ... @@ -123,9 +123,9 @@ 123 123 == 1.5 Sleep mode and working mode == 124 124 125 125 126 - (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life.115 +**Deep Sleep Mode: **Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life. 127 127 128 - (% style="color:blue" %)**Working Mode: **(%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode.117 +**Working Mode: **In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode. 129 129 130 130 131 131 == 1.6 Button & LEDs == ... ... @@ -134,18 +134,19 @@ 134 134 [[image:1675212633011-651.png]] 135 135 136 136 126 + 137 137 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 138 -|=(% style="width: 167px;" %)**Behavior on ACT**|=(% style="width: 1 09px;" %)**Function**|=(% style="width: 231px;" %)**Action**139 -|(% style="width:167px" %)Pressing ACT between 1s < time < 3s|(% style="width:1 09px" %)Send an uplink|(% style="width:231px" %)(((128 +|=(% style="width: 167px;" %)**Behavior on ACT**|=(% style="width: 117px;" %)**Function**|=(% style="width: 225px;" %)**Action** 129 +|(% style="width:167px" %)Pressing ACT between 1s < time < 3s|(% style="width:117px" %)Send an uplink|(% style="width:225px" %)((( 140 140 If sensor is already Joined to LoRaWAN network, sensor will send an uplink packet, (% style="color:blue" %)**blue led** (%%)will blink once. 141 141 Meanwhile, BLE module will be active and user can connect via BLE to configure device. 142 142 ))) 143 -|(% style="width:167px" %)Pressing ACT for more than 3s|(% style="width:1 09px" %)Active Device|(% style="width:231px" %)(((133 +|(% style="width:167px" %)Pressing ACT for more than 3s|(% style="width:117px" %)Active Device|(% style="width:225px" %)((( 144 144 (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:#037691" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. 145 145 (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 146 146 Once sensor is active, BLE module will be active and user can connect via BLE to configure device, no matter if device join or not join LoRaWAN network. 147 147 ))) 148 -|(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:1 09px" %)Deactivate Device|(% style="width:231px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means SDI-12-LB is in Deep Sleep Mode.138 +|(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode. 149 149 150 150 == 1.7 Pin Mapping == 151 151 ... ... @@ -170,6 +170,9 @@ 170 170 == 1.9 Mechanical == 171 171 172 172 163 + 164 + 165 + 173 173 [[image:image-20230201090139-2.png]] 174 174 175 175 [[image:image-20230201090139-3.png]] ... ... @@ -182,7 +182,7 @@ 182 182 == 2.1 How it works == 183 183 184 184 185 -The SDI-12-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%)mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and activate the SDI-12-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.178 +The SDI-12-LB is configured as **LoRaWAN OTAA Class A** mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and activate the SDI-12-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes. 186 186 187 187 188 188 == 2.2 Quick guide to connect to LoRaWAN server (OTAA) == ... ... @@ -197,47 +197,51 @@ 197 197 The LPS8V2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server. 198 198 199 199 200 - (% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from SDI-12-LB.193 +**Step 1**: Create a device in TTN with the OTAA keys from SDI-12-LB. 201 201 202 202 Each SDI-12-LB is shipped with a sticker with the default device EUI as below: 203 203 204 204 205 -[[image:image-20230 201152430-20.jpeg]]198 +[[image:image-20230131134744-2.jpeg]] 206 206 207 207 201 + 202 + 203 + 208 208 You can enter this key in the LoRaWAN Server portal. Below is TTN screen shot: 209 209 210 210 211 - (% style="color:blue" %)**Register the device**207 +**Register the device** 212 212 213 213 [[image:1675213652444-622.png]] 214 214 215 215 216 - (% style="color:blue" %)**Add APP EUI and DEV EUI**212 +**Add APP EUI and DEV EUI** 217 217 218 218 219 219 [[image:1675213661769-223.png]] 220 220 221 221 222 - (% style="color:blue" %)**Add APP EUI in the application**218 +**Add APP EUI in the application** 223 223 224 224 225 225 [[image:1675213675852-577.png]] 226 226 227 227 228 - (% style="color:blue" %)**Add APP KEY**224 +**Add APP KEY** 229 229 230 230 [[image:1675213686734-883.png]] 231 231 232 232 233 - (% style="color:blue" %)**Step 2**(%%): Activate on SDI-12-LB229 +**Step 2**: Activate on SDI-12-LB 234 234 235 235 236 236 Press the button for 5 seconds to activate the SDI-12-LB. 237 237 238 -(% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode** (%%)for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 239 239 235 +**Green led** will fast blink 5 times, device will enter **OTA mode** for 3 seconds. And then start to JOIN LoRaWAN network. **Green led** will solidly turn on for 5 seconds after joined in network. 240 240 237 + 241 241 [[image:1675213704414-644.png]] 242 242 243 243 ... ... @@ -257,6 +257,7 @@ 257 257 The following is the display information on the serial port and the server. 258 258 259 259 257 + 260 260 [[image:image-20230201091027-6.png]] 261 261 262 262 ... ... @@ -263,16 +263,15 @@ 263 263 [[image:image-20230201091027-7.png||height="261" width="1179"]] 264 264 265 265 264 +==== **al! ~-~- Get SDI-12 sensor Identification** ==== 266 266 267 -==== (% style="color:blue" %)**al! ~-~- Get SDI-12 sensor Identification**(%%) ==== 268 268 269 - 270 270 * AT Command: AT+ADDRI=aa 271 271 * LoRaWAN Downlink(prefix 0xAA00): AA 00 aa 272 272 273 - (% style="color:#037691" %)**Parameter: **(%%)aa: ASCII value of SDI-12 sensor address in downlink or HEX value in AT Command)270 +**Parameter: **aa: ASCII value of SDI-12 sensor address in downlink or HEX value in AT Command) 274 274 275 - (% style="color:blue" %)**Example :(%%)AT+ADDRI=0 ( Equal to downlink: 0x AA 00 30)272 +**Example : **AT+ADDRI=0 ( Equal to downlink: 0x AA 00 30) 276 276 277 277 278 278 The following is the display information on the serial port and the server. ... ... @@ -284,31 +284,30 @@ 284 284 [[image:image-20230201091257-9.png||height="225" width="1242"]] 285 285 286 286 287 -==== (% style="color:blue" %)**aM!,aMC!, aM1!- aM9!, aMC1!- aMC9!**(%%)====284 +==== **aM!,aMC!, aM1!- aM9!, aMC1!- aMC9!** ==== 288 288 289 289 290 - (% style="color:red" %)**aM! **(%%): Start Non-Concurrent Measurement287 +**aM! **: Start Non-Concurrent Measurement 291 291 292 - (% style="color:red" %)**aMC! **(%%): Start Non-Concurrent Measurement – Request CRC289 +**aMC! **: Start Non-Concurrent Measurement – Request CRC 293 293 294 - (% style="color:red" %)**aM1!- aM9! **(%%): Additional Measurements291 +**aM1!- aM9! **: Additional Measurements 295 295 296 - (% style="color:red" %)**aMC1!- aMC9!**(%%): Additional Measurements – Request CRC293 +**aMC1!- aMC9!** : Additional Measurements – Request CRC 297 297 298 298 299 299 * AT Command : AT+ADDRM=0,1,0,1 300 - 301 301 * LoRaWAN Downlink(prefix 0xAA01): 0xAA 01 30 01 00 01 302 302 303 303 Downlink:AA 01 aa bb cc dd 304 304 305 - (% style="color:#037691" %)**aa**(%%): SDI-12 sensor address.301 +**aa**: SDI-12 sensor address. 306 306 307 - (% style="color:#037691" %)**bb**(%%): 0: no CRC, 1: request CRC303 +**bb**: 0: no CRC, 1: request CRC 308 308 309 - (% style="color:#037691" %)**cc**(%%): 1-9: Additional Measurement, 0: no additional measurement305 +**cc**: 1-9: Additional Measurement, 0: no additional measurement 310 310 311 - (% style="color:#037691" %)**dd**(%%): delay (in second) to send(% style="color:#037691" %)__**aD0!**__(%%)to get return.307 +**dd**: delay (in second) to send **aD0!** to get return. 312 312 313 313 314 314 The following is the display information on the serial port and the server. ... ... @@ -321,16 +321,16 @@ 321 321 322 322 323 323 324 -==== (% style="color:blue" %)**aC!, aCC!, aC1!- aC9!, aCC1!- aCC9! **(%%)====320 +==== **aC!, aCC!, aC1!- aC9!, aCC1!- aCC9! ** ==== 325 325 326 326 327 - (% style="color:red" %)**aC!**(%%): Start Concurrent Measurement323 +**aC!** : Start Concurrent Measurement 328 328 329 - (% style="color:red" %)**aCC!**(%%): Start Concurrent Measurement – Request CRC325 +**aCC!** : Start Concurrent Measurement – Request CRC 330 330 331 - (% style="color:red" %)**aC1!- aC9!**(%%): Start Additional Concurrent Measurements327 +**aC1!- aC9!** : Start Additional Concurrent Measurements 332 332 333 - (% style="color:red" %)**aCC1!- aCC9!**(%%): Start Additional Concurrent Measurements – Request CRC329 +**aCC1!- aCC9!** : Start Additional Concurrent Measurements – Request CRC 334 334 335 335 336 336 * AT Command : AT+ADDRC=0,1,0,1 ... ... @@ -339,13 +339,13 @@ 339 339 340 340 Downlink: AA 02 aa bb cc dd 341 341 342 - (% style="color:#037691" %)**aa**(%%): SDI-12 sensor address.338 +**aa**: SDI-12 sensor address. 343 343 344 - (% style="color:#037691" %)**bb**(%%): 0: no CRC, 1: request CRC340 +**bb**: 0: no CRC, 1: request CRC 345 345 346 - (% style="color:#037691" %)**cc**(%%): 1-9: Additional Measurement, 0: no additional measurement342 +**cc**: 1-9: Additional Measurement, 0: no additional measurement 347 347 348 - (% style="color:#037691" %)**dd**(%%): delay (in second) to send(% style="color:#037691" %)__**aD0!**__(%%)____to get return.344 +**dd**: delay (in second) to send **aD0!** to get return. 349 349 350 350 351 351 The following is the display information on the serial port and the server. ... ... @@ -357,11 +357,11 @@ 357 357 [[image:image-20230201091954-13.png||height="203" width="1117"]] 358 358 359 359 356 +(% style="display:none" %) (%%) 360 360 358 +==== **aR0!- aR9!, aRC0!- aRC9!** ==== 361 361 362 -==== (% style="color:blue" %)**aR0!- aR9!, aRC0!- aRC9!**(%%) ==== 363 363 364 - 365 365 Start Continuous Measurement 366 366 367 367 Start Continuous Measurement – Request CRC ... ... @@ -372,18 +372,19 @@ 372 372 373 373 Downlink: AA 03 aa bb cc dd 374 374 375 - (% style="color:#037691" %)**aa**(%%): SDI-12 sensor address.371 +**aa**: SDI-12 sensor address. 376 376 377 - (% style="color:#037691" %)**bb**(%%): 0: no CRC, 1: request CRC373 +**bb**: 0: no CRC, 1: request CRC 378 378 379 - (% style="color:#037691" %)**cc**(%%): 1-9: Additional Measurement, 0: no additional measurement375 +**cc**: 1-9: Additional Measurement, 0: no additional measurement 380 380 381 - (% style="color:#037691" %)**dd**(%%): delay (in second) to send(% style="color:#037691" %)__**aD0!**__(%%)to get return.377 +**dd**: delay (in second) to send **aD0!** to get return. 382 382 383 383 384 384 The following is the display information on the serial port and the server. 385 385 386 386 383 + 387 387 [[image:image-20230201092208-14.png]] 388 388 389 389 ... ... @@ -390,7 +390,7 @@ 390 390 [[image:image-20230201092208-15.png||height="214" width="1140"]] 391 391 392 392 393 -=== 2.3.2 Advance SDI-12 Debug command === 390 +=== 2.3.2 Advance SDI-12 Debug command === 394 394 395 395 396 396 This command can be used to debug all SDI-12 command. ... ... @@ -398,20 +398,20 @@ 398 398 399 399 LoRaWAN Downlink: A8 aa xx xx xx xx bb cc 400 400 401 - (% style="color:#037691" %)**aa **(%%): total SDI-12 command length398 +**aa **: total SDI-12 command length 402 402 403 - (% style="color:#037691" %)**xx **(%%): SDI-12 command400 +**xx **: SDI-12 command 404 404 405 - (% style="color:#037691" %)**bb **(%%): Delay to wait for return402 +**bb **: Delay to wait for return 406 406 407 - (% style="color:#037691" %)**cc **(%%): 0: don't uplink return to LoRaWAN, 1: Uplink return to LoRaWAN on FPORT=100404 +**cc **: 0: don't uplink return to LoRaWAN, 1: Uplink return to LoRaWAN on FPORT=100 408 408 409 409 410 - (% style="color:blue" %)**Example: **(%%)AT+CFGDEV =0RC0!,1407 +**Example: **AT+CFGDEV =0RC0!,1 411 411 412 - (% style="color:#037691" %)**0RC0! **(%%): SDI-12 Command,409 +**0RC0! **: SDI-12 Command, 413 413 414 - (% style="color:#037691" %)**1 **(%%): Delay 1 second. ( 0: 810 mini-second)411 +**1 **: Delay 1 second. ( 0: 810 mini-second) 415 415 416 416 Equal Downlink: 0xA8 05 30 52 43 30 21 01 01 417 417 ... ... @@ -422,9 +422,11 @@ 422 422 [[image:image-20230201092355-16.png]] 423 423 424 424 425 -[[image:image-20230201092355-17.png||height="426" width="1135"]] 422 +[[image:image-20230201092355-17.png||height="426" width="1135"]] 426 426 427 427 425 + 426 + 428 428 === 2.3.3 Convert ASCII to String === 429 429 430 430 ... ... @@ -433,7 +433,7 @@ 433 433 AT+CONVFORM ( Max length: 80 bytes) 434 434 435 435 436 - (% style="color:blue" %)**Example:**435 +**Example:** 437 437 438 438 1) AT+CONVFORM=0, string Convert String from String to ASCII 439 439 ... ... @@ -445,6 +445,10 @@ 445 445 [[image:1675214856590-846.png]] 446 446 447 447 447 + 448 + 449 + 450 + 448 448 === 2.3.4 Define periodically SDI-12 commands and uplink. === 449 449 450 450 ... ... @@ -453,31 +453,31 @@ 453 453 User can define max 15 SDI-12 Commands (AT+COMMAND1 ~~ AT+COMMANDF). On each uplink period (TDC time, default 20 minutes), SDI-12-LB will send these SDI-12 commands and wait for return from SDI-12 sensors. SDI-12-LB will then combine these returns and uplink via LoRaWAN. 454 454 455 455 456 -* (% style="color:blue" %)**AT Command:**459 +* ** AT Command:** 457 457 458 - (% style="color:#037691" %)**AT+COMMANDx=var1,var2,var3,var4.**461 +**AT+COMMANDx=var1,var2,var3,var4.** 459 459 460 - (% style="color:red" %)**var1**(%%): SDI-12 command , for example: 0RC0!463 +**var1**: SDI-12 command , for example: 0RC0! 461 461 462 - (% style="color:red" %)**var2**(%%): Wait timeout for return. (unit: second)465 +**var2**: Wait timeout for return. (unit: second) 463 463 464 - (% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//.467 +**var3**: Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. 465 465 466 - (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB will resend this command. Max3retries.469 +**var4**: validation check for return. If return invalid, SDI-12-LB will resend this command. Max 2 retries. 