... ... @@ -297,7 +297,7 @@
297 297  
298 298  (% style="color:#037691" %)**cc**(%%): 1-9: Additional Measurement, 0: no additional measurement
299 299  
300 -(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)**aD0!**(%%) to get return.
300 +(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)__**aD0!**__(%%) to get return.
301 301  
302 302  
303 303  The following is the display information on the serial port and the server.
... ... @@ -334,7 +334,7 @@
334 334  
335 335  (% style="color:#037691" %)**cc**(%%): 1-9: Additional Measurement, 0: no additional measurement
336 336  
337 -(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)**aD0!**(%%) to get return.
337 +(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)__**aD0!**__(%%)__ __to get return.
338 338  
339 339  
340 340  The following is the display information on the serial port and the server.
... ... @@ -367,13 +367,12 @@
367 367  
368 368  (% style="color:#037691" %)**cc**(%%): 1-9: Additional Measurement, 0: no additional measurement
369 369  
370 -(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)**aD0!**(%%) to get return.
370 +(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)__**aD0!**__(%%) to get return.
371 371  
372 372  
373 373  The following is the display information on the serial port and the server.
374 374  
375 375  
376 -
377 377  [[image:image-20230201092208-14.png]]
378 378  
379 379  
... ... @@ -459,7 +459,7 @@
459 459  
460 460  (% style="color:red" %)**1** (%%) Check if return chars are printable char(0x20 ~~ 0x7E);
461 461  
462 -(% style="color:#red" %)**2**(%%)  Check if there is return from SDI-12 sensor
461 +(% style="color:red" %)**2**(%%)  Check if there is return from SDI-12 sensor
463 463  
464 464  (% style="color:red" %)**3** (%%) Check if return pass CRC check ( SDI-12 command var1 must include CRC request);
465 465  
... ... @@ -543,7 +543,7 @@
543 543  (% style="color:blue" %)**AT+ALLDATAMOD**(%%) will simply get all return and don't do CRC check as result for SDI-12 command. AT+DATACUTx command has higher priority, if AT+DATACUTx has been set, AT+ALLDATAMOD will be ignore for this SDI-12 command.
544 544  
545 545  
546 -(% style="color:#4f81bd" %)**For example: ** as below photo, AT+ALLDATAMOD=1, but AT+DATACUT1 has been set, AT+DATACUT1 will be still effect the result.
545 +(% style="color:#4f81bd" %)**For example: **(%%) as below photo, AT+ALLDATAMOD=1, but AT+DATACUT1 has been set, AT+DATACUT1 will be still effect the result.
547 547  
548 548  
549 549  [[image:1675215782925-448.png]]
... ... @@ -558,9 +558,9 @@
558 558  
559 559  (% style="color:#4f81bd" %)**AT+DATAUP=0**
560 560  
561 -Compose the uplink payload with value returns in sequence and send with A SIGNLE UPLINK.
560 +Compose the uplink payload with value returns in sequence and send with **__A SIGNLE UPLINK__**.
562 562  
563 -Final Payload is Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx
562 +Final Payload is **__Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx__**
564 564  
565 565  Where PAYVER is defined by AT+PAYVER, below is an example screen shot.
566 566  
... ... @@ -570,12 +570,10 @@
570 570  
571 571  (% style="color:#4f81bd" %)**AT+DATAUP=1**
572 572  
573 -Compose the uplink payload with value returns in sequence and send with Multiply UPLINKs.
572 +Compose the uplink payload with value returns in sequence and send with **__Multiply UPLINKs__**.
574 574  
575 -Final Payload is
574 +Final Payload is __**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**__
576 576  
577 -__**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**__
578 -
579 579  1. Battery Info (2 bytes): Battery voltage
580 580  1. PAYVER (1 byte): Defined by AT+PAYVER
581 581  1. PAYLOAD COUNT (1 byte): Total how many uplinks of this sampling.
... ... @@ -750,8 +750,6 @@
750 750  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]]]
751 751  
752 752  
753 -
754 -
755 755  == 2.6 Frequency Plans ==
756 756  
757 757  
... ... @@ -765,8 +765,9 @@
765 765  
766 766  **Firmware download link:**
767 767  
768 -[[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]]
763 +[[https:~~/~~/www.dropbox.com/sh/qrbgbikb109lkiv/AACBR-v_ZhZAMengcY7Nsa1ja?dl=0>>https://www.dropbox.com/sh/qrbgbikb109lkiv/AACBR-v_ZhZAMengcY7Nsa1ja?dl=0]]
769 769  
765 +
770 770  
771 771  = 3. Configure SDI-12-LB via AT Command or LoRaWAN Downlink =
772 772  
... ... @@ -1129,11 +1129,6 @@
1129 1129  (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1130 1130  
1131 1131  
1132 -
1133 -
1134 -
1135 -
1136 -
1137 1137  = 9. Packing Info =
1138 1138  
1139 1139  