Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Mengting Qiu on 2025/07/03 15:42
From version 44.1
edited by Bei Jinggeng
on 2023/02/22 14:46
on 2023/02/22 14:46
Change comment:
There is no comment for this version
To version 46.1
edited by Bei Jinggeng
on 2023/03/20 10:20
on 2023/03/20 10:20
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -77,6 +77,8 @@ 77 77 (% style="color:#037691" %)**Common DC Characteristics:** 78 78 79 79 * Supply Voltage: 2.5v ~~ 3.6v 80 +* Support current: 5V 300mA 81 + 12V 100mA 80 80 * Operating Temperature: -40 ~~ 85°C 81 81 82 82 (% style="color:#037691" %)**LoRa Spec:** ... ... @@ -745,7 +745,7 @@ 745 745 746 746 The SDI-12-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: 747 747 748 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]] ]]750 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]] 749 749 750 750 751 751 == 2.6 Examples To Set SDI commands. == ... ... @@ -752,68 +752,69 @@ 752 752 753 753 === 2.6.1 Examples 1 === 754 754 757 + 755 755 COM port and SDI-12 sensor communication converted to SDI-12-LB and SDI-12 sensor communication. 756 756 757 757 [[image:image-20230222143809-1.png||height="564" width="729"]] 758 758 759 -1)The AT+COMMANDx command is applied to the red arrow part, and sends the SDI12 command to the SDI12 sensor: 760 760 761 - a.Sendthefirstcommand andget thefirstreply:763 +(% style="color:blue" %)**1) The AT+COMMANDx command is applied to the red arrow part, and sends the SDI12 command to the SDI12 sensor:** 762 762 763 - AT+COMMANDx=1I!,0,0,1765 +a. Send the first command and get the first reply: 764 764 765 - b.Sendthesecond command and getthesecond reply:767 +(% style="color:#037691" %)**AT+COMMANDx=1I!,0,0,1** 766 766 767 - AT+COMMANDx=2I!,0,0,1769 +b. Send the second command and get the second reply: 768 768 769 - c.Sendthethirdcommand and get the thirdreply:771 +(% style="color:#037691" %)**AT+COMMANDx=2I!,0,0,1** 770 770 771 - AT+COMMANDx=3I!,0,0,1773 +c. Send the third command and get the third reply: 772 772 773 - d.Sendthefourthcommand and get the fourthreply:775 +(% style="color:#037691" %)**AT+COMMANDx=3I!,0,0,1** 774 774 775 - AT+COMMANDx=4I!,0,0,1777 +d. Send the fourth command and get the fourth reply: 776 776 777 - e.Sendthefifthcommand plus the sixth command,get the sixth reply:779 +(% style="color:#037691" %)**AT+COMMANDx=4I!,0,0,1** 778 778 779 - AT+COMMANDx=1M!,2,1,1781 +e. Send the fifth command plus the sixth command, get the sixth reply: 780 780 781 - f.Sendtheseventh command plus theeighthcommand, get the eighth reply:783 +(% style="color:#037691" %)**AT+COMMANDx=1M!,2,1,1** 782 782 783 - AT+COMMANDx=2M!,2,1,1785 +f. Send the seventh command plus the eighth command, get the eighth reply: 784 784 785 - g.Sendtheninthcommand plus the tenth command, get the tenthreply:787 +(% style="color:#037691" %)**AT+COMMANDx=2M!,2,1,1** 786 786 787 - AT+COMMANDx=3M!,1,1,1789 +g. Send the ninth command plus the tenth command, get the tenth reply: 788 788 789 - h.Sendthe eleventhcommand plus the twelfth command, get the twelfthreply:791 +(% style="color:#037691" %)**AT+COMMANDx=3M!,1,1,1** 790 790 791 - AT+COMMANDx=4M!,1,1,1793 +h. Send the eleventh command plus the twelfth command, get the twelfth reply: 792 792 795 +(% style="color:#037691" %)**AT+COMMANDx=4M!,1,1,1** 793 793 794 -2) The AT+DATACUTx command is applied to the green arrow part, receiving and cut out data from the SDI12 sensor: 795 795 796 - a.Thefirst reply, all34characters: ”113TRUEBNERSMT100038220303182331<CR><LF>”798 +(% style="color:blue" %)**2) The AT+DATACUTx command is applied to the green arrow part, receiving and cut out data from the SDI12 sensor:** 797 797 798 - Cutout all characters:AT+ALLDATAMOD=1or AT+DATACUTx=34,2,1~~34;800 +a. The first reply, all 34 characters: ”113TRUEBNERSMT100038220303182331<CR><LF>” 799 799 802 +Cut out all characters: (% style="color:#037691" %)**AT+ALLDATAMOD=1 or AT+DATACUTx=34,2,1~~34**; 803 + 800 800 b. The sixth reply, all 31 characters:”1+19210+1.04+0.00+22.49+11.75<CR><LF>” 801 801 802 -Cut out all characters: AT+ALLDATAMOD=1 or AT+DATACUTx=31,2,1~~31; 806 +Cut out all characters: (% style="color:#037691" %)**AT+ALLDATAMOD=1 or AT+DATACUTx=31,2,1~~31**; 803 803 804 804 c. The eighth reply, all 31 characters:”2+18990+1.08+0.00+22.24+11.80<CR><LF>” 805 805 806 -Cut out all characters: AT+ALLDATAMOD=1 or AT+DATACUTx=31,2,1~~31; 810 +Cut out all characters: (% style="color:#037691" %)**AT+ALLDATAMOD=1 or AT+DATACUTx=31,2,1~~31**; 807 807 808 808 d. The tenth reply, all 15 characters:”3-2919.8+24.0<CR><LF>” 809 809 810 -Cut out all characters: AT+ALLDATAMOD=1 or AT+DATACUTx=15,2,1~~15; 814 +Cut out all characters: (% style="color:#037691" %)**AT+ALLDATAMOD=1 or AT+DATACUTx=15,2,1~~15**; 811 811 812 812 e. The twelfth reply, all 25 characters:”4+30.8+22.84+4.7+954.38<CR><LF>” 813 813 814 -Partial cut, the cut sensor address and the first two parameters:AT+DATACUTx=25,2,1~~12, cut out the character field ” 4+30.8+22.84”. 818 +Partial cut, the cut sensor address and the first two parameters:(% style="color:#037691" %)**AT+DATACUTx=25,2,1~~12, cut out the character field ” 4+30.8+22.84”**. 815 815 816 -== == 817 817 818 818 == 2.7 Frequency Plans == 819 819