Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Mengting Qiu on 2025/07/03 15:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -17,39 +17,30 @@ 17 17 18 18 19 19 20 + 20 20 = 1. Introduction = 21 21 22 22 == 1.1 What is SDI-12 to LoRaWAN Converter == 23 23 24 24 25 -((( 26 -The Dragino (% style="color:blue" %)**SDI-12-LB**(%%) is a (% style="color:blue" %)**SDI-12 to LoRaWAN Converter **(%%)designed for Smart Agriculture solution. 27 -))) 26 +The Dragino **(% style="color:blue" %)SDI-12-LB**(%%) is a **(% style="color:blue" %)SDI-12 to LoRaWAN Converter **(%%)designed for Smart Agriculture solution. 28 28 29 -((( 30 30 SDI-12 (Serial Digital Interface at 1200 baud) is an asynchronous [[serial communications>>url:https://en.wikipedia.org/wiki/Serial_communication]] protocol for intelligent sensors that monitor environment data. SDI-12 protocol is widely used in Agriculture sensor and Weather Station sensors. 31 -))) 32 32 33 -((( 34 34 SDI-12-LB has SDI-12 interface and support 12v output to power external SDI-12 sensor. It can get the environment data from SDI-12 sensor and sends out the data via LoRaWAN wireless protocol. 35 -))) 36 36 37 -((( 38 38 The LoRa wireless technology used in SDI-12-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 39 -))) 40 40 41 -((( 42 -SDI-12-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 43 -))) 34 +SDI-12-LB is powered by **(% style="color:blue" %)8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 44 44 45 -((( 46 46 Each SDI-12-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 47 -))) 48 48 49 49 50 50 [[image:image-20230201084414-1.png||height="464" width="1108"]] 51 51 52 52 42 + 43 + 53 53 == 1.2 Features == 54 54 55 55 ... ... @@ -66,22 +66,21 @@ 66 66 * 8500mAh Battery for long term use 67 67 68 68 69 - 70 70 == 1.3 Specification == 71 71 72 72 73 -(% style="color:#037691" %) **Micro Controller:**63 +**(% style="color:#037691" %)Micro Controller:** 74 74 75 75 * MCU: 48Mhz ARM 76 76 * Flash: 256KB 77 77 * RAM: 64KB 78 78 79 -(% style="color:#037691" %) **Common DC Characteristics:**69 +**(% style="color:#037691" %)Common DC Characteristics:** 80 80 81 81 * Supply Voltage: 2.5v ~~ 3.6v 82 82 * Operating Temperature: -40 ~~ 85°C 83 83 84 -(% style="color:#037691" %) **LoRa Spec:**74 +**(% style="color:#037691" %)LoRa Spec:** 85 85 86 86 * Frequency Range, Band 1 (HF): 862 ~~ 1020 Mhz 87 87 * Max +22 dBm constant RF output vs. ... ... @@ -88,19 +88,19 @@ 88 88 * RX sensitivity: down to -139 dBm. 89 89 * Excellent blocking immunity 90 90 91 -(% style="color:#037691" %) **Current Input Measuring :**81 +**(% style="color:#037691" %)Current Input Measuring :** 92 92 93 93 * Range: 0 ~~ 20mA 94 94 * Accuracy: 0.02mA 95 95 * Resolution: 0.001mA 96 96 97 -(% style="color:#037691" %) **Voltage Input Measuring:**87 +**(% style="color:#037691" %)Voltage Input Measuring:** 98 98 99 99 * Range: 0 ~~ 30v 100 100 * Accuracy: 0.02v 101 101 * Resolution: 0.001v 102 102 103 -(% style="color:#037691" %) **Battery:**93 +**(% style="color:#037691" %)Battery:** 104 104 105 105 * Li/SOCI2 un-chargeable battery 106 106 * Capacity: 8500mAh ... ... @@ -108,13 +108,12 @@ 108 108 * Max continuously current: 130mA 109 109 * Max boost current: 2A, 1 second 110 110 111 -(% style="color:#037691" %) **Power Consumption**101 +**(% style="color:#037691" %)Power Consumption** 112 112 113 113 * Sleep Mode: 5uA @ 3.3v 114 114 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 115 115 116 116 117 - 118 118 == 1.4 Connect to SDI-12 Sensor == 119 119 120 120 ... ... @@ -125,9 +125,9 @@ 125 125 == 1.5 Sleep mode and working mode == 126 126 127 127 128 -(% style="color:blue" %) **Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life.117 +**(% style="color:blue" %)Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life. 129 129 130 -(% style="color:blue" %) **Working Mode: **(%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode.119 +**(% style="color:blue" %)Working Mode: **(%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode. 131 131 132 132 133 133 == 1.6 Button & LEDs == ... ... @@ -136,21 +136,21 @@ 136 136 [[image:1675212633011-651.png]] 137 137 138 138 128 + 139 139 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 140 -|=(% style="width: 167px;" %)**Behavior on ACT**|=(% style="width: 1 09px;" %)**Function**|=(% style="width: 231px;" %)**Action**141 -|(% style="width:167px" %)Pressing ACT between 1s < time < 3s|(% style="width:1 09px" %)Send an uplink|(% style="width:231px" %)(((130 +|=(% style="width: 167px;" %)**Behavior on ACT**|=(% style="width: 117px;" %)**Function**|=(% style="width: 225px;" %)**Action** 131 +|(% style="width:167px" %)Pressing ACT between 1s < time < 3s|(% style="width:117px" %)Send an uplink|(% style="width:225px" %)((( 142 142 If sensor is already Joined to LoRaWAN network, sensor will send an uplink packet, (% style="color:blue" %)**blue led** (%%)will blink once. 143 143 Meanwhile, BLE module will be active and user can connect via BLE to configure device. 144 144 ))) 145 -|(% style="width:167px" %)Pressing ACT for more than 3s|(% style="width:1 09px" %)Active Device|(% style="width:231px" %)(((135 +|(% style="width:167px" %)Pressing ACT for more than 3s|(% style="width:117px" %)Active Device|(% style="width:225px" %)((( 146 146 (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:#037691" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. 147 147 (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 148 148 Once sensor is active, BLE module will be active and user can connect via BLE to configure device, no matter if device join or not join LoRaWAN network. 149 149 ))) 150 -|(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:1 09px" %)Deactivate Device|(% style="width:231px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode.140 +|(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode. 151 151 152 152 153 - 154 154 == 1.7 Pin Mapping == 155 155 156 156 ... ... @@ -186,7 +186,7 @@ 186 186 == 2.1 How it works == 187 187 188 188 189 -The SDI-12-LB is configured as (% style="color:#037691" %) **LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and activate the SDI-12-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.178 +The SDI-12-LB is configured as **(% style="color:#037691" %)LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and activate the SDI-12-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes. 190 190 191 191 192 192 == 2.2 Quick guide to connect to LoRaWAN server (OTAA) == ... ... @@ -201,47 +201,51 @@ 201 201 The LPS8V2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server. 202 202 203 203 204 -(% style="color:blue" %) **Step 1**(%%): Create a device in TTN with the OTAA keys from SDI-12-LB.193 +**(% style="color:blue" %)Step 1**(%%): Create a device in TTN with the OTAA keys from SDI-12-LB. 205 205 206 206 Each SDI-12-LB is shipped with a sticker with the default device EUI as below: 207 207 208 208 209 -[[image:image-20230 201152430-20.jpeg]]198 +[[image:image-20230131134744-2.jpeg]] 210 210 211 211 201 + 202 + 203 + 212 212 You can enter this key in the LoRaWAN Server portal. Below is TTN screen shot: 213 213 214 214 215 -(% style="color:blue" %) **Register the device**207 +**(% style="color:blue" %)Register the device** 216 216 217 217 [[image:1675213652444-622.png]] 218 218 219 219 220 -(% style="color:blue" %) **Add