22 22  == 1.1 ​What is SDI-12 to LoRaWAN Converter ==
23 23  
24 24  
25 +(((
25 25  The Dragino (% style="color:blue" %)**SDI-12-LB**(%%) is a (% style="color:blue" %)**SDI-12 to LoRaWAN Converter **(%%)designed for Smart Agriculture solution.
27 +)))
26 26  
29 +(((
27 27  SDI-12 (Serial Digital Interface at 1200 baud) is an asynchronous [[serial communications>>url:https://en.wikipedia.org/wiki/Serial_communication]] protocol for intelligent sensors that monitor environment data. SDI-12 protocol is widely used in Agriculture sensor and Weather Station sensors.
31 +)))
28 28  
33 +(((
29 29  SDI-12-LB has SDI-12 interface and support 12v output to power external SDI-12 sensor. It can get the environment data from SDI-12 sensor and sends out the data via LoRaWAN wireless protocol.
35 +)))
30 30  
37 +(((
31 31  The LoRa wireless technology used in SDI-12-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
39 +)))
32 32  
41 +(((
33 33  SDI-12-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
43 +)))
34 34  
45 +(((
35 35  Each SDI-12-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
47 +)))
36 36  
37 37  
38 38  [[image:image-20230201084414-1.png||height="464" width="1108"]]
39 39  
40 40  
41 -
42 -
43 43  == ​1.2 Features ==
44 44  
45 45  
... ... @@ -542,7 +542,7 @@
542 542  (% style="color:blue" %)**AT+ALLDATAMOD**(%%) will simply get all return and don't do CRC check as result for SDI-12 command. AT+DATACUTx command has higher priority, if AT+DATACUTx has been set, AT+ALLDATAMOD will be ignore for this SDI-12 command.
543 543  
544 544  
545 -(% style="color:#4f81bd" %)**For example: ** as below photo, AT+ALLDATAMOD=1, but AT+DATACUT1 has been set, AT+DATACUT1 will be still effect the result.
555 +(% style="color:#4f81bd" %)**For example: **(%%) as below photo, AT+ALLDATAMOD=1, but AT+DATACUT1 has been set, AT+DATACUT1 will be still effect the result.
546 546  
547 547  
548 548  [[image:1675215782925-448.png]]
... ... @@ -557,9 +557,9 @@
557 557  
558 558  (% style="color:#4f81bd" %)**AT+DATAUP=0**
559 559  
560 -Compose the uplink payload with value returns in sequence and send with A SIGNLE UPLINK.
570 +Compose the uplink payload with value returns in sequence and send with **__A SIGNLE UPLINK__**.
561 561  
562 -Final Payload is Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx
572 +Final Payload is **__Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx__**
563 563  
564 564  Where PAYVER is defined by AT+PAYVER, below is an example screen shot.
565 565  
... ... @@ -569,12 +569,10 @@
569 569  
570 570  (% style="color:#4f81bd" %)**AT+DATAUP=1**
571 571  
572 -Compose the uplink payload with value returns in sequence and send with Multiply UPLINKs.
582 +Compose the uplink payload with value returns in sequence and send with **__Multiply UPLINKs__**.
573 573  
574 -Final Payload is
584 +Final Payload is __**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**__
575 575  
576 -__**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**__
577 -
578 578  1. Battery Info (2 bytes): Battery voltage
579 579  1. PAYVER (1 byte): Defined by AT+PAYVER
580 580  1. PAYLOAD COUNT (1 byte): Total how many uplinks of this sampling.
... ... @@ -749,8 +749,6 @@
749 749  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]]]
750 750  
751 751  
752 -
753 -
754 754  == 2.6 Frequency Plans ==
755 755  
756 756  
... ... @@ -764,8 +764,9 @@
764 764  
765 765  **Firmware download link:**
766 766  
767 -[[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]]
773 +[[https:~~/~~/www.dropbox.com/sh/qrbgbikb109lkiv/AACBR-v_ZhZAMengcY7Nsa1ja?dl=0>>https://www.dropbox.com/sh/qrbgbikb109lkiv/AACBR-v_ZhZAMengcY7Nsa1ja?dl=0]]
768 768  
775 +
769 769  
770 770  = 3. Configure SDI-12-LB via AT Command or LoRaWAN Downlink =
771 771  
... ... @@ -1128,11 +1128,6 @@
1128 1128  (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1129 1129  
1130 1130  