467 467 468 - (% style="color:red" %)**0 **(%%)No validation check;471 +**0 ** No validation check; 469 469 470 - (% style="color:red" %)**1**(%%)Check if return chars are printable char(0x20 ~~ 0x7E);473 +**1** Check if return chars are printable char(0x20 ~~ 0x7E); 471 471 472 - (% style="color:red" %)**2**(%%)Check if there is return from SDI-12 sensor475 +**2** Check if there is return from SDI-12 sensor 473 473 474 - (% style="color:red" %)**3**(%%)Check if return pass CRC check ( SDI-12 command var1 must include CRC request);477 +**3** Check if return pass CRC check ( SDI-12 command var1 must include CRC request); 475 475 476 476 477 -Each AT+COMMANDx is followed by a (% style="color:blue" %)**AT+DATACUT**(%%)command. AT+DATACUT command is used to take the useful string from the SDI-12 sensor so the final payload will have the minimum length to uplink.480 +Each AT+COMMANDx is followed by a **AT+DATACUT** command. AT+DATACUT command is used to take the useful string from the SDI-12 sensor so the final payload will have the minimum length to uplink. 478 478 479 479 480 - (% style="color:blue" %)**AT+DATACUTx**(%%): This command defines how to handle the return from AT+COMMANDx, max return length is 100 bytes.483 +**AT+DATACUTx** : This command defines how to handle the return from AT+COMMANDx, max return length is 100 bytes. 481 481 482 482 (% border="1" style="background-color:#f7faff; width:436px" %) 483 483 |(% style="width:433px" %)((( ... ... @@ -485,64 +485,64 @@ 485 485 486 486 **a**: length for the return of AT+COMMAND 487 487 488 -**b**: 491 +**b**: 1: grab valid value by byte, max 6 bytes. 2: grab valid value by bytes section, max 3 sections. 489 489 490 490 **c**: define the position for valid value. 491 491 ))) 492 492 493 -For example, if return from AT+COMMAND1 is “013METER TER12 112T12-00024895 <CR><LF>” , Below AT+DATACUT1 will get different result to combine payload:496 +For example, if return from AT+COMMAND1 is “013METER TER12 112T12-00024895” , Below AT+DATACUT1 will get different result to combine payload: 494 494 495 495 496 496 (% border="1" cellspacing="4" style="background-color:#f7faff; width:510px" %) 497 -| =(% style="width:64px;" %)**AT+DATACUT1 value**|=(% style="width:44px;" %)**Final Result to combine Payload**498 -|(% style="width:1 64px" %)34,1,1+2+3|(% style="width:344px" %)0D 00 01 30 31 33499 -|(% style="width:1 64px" %)34,2,1~~8+12~~16|(% style="width:344px" %)0D 00 01 30 31 33 4D 45 54 45 52 54 45 52 31 32500 -|(% style="width:1 64px" %)34,2,1~~34|(% style="width:344px" %)0D 00 01 30 31 33 4D 45 54 45 52 20 20 20 54 45 52 31 32 20 31 31 32 54 31 32 2D 30 30 30 32 34 38 39 35 0D 0A500 +|(% style="width:170px" %)**AT+DATACUT1 value**|(% style="width:338px" %)**Final Result to combine Payload** 501 +|(% style="width:170px" %)34,1,1+2+3|(% style="width:338px" %)0D 00 01 30 31 33 502 +|(% style="width:170px" %)34,2,1~~8+12~~16|(% style="width:338px" %)0D 00 01 30 31 33 4D 45 54 45 52 54 45 52 31 32 503 +|(% style="width:170px" %)34,2,1~~34|(% style="width:338px" %)0D 00 01 30 31 33 4D 45 54 45 52 20 20 20 54 45 52 31 32 20 31 31 32 54 31 32 2D 30 30 30 32 34 38 39 35 0D 0A 501 501 502 -* (% style="color:blue" %)** Downlink Payload:**505 +* ** Downlink Payload:** 503 503 504 - (% style="color:blue" %)**0xAF**(%%)downlink command can be used to set AT+COMMANDx or AT+DATACUTx.507 +**0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 505 505 506 506 507 - (% style="color:red" %)**Note : if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.**510 +**Note : if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.** 508 508 509 509 510 -Format: ** (% style="color:#037691" %)AF MM NN LL XX XX XX XX YY(%%)**513 +Format: ** AF MM NN LL XX XX XX XX YY** 511 511 512 512 Where: 513 513 514 -* (% style="color:#037691" %)**MM **(%%): the AT+COMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,515 -* (% style="color:#037691" %)**NN **(%%): 1: set the AT+COMMAND value ; 2: set the AT+DATACUT value.516 -* (% style="color:#037691" %)**LL **(%%): The length of AT+COMMAND or AT+DATACUT command517 -* (% style="color:#037691" %)**XX XX XX XX **(%%): AT+COMMAND or AT+DATACUT command518 -* (% style="color:#037691" %)**YY **(%%): If YY=0, SDI-12-LBwill execute the downlink command without uplink; if YY=1, SDI-12-LBwill execute an uplink after got this command.517 +* **MM **: the AT+COMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 518 +* **NN **: 1: set the AT+DATACUT value ; 2: set the AT+DATACUT value. 519 +* **LL **: The length of AT+COMMAND or AT+DATACUT command 520 +* **XX XX XX XX **: AT+COMMAND or AT+DATACUT command 521 +* **YY **: If YY=0, RS485-LN will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command. 519 519 520 -(% style="color:blue" %)**Example:** 521 521 524 +**Example:** 525 + 522 522 [[image:image-20230201094129-18.png]] 523 523 524 524 529 +**Clear SDI12 Command** 525 525 526 -(% style="color:blue" %)**Clear SDI12 Command** 527 - 528 528 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 529 529 530 530 531 -* (% style="color:#037691" %)**AT Command:**534 +* ** AT Command:** 532 532 533 - (% style="color:#4f81bd" %)**AT+CMDEAR=mm,nn**(%%)mm: start position of erase ,nn: stop position of erase536 +**~ AT+CMDEAR=mm,nn** mm: start position of erase ,nn: stop position of erase 534 534 535 535 536 536 Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 537 537 538 538 539 -* (% style="color:#037691" %)** Downlink Payload:**542 +* ** Downlink Payload:** 540 540 541 - (% style="color:#4f81bd" %)**0x09 aa bb**(%%)same as AT+CMDEAR=aa,bb544 +**~ 0x09 aa bb** same as AT+CMDEAR=aa,bb 542 542 543 543 544 544 545 - (% style="color:blue" %)**command combination**548 +**command combination** 546 546 547 547 Below shows a screen shot how the results combines together to a uplink payload. 548 548 ... ... @@ -551,26 +551,26 @@ 551 551 552 552 If user don't want to use DATACUT for some command, he simply want to uplink all returns. AT+ALLDATAMOD can be set to 1. 553 553 554 - (% style="color:blue" %)**AT+ALLDATAMOD**(%%)will simply get all return and don't do CRC check as result for SDI-12 command. AT+DATACUTx command has higher priority, if AT+DATACUTx has been set, AT+ALLDATAMOD will be ignore for this SDI-12 command.557 +**AT+ALLDATAMOD** will simply get all return and don’t do CRC check as result for SDI-12 command. AT+DATACUTx command has higher priority, if AT+DATACUTx has been set, AT+ALLDATAMOD will be ignore for this SDI-12 command. 555 555 556 556 557 - (% style="color:#4f81bd" %)**For example: **(%%)as below photo, AT+ALLDATAMOD=1, but AT+DATACUT1 has been set, AT+DATACUT1 will be still effect the result.560 +**For example: ** as below photo, AT+ALLDATAMOD=1, but AT+DATACUT1 has been set, AT+DATACUT1 will be still effect the result. 558 558 559 559 560 560 [[image:1675215782925-448.png]] 561 561 562 562 563 -If AT+ALLDATAMOD=1, (% style="color:#4f81bd" %)**FX,X**(%%)will be added in the payload, FX specify which command is used and X specify the length of return. for example in above screen, F1 05 means the return is from AT+COMMAND1 and the return is 5 bytes.566 +If AT+ALLDATAMOD=1, **FX,X** will be added in the payload, FX specify which command is used and X specify the length of return. for example in above screen, F1 05 means the return is from AT+COMMAND1 and the return is 5 bytes. 564 564 565 565 566 566 567 - (% style="color:blue" %)**Compose Uplink**570 +**Compose Uplink** 568 568 569 - (% style="color:#4f81bd" %)**AT+DATAUP=0**572 +**AT+DATAUP=0** 570 570 571 -Compose the uplink payload with value returns in sequence and send with **__A SIGNLE UPLINK__**.574 +Compose the uplink payload with value returns in sequence and send with A SIGNLE UPLINK. 