APP EUI and DEV EUI**212 +**(% style="color:blue" %)Add APP EUI and DEV EUI** 221 221 222 222 223 223 [[image:1675213661769-223.png]] 224 224 225 225 226 -(% style="color:blue" %) **Add APP EUI in the application**218 +**(% style="color:blue" %)Add APP EUI in the application** 227 227 228 228 229 229 [[image:1675213675852-577.png]] 230 230 231 231 232 -(% style="color:blue" %) **Add APP KEY**224 +**(% style="color:blue" %)Add APP KEY** 233 233 234 234 [[image:1675213686734-883.png]] 235 235 236 236 237 -(% style="color:blue" %) **Step 2**(%%): Activate on SDI-12-LB229 +**(% style="color:blue" %)Step 2**(%%): Activate on SDI-12-LB 238 238 239 239 240 240 Press the button for 5 seconds to activate the SDI-12-LB. 241 241 242 -(% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode** (%%)for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 243 243 235 +**(% style="color:green" %)Green led**(%%) will fast blink 5 times, device will enter **(% style="color:blue" %)OTA mode** (%%)for 3 seconds. And then start to JOIN LoRaWAN network. **(% style="color:green" %)Green led**(%%) will solidly turn on for 5 seconds after joined in network. 244 244 237 + 245 245 [[image:1675213704414-644.png]] 246 246 247 247 ... ... @@ -261,6 +261,7 @@ 261 261 The following is the display information on the serial port and the server. 262 262 263 263 257 + 264 264 [[image:image-20230201091027-6.png]] 265 265 266 266 ... ... @@ -267,16 +267,15 @@ 267 267 [[image:image-20230201091027-7.png||height="261" width="1179"]] 268 268 269 269 264 +==== **(% style="color:blue" %)al! ~-~- Get SDI-12 sensor Identification** ==== 270 270 271 -==== (% style="color:blue" %)**al! ~-~- Get SDI-12 sensor Identification**(%%) ==== 272 272 273 - 274 274 * AT Command: AT+ADDRI=aa 275 275 * LoRaWAN Downlink(prefix 0xAA00): AA 00 aa 276 276 277 -(% style="color:#037691" %) **Parameter: **(%%)aa: ASCII value of SDI-12 sensor address in downlink or HEX value in AT Command)270 +**(% style="color:#037691" %)Parameter: **(%%)aa: ASCII value of SDI-12 sensor address in downlink or HEX value in AT Command) 278 278 279 -(% style="color:blue" %) **Example : **(%%)AT+ADDRI=0 ( Equal to downlink: 0x AA 00 30)272 +**(% style="color:blue" %)Example : **AT+ADDRI=0 ( Equal to downlink: 0x AA 00 30) 280 280 281 281 282 282 The following is the display information on the serial port and the server. ... ... @@ -288,16 +288,16 @@ 288 288 [[image:image-20230201091257-9.png||height="225" width="1242"]] 289 289 290 290 291 -==== (% style="color:blue" %) **aM!,aMC!, aM1!- aM9!, aMC1!- aMC9!**(%%)====284 +==== **(% style="color:blue" %)aM!,aMC!, aM1!- aM9!, aMC1!- aMC9!** ==== 292 292 293 293 294 -(% style="color:red" %) **aM! **(%%): Start Non-Concurrent Measurement287 +**(% style="color:red" %)aM! **(%%): Start Non-Concurrent Measurement 295 295 296 -(% style="color:red" %) **aMC! **(%%): Start Non-Concurrent Measurement – Request CRC289 +**(% style="color:red" %)aMC! **(%%): Start Non-Concurrent Measurement – Request CRC 297 297 298 -(% style="color:red" %) **aM1!- aM9! **(%%): Additional Measurements291 +**(% style="color:red" %)aM1!- aM9! **(%%): Additional Measurements 299 299 300 -(% style="color:red" %) **aMC1!- aMC9!**(%%) : Additional Measurements – Request CRC293 +**(% style="color:red" %)aMC1!- aMC9!**(%%) : Additional Measurements – Request CRC 301 301 302 302 303 303 * AT Command : AT+ADDRM=0,1,0,1 ... ... @@ -306,13 +306,13 @@ 306 306 307 307 Downlink:AA 01 aa bb cc dd 308 308 309 -(% style="color:#037691" %) **aa**(%%): SDI-12 sensor address.302 +**(% style="color:#037691" %)aa**(%%): SDI-12 sensor address. 