Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Xiaoling on 2025/04/25 08:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -38,8 +38,6 @@ 38 38 [[image:image-20230201084414-1.png||height="464" width="1108"]] 39 39 40 40 41 - 42 - 43 43 == 1.2 Features == 44 44 45 45 ... ... @@ -297,7 +297,7 @@ 297 297 298 298 (% style="color:#037691" %)**cc**(%%): 1-9: Additional Measurement, 0: no additional measurement 299 299 300 -(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)**aD0!**(%%) to get return. 298 +(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)__**aD0!**__(%%) to get return. 301 301 302 302 303 303 The following is the display information on the serial port and the server. ... ... @@ -334,7 +334,7 @@ 334 334 335 335 (% style="color:#037691" %)**cc**(%%): 1-9: Additional Measurement, 0: no additional measurement 336 336 337 -(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)**aD0!**(%%) to get return. 335 +(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)__**aD0!**__(%%)__ __to get return. 338 338 339 339 340 340 The following is the display information on the serial port and the server. ... ... @@ -367,13 +367,12 @@ 367 367 368 368 (% style="color:#037691" %)**cc**(%%): 1-9: Additional Measurement, 0: no additional measurement 369 369 370 -(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)**aD0!**(%%) to get return. 368 +(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)__**aD0!**__(%%) to get return. 371 371 372 372 373 373 The following is the display information on the serial port and the server. 374 374 375 375 376 - 377 377 [[image:image-20230201092208-14.png]] 378 378 379 379 ... ... @@ -459,7 +459,7 @@ 459 459 460 460 (% style="color:red" %)**1** (%%) Check if return chars are printable char(0x20 ~~ 0x7E); 461 461 462 -(% style="color: #red" %)**2**(%%) Check if there is return from SDI-12 sensor459 +(% style="color:red" %)**2**(%%) Check if there is return from SDI-12 sensor 463 463 464 464 (% style="color:red" %)**3** (%%) Check if return pass CRC check ( SDI-12 command var1 must include CRC request); 465 465 ... ... @@ -543,7 +543,7 @@ 543 543 (% style="color:blue" %)**AT+ALLDATAMOD**(%%) will simply get all return and don't do CRC check as result for SDI-12 command. AT+DATACUTx command has higher priority, if AT+DATACUTx has been set, AT+ALLDATAMOD will be ignore for this SDI-12 command. 544 544 545 545 546 -(% style="color:#4f81bd" %)**For example: ** as below photo, AT+ALLDATAMOD=1, but AT+DATACUT1 has been set, AT+DATACUT1 will be still effect the result. 543 +(% style="color:#4f81bd" %)**For example: **(%%) as below photo, AT+ALLDATAMOD=1, but AT+DATACUT1 has been set, AT+DATACUT1 will be still effect the result. 547 547 548 548 549 549 [[image:1675215782925-448.png]] ... ... @@ -558,9 +558,9 @@ 558 558 559 559 (% style="color:#4f81bd" %)**AT+DATAUP=0** 560 560 561 -Compose the uplink payload with value returns in sequence and send with A SIGNLE UPLINK. 558 +Compose the uplink payload with value returns in sequence and send with **__A SIGNLE UPLINK__**. 562 562 563 -Final Payload is Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx 560 +Final Payload is **__Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx__** 564 564 565 565 Where PAYVER is defined by AT+PAYVER, below is an example screen shot. 566 566 ... ... @@ -570,12 +570,10 @@ 570 570 571 571 (% style="color:#4f81bd" %)**AT+DATAUP=1** 572 572 573 -Compose the uplink payload with value returns in sequence and send with Multiply UPLINKs. 570 +Compose the uplink payload with value returns in sequence and send with **__Multiply UPLINKs__**. 574 574 575 -Final Payload is 572 +Final Payload is __**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**__ 576 576 577 -__**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**__ 578 - 579 579 1. Battery Info (2 bytes): Battery voltage 580 580 1. PAYVER (1 byte): Defined by AT+PAYVER 581 581 1. PAYLOAD COUNT (1 byte): Total how many uplinks of this sampling. ... ... @@ -750,8 +750,6 @@ 750 750 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]]] 751 751 752 752 753 - 754 - 755 755 == 2.6 Frequency Plans == 756 756 757 757 ... ... @@ -765,8 +765,9 @@ 765 765 766 766 **Firmware download link:** 767 767 768 -[[https:~~/~~/www.dropbox.com/sh/g f1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]]761 +[[https:~~/~~/www.dropbox.com/sh/qrbgbikb109lkiv/AACBR-v_ZhZAMengcY7Nsa1ja?dl=0>>https://www.dropbox.com/sh/qrbgbikb109lkiv/AACBR-v_ZhZAMengcY7Nsa1ja?dl=0]] 769 769 763 + 770 770 771 771 = 3. Configure SDI-12-LB via AT Command or LoRaWAN Downlink = 772 772 ... ... @@ -1129,11 +1129,6 @@ 1129 1129 (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1130 1130 1131 1131 1132 - 1133 - 1134 - 1135 - 1136 - 1137 1137 = 9. Packing Info = 1138 1138 1139 1139