From version < 41.4 >
edited by Xiaoling
on 2023/02/01 15:27
To version < 41.13 >
edited by Xiaoling
on 2023/02/01 16:37
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -22,24 +22,34 @@
22 22  == 1.1 ​What is SDI-12 to LoRaWAN Converter ==
23 23  
24 24  
25 +(((
25 25  The Dragino (% style="color:blue" %)**SDI-12-LB**(%%) is a (% style="color:blue" %)**SDI-12 to LoRaWAN Converter **(%%)designed for Smart Agriculture solution.
27 +)))
26 26  
29 +(((
27 27  SDI-12 (Serial Digital Interface at 1200 baud) is an asynchronous [[serial communications>>url:https://en.wikipedia.org/wiki/Serial_communication]] protocol for intelligent sensors that monitor environment data. SDI-12 protocol is widely used in Agriculture sensor and Weather Station sensors.
31 +)))
28 28  
33 +(((
29 29  SDI-12-LB has SDI-12 interface and support 12v output to power external SDI-12 sensor. It can get the environment data from SDI-12 sensor and sends out the data via LoRaWAN wireless protocol.
35 +)))
30 30  
37 +(((
31 31  The LoRa wireless technology used in SDI-12-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
39 +)))
32 32  
41 +(((
33 33  SDI-12-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
43 +)))
34 34  
45 +(((
35 35  Each SDI-12-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
47 +)))
36 36  
37 37  
38 38  [[image:image-20230201084414-1.png||height="464" width="1108"]]
39 39  
40 40  
41 -
42 -
43 43  == ​1.2 Features ==
44 44  
45 45  
... ... @@ -297,7 +297,7 @@
297 297  
298 298  (% style="color:#037691" %)**cc**(%%): 1-9: Additional Measurement, 0: no additional measurement
299 299  
300 -(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)**aD0!**(%%) to get return.
310 +(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)__**aD0!**__(%%) to get return.
301 301  
302 302  
303 303  The following is the display information on the serial port and the server.
... ... @@ -334,7 +334,7 @@
334 334  
335 335  (% style="color:#037691" %)**cc**(%%): 1-9: Additional Measurement, 0: no additional measurement
336 336  
337 -(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)**aD0!**(%%) to get return.
347 +(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)__**aD0!**__(%%)__ __to get return.
338 338  
339 339  
340 340  The following is the display information on the serial port and the server.
... ... @@ -367,13 +367,12 @@
367 367  
368 368  (% style="color:#037691" %)**cc**(%%): 1-9: Additional Measurement, 0: no additional measurement
369 369  
370 -(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)**aD0!**(%%) to get return.
380 +(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)__**aD0!**__(%%) to get return.
371 371  
372 372  
373 373  The following is the display information on the serial port and the server.
374 374  
375 375  
376 -
377 377  [[image:image-20230201092208-14.png]]
378 378  
379 379  
... ... @@ -459,7 +459,7 @@
459 459  
460 460  (% style="color:red" %)**1** (%%) Check if return chars are printable char(0x20 ~~ 0x7E);
461 461  
462 -(% style="color:#red" %)**2**(%%)  Check if there is return from SDI-12 sensor
471 +(% style="color:red" %)**2**(%%)  Check if there is return from SDI-12 sensor
463 463  
464 464  (% style="color:red" %)**3** (%%) Check if return pass CRC check ( SDI-12 command var1 must include CRC request);
465 465  
... ... @@ -543,7 +543,7 @@
543 543  (% style="color:blue" %)**AT+ALLDATAMOD**(%%) will simply get all return and don't do CRC check as result for SDI-12 command. AT+DATACUTx command has higher priority, if AT+DATACUTx has been set, AT+ALLDATAMOD will be ignore for this SDI-12 command.
544 544  
545 545  
546 -(% style="color:#4f81bd" %)**For example: ** as below photo, AT+ALLDATAMOD=1, but AT+DATACUT1 has been set, AT+DATACUT1 will be still effect the result.
555 +(% style="color:#4f81bd" %)**For example: **(%%) as below photo, AT+ALLDATAMOD=1, but AT+DATACUT1 has been set, AT+DATACUT1 will be still effect the result.
547 547  
548 548  
549 549  [[image:1675215782925-448.png]]
... ... @@ -558,9 +558,9 @@
558 558  
559 559  (% style="color:#4f81bd" %)**AT+DATAUP=0**
560 560  
561 -Compose the uplink payload with value returns in sequence and send with A SIGNLE UPLINK.
570 +Compose the uplink payload with value returns in sequence and send with **__A SIGNLE UPLINK__**.
562 562  
563 -Final Payload is Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx
572 +Final Payload is **__Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx__**
564 564  
565 565  Where PAYVER is defined by AT+PAYVER, below is an example screen shot.
566 566  
... ... @@ -570,12 +570,10 @@
570 570  
571 571  (% style="color:#4f81bd" %)**AT+DATAUP=1**
572 572  
573 -Compose the uplink payload with value returns in sequence and send with Multiply UPLINKs.
582 +Compose the uplink payload with value returns in sequence and send with **__Multiply UPLINKs__**.
574 574  
575 -Final Payload is
584 +Final Payload is __**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**__
576 576  
577 -__**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**__
578 -
579 579  1. Battery Info (2 bytes): Battery voltage
580 580  1. PAYVER (1 byte): Defined by AT+PAYVER
581 581  1. PAYLOAD COUNT (1 byte): Total how many uplinks of this sampling.
... ... @@ -750,8 +750,6 @@
750 750  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]]]
751 751  
752 752  
753 -
754 -
755 755  == 2.6 Frequency Plans ==
756 756  
757 757  
... ... @@ -765,8 +765,9 @@
765 765  
766 766  **Firmware download link:**
767 767  
768 -[[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]]
773 +[[https:~~/~~/www.dropbox.com/sh/qrbgbikb109lkiv/AACBR-v_ZhZAMengcY7Nsa1ja?dl=0>>https://www.dropbox.com/sh/qrbgbikb109lkiv/AACBR-v_ZhZAMengcY7Nsa1ja?dl=0]]
769 769  
775 +
770 770  
771 771  = 3. Configure SDI-12-LB via AT Command or LoRaWAN Downlink =
772 772  
... ... @@ -1129,11 +1129,6 @@
1129 1129  (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1130 1130  
1131 1131  
1132 -
1133 -
1134 -
1135 -
1136 -
1137 1137  = 9. Packing Info =
1138 1138  
1139 1139  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0