... ... @@ -246,6 +246,7 @@
246 246  The following is the display information on the serial port and the server.
247 247  
248 248  
249 +
249 249  [[image:image-20230201091027-6.png]]
250 250  
251 251  
... ... @@ -252,7 +252,6 @@
252 252  [[image:image-20230201091027-7.png||height="261" width="1179"]]
253 253  
254 254  
255 -
256 256  ==== (% style="color:blue" %)**al!  ~-~- Get SDI-12 sensor Identification**(%%) ====
257 257  
258 258  
... ... @@ -261,7 +261,7 @@
261 261  
262 262  (% style="color:#037691" %)**Parameter:  **(%%)aa: ASCII value of SDI-12 sensor address in downlink or HEX value in AT Command)
263 263  
264 -(% style="color:blue" %)**Example :   **(%%)AT+ADDRI=0 ( Equal to downlink: 0x AA 00 30)
264 +(% style="color:blue" %)**Example :   **AT+ADDRI=0 ( Equal to downlink: 0x AA 00 30)
265 265  
266 266  
267 267  The following is the display information on the serial port and the server.
... ... @@ -297,7 +297,7 @@
297 297  
298 298  (% style="color:#037691" %)**cc**(%%): 1-9: Additional Measurement, 0: no additional measurement
299 299  
300 -(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)__**aD0!**__(%%) to get return.
300 +(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)**aD0!**(%%) to get return.
301 301  
302 302  
303 303  The following is the display information on the serial port and the server.
... ... @@ -334,7 +334,7 @@
334 334  
335 335  (% style="color:#037691" %)**cc**(%%): 1-9: Additional Measurement, 0: no additional measurement
336 336  
337 -(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)__**aD0!**__(%%)__ __to get return.
337 +(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)**aD0!**(%%) to get return.
338 338  
339 339  
340 340  The following is the display information on the serial port and the server.
... ... @@ -367,12 +367,13 @@
367 367  
368 368  (% style="color:#037691" %)**cc**(%%): 1-9: Additional Measurement, 0: no additional measurement
369 369  
370 -(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)__**aD0!**__(%%) to get return.
370 +(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)**aD0!**(%%) to get return.
371 371  
372 372  
373 373  The following is the display information on the serial port and the server.
374 374  
375 375  
376 +
376 376  [[image:image-20230201092208-14.png]]
377 377  
378 378  
... ... @@ -458,7 +458,7 @@
458 458  
459 459  (% style="color:red" %)**1** (%%) Check if return chars are printable char(0x20 ~~ 0x7E);
460 460  
461 -(% style="color:red" %)**2**(%%)  Check if there is return from SDI-12 sensor
462 +(% style="color:#red" %)**2**(%%)  Check if there is return from SDI-12 sensor
462 462  
463 463  (% style="color:red" %)**3** (%%) Check if return pass CRC check ( SDI-12 command var1 must include CRC request);
464 464  
... ... @@ -542,7 +542,7 @@
542 542  (% style="color:blue" %)**AT+ALLDATAMOD**(%%) will simply get all return and don't do CRC check as result for SDI-12 command. AT+DATACUTx command has higher priority, if AT+DATACUTx has been set, AT+ALLDATAMOD will be ignore for this SDI-12 command.
543 543  
544 544  
545 -(% style="color:#4f81bd" %)**For example: **(%%) as below photo, AT+ALLDATAMOD=1, but AT+DATACUT1 has been set, AT+DATACUT1 will be still effect the result.
546 +(% style="color:#4f81bd" %)**For example: ** as below photo, AT+ALLDATAMOD=1, but AT+DATACUT1 has been set, AT+DATACUT1 will be still effect the result.
546 546  
547 547  
548 548  [[image:1675215782925-448.png]]
... ... @@ -557,9 +557,9 @@
557 557  
558 558  (% style="color:#4f81bd" %)**AT+DATAUP=0**
559 559  
560 -Compose the uplink payload with value returns in sequence and send with **__A SIGNLE UPLINK__**.
561 +Compose the uplink payload with value returns in sequence and send with A SIGNLE UPLINK.
561 561  
562 -Final Payload is **__Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx__**
563 +Final Payload is Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx
563 563  
564 564  Where PAYVER is defined by AT+PAYVER, below is an example screen shot.
565 565  
... ... @@ -569,10 +569,12 @@
569 569  
570 570  (% style="color:#4f81bd" %)**AT+DATAUP=1**
571 571  
572 -Compose the uplink payload with value returns in sequence and send with **__Multiply UPLINKs__**.
573 +Compose the uplink payload with value returns in sequence and send with Multiply UPLINKs.
573 573  
574 -Final Payload is __**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**__
575 +Final Payload is
575 575  
577 +__**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**__
578 +
576 576  1. Battery Info (2 bytes): Battery voltage
577 577  1. PAYVER (1 byte): Defined by AT+PAYVER
578 578  1. PAYLOAD COUNT (1 byte): Total how many uplinks of this sampling.
... ... @@ -747,6 +747,8 @@
747 747  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]]]
748 748  
749 749  
753 +
754 +
750 750  == 2.6 Frequency Plans ==
751 751  
752 752  
... ... @@ -760,9 +760,8 @@
760 760  
761 761  **Firmware download link:**
762 762  
763 -[[https:~~/~~/www.dropbox.com/sh/qrbgbikb109lkiv/AACBR-v_ZhZAMengcY7Nsa1ja?dl=0>>https://www.dropbox.com/sh/qrbgbikb109lkiv/AACBR-v_ZhZAMengcY7Nsa1ja?dl=0]]
768 +[[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]]
764 764  
765 -
766 766  
767 767  = 3. Configure SDI-12-LB via AT Command or LoRaWAN Downlink =
768 768  
... ... @@ -820,6 +820,7 @@
820 820  * Example 1: Downlink Payload: 0100001E  ~/~/ Set Transmit Interval (TDC) = 30 seconds
821 821  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
822 822  
827 +
823 823  == 3.2 Set Interrupt Mode ==
824 824  
825 825  
... ... @@ -851,6 +851,7 @@
851 851  * Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
852 852  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
853 853  
859 +
854 854  == 3.3 Set the output time ==
855 855  
856 856  
... ... @@ -920,6 +920,7 @@
920 920  * Example 5: Downlink Payload: 070301F4  **~-~-->**  AT+12VT=500
921 921  * Example 6: Downlink Payload: 07030000  **~-~-->**  AT+12VT=0
922 922  
929 +
923 923  == 3.4 Set the all data mode ==
924 924  
925 925  
... ... @@ -942,6 +942,7 @@
942 942  * Example 1: Downlink Payload: AB 00  ~/~/  AT+ALLDATAMOD=0
943 943  * Example 2: Downlink Payload: AB 01  ~/~/  AT+ALLDATAMOD=1
944 944  
952 +
945 945  == 3.5 Set the splicing payload for uplink ==
946 946  
947 947  
... ... @@ -997,6 +997,7 @@
997 997  * Example 1: Downlink Payload: AE 01  ~/~/  AT+PAYVER=1
998 998  * Example 2: Downlink Payload: AE 05  ~/~/  AT+PAYVER=5
999 999  
1008 +
1000 1000  = 4. Battery & how to replace =
1001 1001  
1002 1002  == 4.1 Battery Type ==
... ... @@ -1144,6 +1144,7 @@
1144 1144  * Package Size / pcs : cm
1145 1145  * Weight / pcs : g
1146 1146  
1156 +
1147 1147  = 10. ​Support =
1148 1148  
1149 1149  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved