<
From version < 41.6 >
edited by Xiaoling
on 2023/02/01 15:29
To version < 41.12 >
edited by Xiaoling
on 2023/02/01 16:36
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -38,8 +38,6 @@
38 38  [[image:image-20230201084414-1.png||height="464" width="1108"]]
39 39  
40 40  
41 -
42 -
43 43  == ​1.2 Features ==
44 44  
45 45  
... ... @@ -542,7 +542,7 @@
542 542  (% style="color:blue" %)**AT+ALLDATAMOD**(%%) will simply get all return and don't do CRC check as result for SDI-12 command. AT+DATACUTx command has higher priority, if AT+DATACUTx has been set, AT+ALLDATAMOD will be ignore for this SDI-12 command.
543 543  
544 544  
545 -(% style="color:#4f81bd" %)**For example: ** as below photo, AT+ALLDATAMOD=1, but AT+DATACUT1 has been set, AT+DATACUT1 will be still effect the result.
543 +(% style="color:#4f81bd" %)**For example: **(%%) as below photo, AT+ALLDATAMOD=1, but AT+DATACUT1 has been set, AT+DATACUT1 will be still effect the result.
546 546  
547 547  
548 548  [[image:1675215782925-448.png]]
... ... @@ -557,9 +557,9 @@
557 557  
558 558  (% style="color:#4f81bd" %)**AT+DATAUP=0**
559 559  
560 -Compose the uplink payload with value returns in sequence and send with A SIGNLE UPLINK.
558 +Compose the uplink payload with value returns in sequence and send with **__A SIGNLE UPLINK__**.
561 561  
562 -Final Payload is Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx
560 +Final Payload is **__Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx__**
563 563  
564 564  Where PAYVER is defined by AT+PAYVER, below is an example screen shot.
565 565  
... ... @@ -569,12 +569,10 @@
569 569  
570 570  (% style="color:#4f81bd" %)**AT+DATAUP=1**
571 571  
572 -Compose the uplink payload with value returns in sequence and send with Multiply UPLINKs.
570 +Compose the uplink payload with value returns in sequence and send with **__Multiply UPLINKs__**.
573 573  
574 -Final Payload is
572 +Final Payload is __**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**__
575 575  
576 -__**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**__
577 -
578 578  1. Battery Info (2 bytes): Battery voltage
579 579  1. PAYVER (1 byte): Defined by AT+PAYVER
580 580  1. PAYLOAD COUNT (1 byte): Total how many uplinks of this sampling.
... ... @@ -749,8 +749,6 @@
749 749  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]]]
750 750  
751 751  
752 -
753 -
754 754  == 2.6 Frequency Plans ==
755 755  
756 756  
... ... @@ -764,8 +764,9 @@
764 764  
765 765  **Firmware download link:**
766 766  
767 -[[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]]
761 +[[https:~~/~~/www.dropbox.com/sh/qrbgbikb109lkiv/AACBR-v_ZhZAMengcY7Nsa1ja?dl=0>>https://www.dropbox.com/sh/qrbgbikb109lkiv/AACBR-v_ZhZAMengcY7Nsa1ja?dl=0]]
768 768  
763 +
769 769  
770 770  = 3. Configure SDI-12-LB via AT Command or LoRaWAN Downlink =
771 771  
... ... @@ -1128,11 +1128,6 @@
1128 1128  (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1129 1129  
1130 1130  
1131 -
1132 -
1133 -
1134 -
1135 -
1136 1136  = 9. Packing Info =
1137 1137  
1138 1138  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0