572 572 573 -Final Payload is **__Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx__**576 +Final Payload is Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx 574 574 575 575 Where PAYVER is defined by AT+PAYVER, below is an example screen shot. 576 576 ... ... @@ -578,12 +578,14 @@ 578 578 [[image:1675215828102-844.png]] 579 579 580 580 581 - (% style="color:#4f81bd" %)**AT+DATAUP=1**584 +**AT+DATAUP=1** 582 582 583 -Compose the uplink payload with value returns in sequence and send with **__Multiply UPLINKs__**.586 +Compose the uplink payload with value returns in sequence and send with Multiply UPLINKs. 584 584 585 -Final Payload is __**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**__588 +Final Payload is 586 586 590 +__**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**__ 591 + 587 587 1. Battery Info (2 bytes): Battery voltage 588 588 1. PAYVER (1 byte): Defined by AT+PAYVER 589 589 1. PAYLOAD COUNT (1 byte): Total how many uplinks of this sampling. ... ... @@ -593,7 +593,7 @@ 593 593 [[image:1675215848113-696.png]] 594 594 595 595 596 - (% style="color:red" %)**Notice: the Max bytes is according to the max support bytes in different Frequency Bands for lowest SF. As below:**601 +**Notice: the Max bytes is according to the max support bytes in different Frequency Bands for lowest SF. As below:** 597 597 598 598 * For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink ( so 51 -5 = 46 max valid date) 599 599 * For AU915/AS923 bands, if UplinkDwell time=1, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date). ... ... @@ -600,36 +600,45 @@ 600 600 * For US915 band, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date). 601 601 * For all other bands: max 51 bytes for each uplink ( so 51 -5 = 46 max valid date). 602 602 603 - (% style="color:red" %)**When AT+DATAUP=1, the maximum number of segments is 15, and the maximum total number of bytes is 1500;**608 +**~ When AT+DATAUP=1, the maximum number of segments is 15, and the maximum total number of bytes is 1500;** 604 604 605 - (% style="color:red" %)**When AT+DATAUP=1 and AT+ADR=0, the maximum number of bytes of each payload is determined by the DR value.**610 +**~ When AT+DATAUP=1 and AT+ADR=0, the maximum number of bytes of each payload is determined by the DR value.** 606 606 607 607 608 -== 2.4 Uplink Payload == 613 +== 2.4 Uplink Payload == 609 609 610 -=== 2.4.1 Device Payload, FPORT~=5 === 611 611 616 +Uplink payloads have two types: 612 612 618 +* Distance Value: Use FPORT=2 619 +* Other control commands: Use other FPORT fields. 620 + 621 +The application server should parse the correct value based on FPORT settings. 622 + 623 + 624 +2.4.1 Device Payload, FPORT=5 625 + 613 613 Include device configure status. Once SDI-12-LB Joined the network, it will uplink this message to the server. 614 614 628 + 615 615 Users can also use the downlink command(0x26 01) to ask SDI-12-LB to resend this uplink. 616 616 617 -(% border="1" cellspacing="4" style="background-color:#f7faff; width:420px" %) 631 + 632 +(% border="1" cellspacing="4" style="background-color:#f7faff; width:437px" %) 618 618 |(% colspan="6" style="width:434px" %)**Device Status (FPORT=5)** 619 -|(% style="width:1 14px" %)**Size(bytes)**|(% style="width:39px" %)**1**|(% style="width:80px" %)**2**|(% style="width:89px" %)**1**|(% style="width:59px" %)**1**|(% style="width:37px" %)**2**620 -|(% style="width:1 14px" %)**Value**|(% style="width:39px" %)Sensor Model|(% style="width:80px" %)Firmware Version|(% style="width:89px" %)Frequency Band|(% style="width:59px" %)Sub-band|(% style="width:37px" %)BAT634 +|(% style="width:102px" %)**Size (bytes)**|(% style="width:67px" %)**1**|(% style="width:80px" %)**2**|(% style="width:89px" %)**1**|(% style="width:52px" %)**1**|(% style="width:44px" %)**2** 635 +|(% style="width:102px" %)**Value**|(% style="width:67px" %)Sensor Model|(% style="width:80px" %)Firmware Version|(% style="width:89px" %)Frequency Band|(% style="width:52px" %)Sub-band|(% style="width:44px" %)BAT 621 621 622 622 Example parse in TTNv3 623 623 624 624 [[image:1675215946738-635.png]] 625 625 641 +**Sensor Model**: For SDI-12-LB, this value is 0x17 626 626 627 - (% style="color:#037691" %)**SensorModel**(%%):For SDI-12-LB,this valueis0x17643 +**Firmware Version**: 0x0100, Means: v1.0.0 version 628 628 629 - (% style="color:#037691" %)**FirmwareVersion**(%%):0x0100, Means:v1.0.0 version645 +**Frequency Band**: 630 630 631 -(% style="color:#037691" %)**Frequency Band**: 632 - 633 633 *0x01: EU868 634 634 635 635 *0x02: US915 ... ... @@ -659,7 +659,7 @@ 659 659 *0x0e: MA869 660 660 661 661 662 - (% style="color:#037691" %)**Sub-Band**:676 +**Sub-Band**: 663 663 664 664 AU915 and US915:value 0x00 ~~ 0x08 665 665 ... ... @@ -668,7 +668,7 @@ 668 668 Other Bands: Always 0x00 669 669 670 670 671 - (% style="color:#037691" %)**Battery Info**:685 +**Battery Info**: 672 672 673 673 Check the battery voltage. 674 674 ... ... @@ -677,9 +677,10 @@ 677 677 Ex2: 0x0B49 = 2889mV 678 678 679 679 680 -=== 2.4.2 Uplink Payload, FPORT~=2 === 694 +1. 695 +11. 696 +111. Uplink Payload, FPORT=2 681 681 682 - 683 683 There are different cases for uplink. See below 684 684 685 685 * SDI-12 Debug Command return: FPORT=100 ... ... @@ -686,24 +686,30 @@ 686 686 687 687 * Periodically Uplink: FPORT=2 688 688 689 -(% border="1" cellspacing="4" style="background-color:#f7faff; width:500px" %) 690 -|=(% style="width: 90px;" %)((( 691 -**Size(bytes)** 692 -)))|=(% style="width: 80px;" %)**2**|=(% style="width: 90px;" %)**1**|=(% style="width: 240px;" %)**Length depends on the return from the commands** 693 -|(% style="width:93px" %)**Value**|(% style="width:83px" %)((( 704 +|((( 705 +**Size** 706 + 707 +**(bytes)** 708 +)))|**2**|**1**|**Length depends on the return from the commands** 709 +|**Value**|((( 694 694 Battery(mV) 711 + 695 695 & 713 + 696 696 Interrupt_Flag 697 -)))|(% style="width:91px" %)[[PAYLOAD_VER>>||anchor="H3.6Setthepayloadversion"]]|(% style="width:212px" %)((( 698 -If the valid payload is too long and exceed the maximum support. 715 +)))|[[PAYLOAD_VER>>path:#Probe_Model]]|((( 716 +If the valid payload is too long and exceed the maximum support 717 + 699 699 Payload length in server,server will show payload not provided in the LoRaWAN server. 700 700 ))) 701 701 702 -[[image: 1675216282284-923.png]]721 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image034.png]] 703 703 704 704 705 -=== 2.4.3 Battery Info === 706 706 725 +1. 726 +11. 727 +111. Battery Info 707 707 708 708 Check the battery voltage for SDI-12-LB. 709 709 ... ... @@ -712,12 +712,14 @@ 712 712 Ex2: 0x0B49 = 2889mV 713 713 714 714 715 -=== 2.4.4 Interrupt Pin === 736 +1. 737 +11. 738 +111. Interrupt Pin 716 716 740 +This data field shows if this packet is generated by **Interrupt Pin** or not. [[Click here>>path:#Int_mod]] for the hardware and software set up. Note: The Internet Pin is a separate pin in the screw terminal. See [[pin mapping>>path:#pins]]. 717 717 718 -This data field shows if this packet is generated by (% style="color:#037691" %)**Interrupt Pin**(%%) or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up. Note: The Internet Pin is a separate pin in the screw terminal. See [[pin mapping>>||anchor="H1.7PinMapping"]]. 719 719 720 - **Example:**743 +Example: 721 721 722 722 Ex1: 0x0B45:0x0B&0x80= 0x00 Normal uplink packet. 723 723 ... ... @@ -724,127 +724,242 @@ 724 724 Ex2: 0x8B49:0x8B&0x80= 0x80 Interrupt Uplink Packet. 725 725 726 726 727 -=== 2.4.5 Payload version === 750 +1. 751 +11. 752 +111. Payload version 728 728 729 -The version number of the payload, mainly used for decoding. The default is 01. 730 730 731 731 732 -=== 2.4.6 Decode payload in The Things Network === 733 733 734 734 758 +1. 759 +11. 760 +111. Decode payload in The Things Network 761 + 735 735 While using TTN network, you can add the payload format to decode the payload. 736 736 737 -[[image: 1675216779406-595.png]]764 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] 738 738 739 739 740 740 There is no fix payload decoder in LoRaWAN server because the SDI-12 sensors returns are different. User need to write the decoder themselves for their case. 741 741 742 -SDI-12-LB TTN Payload Decoder: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>url:https://github.com/dragino/dragino-end-node-decoder]] 743 743 770 +下面的解码生成超链接放进去. 744 744 745 - == 2.5 UplinkInterval==772 +function Decoder(bytes, port) { 746 746 774 + if(port==5) 747 747 748 - TheSDI-12-LBby default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link:776 + { 749 749 750 - [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]778 + var freq_band; 751 751 780 + var sub_band; 752 752 753 - ==2.6ExamplesToSet SDI commands. ==782 + var sensor; 754 754 755 -=== 2.6.1 Examples 1 === 756 756 785 + if(bytes[0]==0x17) 757 757 758 - COM portandSDI-12sensorcommunication converted toSDI-12-LBand SDI-12 sensor communication.787 + sensor= "SDI12-LB"; 759 759 760 -[[image:image-20230222143809-1.png||height="564" width="729"]] 761 761 790 + var firm_ver= (bytes[1]&0x0f)+'.'+(bytes[2]>>4&0x0f)+'.'+(bytes[2]&0x0f); 762 762 763 -(% style="color:blue" %)**1) The AT+COMMANDx command is applied to the red arrow part, and sends the SDI12 command to the SDI12 sensor:** 764 764 765 - a.Sendthefirstcommand and get the firstreply:793 + if(bytes[3]==0x01) 766 766 767 - (%style="color:#037691"%)**AT+COMMANDx=1I!,0,0,1**795 + freq_band="EU868"; 768 768 769 - b.Sendthesecondcommandandgetthecondreply:797 + else if(bytes[3]==0x02) 770 770 771 - (%style="color:#037691"%)**AT+COMMANDx=2I!,0,0,1**799 + freq_band="US915"; 772 772 773 - c.Sendthethirdcommandandgetthethird reply:801 + else if(bytes[3]==0x03) 774 774 775 - (%style="color:#037691"%)**AT+COMMANDx=3I!,0,0,1**803 + freq_band="IN865"; 776 776 777 - d.Sendthefourthcommandandgetthe fourth reply:805 + else if(bytes[3]==0x04) 778 778 779 - (%style="color:#037691"%)**AT+COMMANDx=4I!,0,0,1**807 + freq_band="AU915"; 780 780 781 - e.Sendthefifthcommandplusthesixth command, get thesixth reply:809 + else if(bytes[3]==0x05) 782 782 783 - (%style="color:#037691"%)**AT+COMMANDx=1M!,2,1,1**811 + freq_band="KZ865"; 784 784 785 - f.Sendtheseventhcommandplustheeighth command, getthe eighth reply:813 + else if(bytes[3]==0x06) 786 786 787 - (%style="color:#037691"%)**AT+COMMANDx=2M!,2,1,1**815 + freq_band="RU864"; 788 788 789 - g.Sendtheninthcommandplusthetenth command, getthetenth reply:817 + else if(bytes[3]==0x07) 790 790 791 - (%style="color:#037691" %)**AT+COMMANDx=3M!,1,1,1**819 + freq_band="AS923"; 792 792 793 - h.Sendtheeleventhcommandplusthetwelfth command, getthe twelfth reply:821 + else if(bytes[3]==0x08) 794 794 795 - (%style="color:#037691"%)**AT+COMMANDx=4M!,1,1,1**823 + freq_band="AS923_1"; 796 796 825 + else if(bytes[3]==0x09) 797 797 798 - (%style="color:blue"%)**2) TheAT+DATACUTxcommandisappliedtothe greenarrow part, receiving andcut out data from theSDI12sensor:**827 + freq_band="AS923_2"; 799 799 800 - a.Thefirstreply,all34characters: ”113TRUEBNERSMT100038220303182331<CR><LF>”829 + else if(bytes[3]==0x0A) 801 801 802 - Cutoutallcharacters:(%style="color:#037691"%)**AT+ALLDATAMOD=1orAT+DATACUTx=34,2,1~~34**;831 + freq_band="AS923_3"; 803 803 804 - b. Thesixthreply,all31characters:”1+19210+1.04+0.00+22.49+11.75<CR><LF>”833 + else if(bytes[3]==0x0F) 805 805 806 - Cutoutallcharacters:(%style="color:#037691"%)**AT+ALLDATAMOD=1orAT+DATACUTx=31,2,1~~31**;835 + freq_band="AS923_4"; 807 807 808 - c. Theeighthreply,all31characters:”2+18990+1.08+0.00+22.24+11.80<CR><LF>”837 + else if(bytes[3]==0x0B) 809 809 810 - Cutoutallcharacters:(%style="color:#037691"%)**AT+ALLDATAMOD=1orAT+DATACUTx=31,2,1~~31**;839 + freq_band="CN470"; 811 811 812 - d. Thetenthreply,all15characters:”3-2919.8+24.0<CR><LF>”841 + else if(bytes[3]==0x0C) 813 813 814 - Cutoutallcharacters:(%style="color:#037691"%)**AT+ALLDATAMOD=1orAT+DATACUTx=15,2,1~~15**;843 + freq_band="EU433"; 815 815 816 - e. Thetwelfthreply,all25characters:”4+30.8+22.84+4.7+954.38<CR><LF>”845 + else if(bytes[3]==0x0D) 817 817 818 - Partialcut,thecutsensoraddressandthefirst two parameters:(% style="color:#037691" %)**AT+DATACUTx=25,2,1~~12, cut out the character field ” 4+30.8+22.84”**.847 + freq_band="KR920"; 819 819 849 + else if(bytes[3]==0x0E) 820 820 821 - ==2.7Frequency Plans==851 + freq_band="MA869"; 822 822 823 823 824 - TheSDI-12-LBusesOTAAmode and belowfrequency plansbydefault. If user want to use it with different frequency plan, please refer the AT command sets.854 + if(bytes[4]==0xff) 825 825 826 - [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]856 + sub_band="NULL"; 827 827 858 + else 828 828 829 - ==2.8FirmwareChangeLog==860 + sub_band=bytes[4]; 830 830 831 831 863 + var bat= (bytes[5]<<8 | bytes[6])/1000; 864 + 865 + 866 + return { 867 + 868 + SENSOR_MODEL:sensor, 869 + 870 + FIRMWARE_VERSION:firm_ver, 871 + 872 + FREQUENCY_BAND:freq_band, 873 + 874 + SUB_BAND:sub_band, 875 + 876 + BAT:bat, 877 + 878 + } 879 + 880 + } 881 + 882 + else if(port==100) 883 + 884 + { 885 + 886 + var datas_sum={}; 887 + 888 + for(var j=0;j<bytes.length;j++) 889 + 890 + { 891 + 892 + var datas= String.fromCharCode(bytes[j]); 893 + 894 + if(j=='0') 895 + 896 + datas_sum.datas_sum=datas; 897 + 898 + else 899 + 900 + datas_sum.datas_sum+=datas; 901 + 902 + } 903 + 904 + 905 + return datas_sum; 906 + 907 + } 908 + 909 + else 910 + 911 + { 912 + 913 + var decode={}; 914 + 915 + decode.EXTI_Trigger= (bytes[0] & 0x80)? "TRUE":"FALSE"; 916 + 917 + decode.BatV= ((bytes[0]<<8 | bytes[1])&0x7FFF)/1000; 918 + 919 + decode.Payver= bytes[2]; 920 + 921 + for(var i=3;i<bytes.length;i++) 922 + 923 + { 924 + 925 + var data= String.fromCharCode(bytes[i]); 926 + 927 + if(i=='3') 928 + 929 + decode.data_sum=data; 930 + 931 + else 932 + 933 + decode.data_sum+=data; 934 + 935 + } 936 + 937 + return decode; 938 + 939 + } 940 + 941 + 942 +} 943 + 944 + 945 +1. 946 +11. Uplink Interval 947 + 948 +The SDI-12-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: 949 + 950 +[[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval]] 951 + 952 + 953 + 954 +1. 955 +11. Frequency Plans 956 + 957 +The SDI12-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 958 + 959 + 960 +[[https:~~/~~/wiki.dragino.com/index.php?title=End_Device_Frequency_Band>>url:https://wiki.dragino.com/index.php?title=End_Device_Frequency_Band]] 961 + 962 + 963 + 964 +1. 965 +11. Firmware Change Log 966 + 832 832 **Firmware download link:** 833 833 834 -[[https:~~/~~/www.dropbox.com/sh/ qrbgbikb109lkiv/AACBR-v_ZhZAMengcY7Nsa1ja?dl=0>>https://www.dropbox.com/sh/qrbgbikb109lkiv/AACBR-v_ZhZAMengcY7Nsa1ja?dl=0]]969 +[[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]] 835 835 836 836 837 -= 3. Configure SDI-12-LB via AT Command or LoRaWAN Downlink = 838 838 973 +1. Configure SDI-12-LB via AT Command or LoRaWAN Downlink 839 839 840 840 Use can configure SDI-12-LB via AT Command or LoRaWAN Downlink. 841 841 842 -* AT Command Connection: See [[FAQ>> ||anchor="H7.FAQ"]].843 -* LoRaWAN Downlink instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.977 +* AT Command Connection: See [[FAQ>>path:#AT_COMMAND]]. 978 +* LoRaWAN Downlink instruction for different platforms: 844 844 980 +[[http:~~/~~/wiki.dragino.com/index.php?title=Main_Page#Use_Note_for_Server>>url:http://wiki.dragino.com/index.php?title=Main_Page#Use_Note_for_Server]] 981 + 982 + 845 845 There are two kinds of commands to configure SDI-12-LB, they are: 846 846 847 -* (% style="color:blue" %)**General Commands**.985 +* **General Commands**. 848 848 849 849 These commands are to configure: 850 850 ... ... @@ -853,232 +853,255 @@ 853 853 854 854 They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 855 855 856 -[[http:~~/~~/wiki.dragino.com/ xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]994 +[[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_Downlink_Command>>url:http://wiki.dragino.com/index.php?title=End_Device_Downlink_Command]] 857 857 858 858 859 -* (% style="color:blue" %)**Commands special design for SDI-12-LB**997 +* **Commands special design for SDI-12-LB** 860 860 861 861 These commands only valid for SDI-12-LB, as below: 862 862 863 863 864 -== 3.1 Set Transmit Interval Time == 865 865 1003 +1. 1004 +11. Set Transmit Interval Time 866 866 867 867 Feature: Change LoRaWAN End Node Transmit Interval. 868 868 869 - (% style="color:blue" %)**AT Command: AT+TDC**1008 +**AT Command: AT+TDC** 870 870 871 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 872 -|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 137px;" %)**Function**|=**Response** 873 -|(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|((( 1010 +|**Command Example**|**Function**|**Response** 1011 +|AT+TDC=?|Show current transmit Interval|((( 874 874 30000 1013 + 875 875 OK 1015 + 876 876 the interval is 30000ms = 30s 877 877 ))) 878 -| (% style="width:156px" %)AT+TDC=60000|(% style="width:137px" %)Set Transmit Interval|(((1018 +|AT+TDC=60000|Set Transmit Interval|((( 879 879 OK 1020 + 880 880 Set transmit interval to 60000ms = 60 seconds 881 881 ))) 882 882 883 - (% style="color:blue" %)**Downlink Command: 0x01**1024 +**Downlink Command: 0x01** 884 884 885 - 886 886 Format: Command Code (0x01) followed by 3 bytes time value. 887 887 888 -If the downlink payload=0100003C, it means set the END Node 's Transmit Interval to 0x00003C=60(S), while type code is 01.1028 +If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01. 889 889 890 -* Example 1: Downlink Payload: 0100001E 891 -* Example 2: Downlink Payload: 0100003C 1030 +* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 1031 +* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 892 892 893 -== 3.2 Set Interrupt Mode == 1033 +1. 1034 +11. Set Interrupt Mode 894 894 895 - 896 896 Feature, Set Interrupt mode for GPIO_EXIT. 897 897 898 - (% style="color:blue" %)**AT Command: AT+INTMOD**1038 +**AT Command: AT+INTMOD** 899 899 900 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 901 -|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 187px;" %)**Function**|=(% style="width: 165px;" %)**Response** 902 -|(% style="width:156px" %)AT+INTMOD=?|(% style="width:187px" %)Show current interrupt mode|(% style="width:165px" %)((( 1040 +|**Command Example**|**Function**|**Response** 1041 +|AT+INTMOD=?|Show current interrupt mode|((( 903 903 0 1043 + 904 904 OK 905 -the mode is 0 = Disable Interrupt 1045 + 1046 +the mode is 0 = No interruption 906 906 ))) 907 -| (% style="width:156px" %)AT+INTMOD=2|(% style="width:187px" %)(((1048 +|AT+INTMOD=2|((( 908 908 Set Transmit Interval 909 -0. (Disable Interrupt), 910 -~1. (Trigger by rising and falling edge) 911 -2. (Trigger by falling edge) 912 -3. (Trigger by rising edge) 913 -)))|(% style="width:165px" %)OK 914 914 915 -(% style="color:blue" %)**Downlink Command: 0x06** 1051 +1. (Disable Interrupt), 1052 +1. (Trigger by rising and falling edge), 1053 +1. (Trigger by falling edge) 1054 +1. (Trigger by rising edge) 1055 +)))|OK 916 916 1057 +**Downlink Command: 0x06** 1058 + 917 917 Format: Command Code (0x06) followed by 3 bytes. 918 918 919 919 This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 920 920 921 -* Example 1: Downlink Payload: 06000000 922 -* Example 2: Downlink Payload: 06000003 1063 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 1064 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 923 923 924 -== 3.3 Set the output time == 1066 +1. 1067 +11. Set the output time 925 925 926 - 927 927 Feature, Control the output 3V3 , 5V or 12V. 928 928 929 - (% style="color:blue" %)**AT Command: AT+3V3T**1071 +**AT Command: AT+3V3T** 930 930 931 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:474px" %) 932 -|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 201px;" %)**Function**|=(% style="width: 116px;" %)**Response** 933 -|(% style="width:154px" %)AT+3V3T=?|(% style="width:201px" %)Show 3V3 open time.|(% style="width:116px" %)((( 1073 +|**Command Example**|**Function**|**Response** 1074 +|AT+3V3T=?|Show 3V3 open time.|((( 934 934 0 1076 + 935 935 OK 936 936 ))) 937 -| (% style="width:154px" %)AT+3V3T=0|(% style="width:201px" %)Normally open 3V3 power supply.|(% style="width:116px" %)(((1079 +|AT+3V3T=0|Normally open 3V3 power supply.|((( 938 938 OK 1081 + 939 939 default setting 940 940 ))) 941 -| (% style="width:154px" %)AT+3V3T=1000|(% style="width:201px" %)Close after a delay of 1000 milliseconds.|(% style="width:116px" %)(((1084 +|AT+3V3T=1000|Close after a delay of 1000 milliseconds.|((( 942 942 OK 1086 + 1087 + 943 943 ))) 944 -| (% style="width:154px" %)AT+3V3T=65535|(% style="width:201px" %)Normally closed 3V3 power supply.|(% style="width:116px" %)(((1089 +|AT+3V3T=65535|Normally closed 3V3 power supply.|((( 945 945 OK 1091 + 1092 + 946 946 ))) 947 947 948 - (% style="color:blue" %)**AT Command: AT+5VT**1095 +**AT Command: AT+5VT** 949 949 950 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:470px" %) 951 -|=(% style="width: 155px;" %)**Command Example**|=(% style="width: 196px;" %)**Function**|=(% style="width: 114px;" %)**Response** 952 -|(% style="width:155px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:114px" %)((( 1097 +|**Command Example**|**Function**|**Response** 1098 +|AT+5VT=?|Show 5V open time.|((( 953 953 0 1100 + 954 954 OK 955 955 ))) 956 -| (% style="width:155px" %)AT+5VT=0|(% style="width:196px" %)Normally closed 5V power supply.|(% style="width:114px" %)(((1103 +|AT+5VT=0|Normally closed 5V power supply.|((( 957 957 OK 1105 + 958 958 default setting 959 959 ))) 960 -| (% style="width:155px" %)AT+5VT=1000|(% style="width:196px" %)Close after a delay of 1000 milliseconds.|(% style="width:114px" %)(((1108 +|AT+5VT=1000|Close after a delay of 1000 milliseconds.|((( 961 961 OK 1110 + 1111 + 962 962 ))) 963 -| (% style="width:155px" %)AT+5VT=65535|(% style="width:196px" %)Normally open 5V power supply.|(% style="width:114px" %)(((1113 +|AT+5VT=65535|Normally open 5V power supply.|((( 964 964 OK 1115 + 1116 + 965 965 ))) 966 966 967 - (% style="color:blue" %)**AT Command: AT+12VT**1119 +**AT Command: AT+12VT** 968 968 969 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:443px" %) 970 -|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 199px;" %)**Function**|=(% style="width: 83px;" %)**Response** 971 -|(% style="width:156px" %)AT+12VT=?|(% style="width:199px" %)Show 12V open time.|(% style="width:83px" %)((( 1121 +|**Command Example**|**Function**|**Response** 1122 +|AT+12VT=?|Show 12V open time.|((( 972 972 0 1124 + 973 973 OK 974 974 ))) 975 -| (% style="width:156px" %)AT+12VT=0|(% style="width:199px" %)Normally closed 12V power supply.|(% style="width:83px" %)OK976 -| (% style="width:156px" %)AT+12VT=500|(% style="width:199px" %)Close after a delay of 500 milliseconds.|(% style="width:83px" %)(((1127 +|AT+12VT=0|Normally closed 12V power supply.|OK 1128 +|AT+12VT=500|Close after a delay of 500 milliseconds.|((( 977 977 OK 1130 + 1131 + 978 978 ))) 979 979 980 - (% style="color:blue" %)**Downlink Command: 0x07**1134 +**Downlink Command: 0x07** 981 981 982 982 Format: Command Code (0x07) followed by 3 bytes. 983 983 984 984 The first byte is which power, the second and third bytes are the time to turn on. 985 985 986 -* Example 1: Downlink Payload: 070101F4 **~-~-->**987 -* Example 2: Downlink Payload: 0701FFFF **~-~-->**AT+3V3T=65535988 -* Example 3: Downlink Payload: 070203E8 **~-~-->**AT+5VT=1000989 -* Example 4: Downlink Payload: 07020000 **~-~-->**AT+5VT=0990 -* Example 5: Downlink Payload: 070301F4 **~-~-->**AT+12VT=500991 -* Example 6: Downlink Payload: 07030000 **~-~-->**AT+12VT=01140 +* Example 1: Downlink Payload: 070101F4 -> AT+3V3T=500 1141 +* Example 2: Downlink Payload: 0701FFFF -> AT+3V3T=65535 1142 +* Example 3: Downlink Payload: 070203E8 -> AT+5VT=1000 1143 +* Example 4: Downlink Payload: 07020000 -> AT+5VT=0 1144 +* Example 5: Downlink Payload: 070301F4 -> AT+12VT=500 1145 +* Example 6: Downlink Payload: 07030000 -> AT+12VT=0 992 992 993 -== 3.4 Set the all data mode == 1147 +1. 1148 +11. Set the all data mode 994 994 995 - 996 996 Feature, Set the all data mode. 997 997 998 - (% style="color:blue" %)**AT Command: AT+ALLDATAMOD**1152 +**AT Command: AT+ALLDATAMOD** 999 999 1000 -(% border="1" cellspacing="4" style="background-color:#f7faff; width:437px" %) 1001 -|=**Command Example**|=**Function**|=**Response** 1154 +|**Command Example**|**Function**|**Response** 1002 1002 |AT+ALLDATAMOD=?|Show current all data mode|((( 1003 1003 0 1157 + 1158 + 1004 1004 OK 1005 1005 ))) 1006 1006 |AT+ALLDATAMOD=1|Set all data mode is 1.|OK 1007 1007 1008 - (% style="color:blue" %)**Downlink Command: 0xAB**1163 +**Downlink Command: 0xAB** 1009 1009 1010 1010 Format: Command Code (0xAB) followed by 1 bytes. 1011 1011 1012 -* Example 1: Downlink Payload: AB 00 1013 -* Example 2: Downlink Payload: AB 01 1167 +* Example 1: Downlink Payload: AB 00 ~/~/ AT+ALLDATAMOD=0 1168 +* Example 2: Downlink Payload: AB 01 ~/~/ AT+ALLDATAMOD=1 1014 1014 1015 -== 3.5 Set the splicing payload for uplink == 1170 +1. 1171 +11. Set the splicing payload for uplink 1016 1016 1017 - 1018 1018 Feature, splicing payload for uplink. 1019 1019 1020 - (% style="color:blue" %)**AT Command: AT+DATAUP**1175 +**AT Command: AT+DATAUP** 1021 1021 1022 -(% border="1" cellspacing="4" style="background-color:#f7faff; width:510px" %) 1023 -|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 266px;" %)**Function**|=**Response** 1024 -|(% style="width:154px" %)AT+DATAUP =?|(% style="width:266px" %)Show current splicing payload for uplink mode|((( 1177 +|**Command Example**|**Function**|**Response** 1178 +|AT+DATAUP =?|Show current splicing payload for uplink mode|((( 1025 1025 0 1180 + 1181 + 1026 1026 OK 1027 1027 ))) 1028 -| (% style="width:154px" %)AT+DATAUP =0|(% style="width:266px" %)(((1184 +|AT+DATAUP =0|((( 1029 1029 Set splicing payload for uplink mode is 0. 1186 + 1187 + 1030 1030 )))|((( 1031 1031 OK 1190 + 1191 + 1032 1032 ))) 1033 -|(% style="width:154px" %)AT+DATAUP =1|(% style="width:266px" %)Set splicing payload for uplink mode is 1 , and the each splice uplink is sent sequentially.|OK 1034 -|(% style="width:154px" %)AT+DATAUP =1,20000|(% style="width:266px" %)((( 1035 -Set splicing payload for uplink mode is 1, and the uplink interval of each splice to 20000 milliseconds. 1193 +|AT+DATAUP =1|Set splicing payload for uplink mode is 1 , and the each splice uplink is sent sequentially.|OK 1194 +|AT+DATAUP =1,20000|((( 1195 +Set splicing payload for uplink mode is 1, and the uplink interval of each splice to 20000 milliseconds. 1196 + 1197 + 1036 1036 )))|OK 1037 1037 1038 - (% style="color:blue" %)**Downlink Command: 0xAD**1200 +**Downlink Command: 0xAD** 1039 1039 1040 1040 Format: Command Code (0xAD) followed by 1 bytes or 5 bytes. 1041 1041 1042 -* Example 1: Downlink Payload: AD 00 1043 -* Example 2: Downlink Payload: AD 01 1044 -* Example 3: Downlink Payload: AD 01 00 00 14 1204 +* Example 1: Downlink Payload: AD 00 ~/~/ AT+DATAUP=0 1205 +* Example 2: Downlink Payload: AD 01 ~/~/ AT+DATAUP =1 1206 +* Example 3: Downlink Payload: AD 01 00 00 14~/~/ AT+DATAUP =1,20000 1045 1045 1046 1046 This means that the interval is set to 0x000014=20S 1047 1047 1048 1048 1049 -== 3.6 Set the payload version == 1211 +1. 1212 +11. Set the payload version 1050 1050 1051 - 1052 1052 Feature, Set the payload version. 1053 1053 1054 - (% style="color:blue" %)**AT Command: AT+PAYVER**1216 +**AT Command: AT+PAYVER** 1055 1055 1056 -(% border="1" cellspacing="4" style="background-color:#f7faff; width:437px" %) 1057 -|=(% style="width: 158px;" %)**Command Example**|=(% style="width: 192px;" %)**Function**|=**Response** 1058 -|(% style="width:158px" %)AT+PAYVER=?|(% style="width:192px" %)Show current payload version|((( 1218 +|**Command Example**|**Function**|**Response** 1219 +|AT+PAYVER=?|Show current payload version|((( 1059 1059 1 1221 + 1222 + 1060 1060 OK 1061 1061 ))) 1062 -| (% style="width:158px" %)AT+PAYVER=5|(% style="width:192px" %)Set payload version is 5.|OK1225 +|AT+PAYVER=5|Set payload version is 5.|OK 1063 1063 1064 - (% style="color:blue" %)**Downlink Command: 0xAE**1227 +**Downlink Command: 0xAE** 1065 1065 1066 1066 Format: Command Code (0xAE) followed by 1 bytes. 1067 1067 1068 -* Example 1: Downlink Payload: AE 01 1069 -* Example 2: Downlink Payload: AE 05 1231 +* Example 1: Downlink Payload: AE 01 ~/~/ AT+PAYVER=1 1232 +* Example 2: Downlink Payload: AE 05 ~/~/ AT+PAYVER=5 1070 1070 1071 -= 4. Battery & how to replace = 1234 +1. Battery & how to replace 1235 +11. Battery Type 1072 1072 1073 - == 4.1 Battery Type==1237 +SDI-12-LB is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 1074 1074 1075 1075 1076 -SDI-12-LB is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>https://www.dropbox.com/sh/w9l2oa3ytpculph/AAAPtt-apH4lYfCj-2Y6lHvQa?dl=0]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 1077 - 1078 - 1079 1079 The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance. 1080 1080 1081 -[[image: 1675234124233-857.png]]1242 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1082 1082 1083 1083 1084 1084 Minimum Working Voltage for the SDI-12-LB: ... ... @@ -1086,25 +1086,31 @@ 1086 1086 SDI-12-LB: 2.45v ~~ 3.6v 1087 1087 1088 1088 1089 -== 4.2 Replace Battery == 1250 +1. 1251 +11. Replace Battery 1090 1090 1091 - 1092 1092 Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. 1093 1093 1094 1094 And make sure the positive and negative pins match. 1095 1095 1096 1096 1097 -== 4.3 Power Consumption Analyze == 1098 1098 1259 +1. 1260 +11. Power Consumption Analyze 1099 1099 1100 1100 Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 1101 1101 1264 + 1102 1102 Instruction to use as below: 1103 1103 1104 -(% style="color:blue" %)**Step 1:**(%%) Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0>>https://www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0]] 1105 1105 1106 - (% style="color:blue" %)**Step2:**(%%)Openand choose1268 +Step 1: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 1107 1107 1270 +[[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 1271 + 1272 + 1273 +Step 2: Open it and choose 1274 + 1108 1108 * Product Model 1109 1109 * Uplink Interval 1110 1110 * Working Mode ... ... @@ -1111,47 +1111,56 @@ 1111 1111 1112 1112 And the Life expectation in difference case will be shown on the right. 1113 1113 1281 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image037.png]] 1114 1114 1115 -[[image:1675234155374-163.png]] 1116 1116 1117 - 1118 1118 The battery related documents as below: 1119 1119 1120 -* [[Battery Dimension>>http s://www.dropbox.com/s/ox5g9njwjle7aw3/LSN50-Battery-Dimension.pdf?dl=0]],1121 -* [[Lithium-Thionyl Chloride Battery datasheet, Tech Spec>>http s://www.dropbox.com/sh/d4oyfnp8o94180o/AABQewCNSh5GPeQH86UxRgQQa?dl=0]]1122 -* [[Lithium-ion Battery-Capacitor datasheet>>http s://www.dropbox.com/s/791gjes2lcbfi1p/SPC_1520_datasheet.jpg?dl=0]], [[Tech Spec>>https://www.dropbox.com/s/4pkepr9qqqvtzf2/SPC1520%20Technical%20Specification20171123.pdf?dl=0]]1286 +* [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]], 1287 +* [[Lithium-Thionyl Chloride Battery>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/ER18505_datasheet-EN.pdf]] datasheet, [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/ER18505_datasheet_PM-ER18505-S-02-LF_EN.pdf]] 1288 +* [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]] 1123 1123 1124 -[[image:image-20230201145019-19.png]] 1290 +|((( 1291 +JST-XH-2P connector 1292 +))) 1125 1125 1294 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image038.png]] 1126 1126 1127 -=== 4.3.1 Battery Note === 1128 1128 1129 1129 1298 +1. 1299 +11. 1300 +111. Battery Note 1301 + 1130 1130 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 1131 1131 1132 1132 1133 -=== 4.3.2 Replace the battery === 1305 +1. 1306 +11. 1307 +111. Replace the battery 1134 1134 1309 +You can change the battery in the SDI-12-LB.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board. 1135 1135 1136 -You can change the battery in the SDI-12-LB.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board. 1137 1137 1138 -The default battery pack of SDI-12-LB includes a ER26500 plus super capacitor. If user can 't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)1312 +The default battery pack of SDI-12-LB includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 1139 1139 1140 1140 1141 -= 5. Remote Configure device = 1142 1142 1143 -== 5.1 Connect via BLE == 1144 1144 1145 1145 1146 -Please see this instruction for how to configure via BLE: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]] 1147 1147 1319 +1. Remote Configure device 1320 +11. Connect via BLE 1148 1148 1149 - ==5.2ATCommandSet==1322 +Please see this instruction for how to configure via BLE: 1150 1150 1324 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]] 1151 1151 1152 1152 1153 -= 6. OTA firmware update = 1327 +1. 1328 +11. AT Command Set 1154 1154 1330 +1. OTA firmware update 1155 1155 1156 1156 Please see this link for how to do OTA firmware update. 1157 1157 ... ... @@ -1158,69 +1158,35 @@ 1158 1158 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 1159 1159 1160 1160 1161 -= 7. FAQ = 1162 1162 1163 -== 7.1 How to use AT Command to access device? == 1164 1164 1165 1165 1166 -See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]] 1167 1167 1168 1168 1169 -== 7.2 How to update firmware via UART port? == 1170 1170 1171 1171 1172 -See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]] 1173 1173 1174 1174 1175 - == 7.3How to change the LoRa FrequencyBands/Region? ==1346 +1. Order Info 1176 1176 1348 +**Package Includes**: 1177 1177 1178 -You can follow the instructions for [[how to upgrade image>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]. 1179 -When downloading the images, choose the required image file for download. 1350 +* SDI-12-LB SDI-12 to LoRaWAN Converter 1180 1180 1352 +**Dimension and weight**: 1181 1181 1182 -= 8. Order Info = 1183 - 1184 - 1185 -((( 1186 -(% style="color:blue" %)**Part Number: SDI-12-LB-XXX** 1187 -))) 1188 - 1189 -((( 1190 -XXX: The default frequency band 1191 -))) 1192 - 1193 -((( 1194 -(% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 1195 -(% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band 1196 -(% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band 1197 -(% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band 1198 -(% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band 1199 -(% style="color:red" %)**US915**(%%): LoRaWAN US915 band 1200 -(% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1201 -(% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1202 -))) 1203 - 1204 - 1205 -= 9. Packing Info = 1206 - 1207 - 1208 -(% style="color:#037691" %)**Package Includes**: 1209 - 1210 -* SDI-12-LB SDI-12 to LoRaWAN Converter x 1 1211 - 1212 -(% style="color:#037691" %)**Dimension and weight**: 1213 - 1214 1214 * Device Size: cm 1215 1215 * Device Weight: g 1216 1216 * Package Size / pcs : cm 1217 1217 * Weight / pcs : g 1218 1218 1219 -= 10. Support = 1220 1220 1221 1221 1361 +1. Support 1362 + 1222 1222 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1364 +* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to 1223 1223 1224 - * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to[[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]1366 +[[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 1225 1225 1226 1226
- 1675216779406-595.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -59.2 KB - Content
- 1675234124233-857.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -75.8 KB - Content
- 1675234155374-163.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -138.2 KB - Content
- image-20230201145019-19.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -82.2 KB - Content
- image-20230201152430-20.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -16.5 KB - Content
- image-20230222143809-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -322.1 KB - Content