310 310 311 -(% style="color:#037691" %) **bb**(%%): 0: no CRC, 1: request CRC304 +**(% style="color:#037691" %)bb**(%%): 0: no CRC, 1: request CRC 312 312 313 -(% style="color:#037691" %) **cc**(%%): 1-9: Additional Measurement, 0: no additional measurement306 +**(% style="color:#037691" %)cc**(%%): 1-9: Additional Measurement, 0: no additional measurement 314 314 315 -(% style="color:#037691" %) **dd**(%%): delay (in second) to send (% style="color:#037691" %)__**aD0!**__(%%) to get return.308 +**(% style="color:#037691" %)dd**(%%): delay (in second) to send **(% style="color:#037691" %)aD0!**(%%) to get return. 316 316 317 317 318 318 The following is the display information on the serial port and the server. ... ... @@ -325,16 +325,16 @@ 325 325 326 326 327 327 328 -==== (% style="color:blue" %) **aC!, aCC!, aC1!- aC9!, aCC1!- aCC9! **(%%)====321 +==== **(% style="color:blue" %)aC!, aCC!, aC1!- aC9!, aCC1!- aCC9! ** ==== 329 329 330 330 331 -(% style="color:red" %) **aC!**(%%) : Start Concurrent Measurement324 +**(% style="color:red" %)aC!**(%%) : Start Concurrent Measurement 332 332 333 -(% style="color:red" %) **aCC!** (%%): Start Concurrent Measurement – Request CRC326 +**(% style="color:red" %)aCC!** (%%): Start Concurrent Measurement – Request CRC 334 334 335 -(% style="color:red" %) **aC1!- aC9!**(%%) : Start Additional Concurrent Measurements328 +**(% style="color:red" %)aC1!- aC9!**(%%) : Start Additional Concurrent Measurements 336 336 337 -(% style="color:red" %) **aCC1!- aCC9!**(%%) : Start Additional Concurrent Measurements – Request CRC330 +**(% style="color:red" %)aCC1!- aCC9!**(%%) : Start Additional Concurrent Measurements – Request CRC 338 338 339 339 340 340 * AT Command : AT+ADDRC=0,1,0,1 ... ... @@ -343,13 +343,13 @@ 343 343 344 344 Downlink: AA 02 aa bb cc dd 345 345 346 -(% style="color:#037691" %) **aa**(%%): SDI-12 sensor address.339 +**(% style="color:#037691" %)aa**(%%): SDI-12 sensor address. 347 347 348 -(% style="color:#037691" %) **bb**(%%): 0: no CRC, 1: request CRC341 +**(% style="color:#037691" %)bb**(%%): 0: no CRC, 1: request CRC 349 349 350 -(% style="color:#037691" %) **cc**(%%): 1-9: Additional Measurement, 0: no additional measurement343 +**(% style="color:#037691" %)cc**(%%): 1-9: Additional Measurement, 0: no additional measurement 351 351 352 -(% style="color:#037691" %) **dd**(%%): delay (in second) to send (% style="color:#037691" %)__**aD0!**__(%%)____to get return.345 +**(% style="color:#037691" %)dd**(%%): delay (in second) to send **(% style="color:#037691" %)aD0!**(%%) to get return. 353 353 354 354 355 355 The following is the display information on the serial port and the server. ... ... @@ -363,7 +363,7 @@ 363 363 364 364 365 365 366 -==== (% style="color:blue" %) **aR0!- aR9!, aRC0!- aRC9!**(%%)====359 +==== **(% style="color:blue" %)aR0!- aR9!, aRC0!- aRC9!** ==== 367 367 368 368 369 369 Start Continuous Measurement ... ... @@ -376,18 +376,19 @@ 376 376 377 377 Downlink: AA 03 aa bb cc dd 378 378 379 -(% style="color:#037691" %) **aa**(%%): SDI-12 sensor address.372 +**(% style="color:#037691" %)aa**(%%): SDI-12 sensor address. 380 380 381 -(% style="color:#037691" %) **bb**(%%): 0: no CRC, 1: request CRC374 +**(% style="color:#037691" %)bb**(%%): 0: no CRC, 1: request CRC 382 382 383 -(% style="color:#037691" %) **cc**(%%): 1-9: Additional Measurement, 0: no additional measurement376 +**(% style="color:#037691" %)cc**(%%): 1-9: Additional Measurement, 0: no additional measurement 384 384 385 -(% style="color:#037691" %) **dd**(%%): delay (in second) to send (% style="color:#037691" %)__**aD0!**__(%%) to get return.378 +**(% style="color:#037691" %)dd**(%%): delay (in second) to send **(% style="color:#037691" %)aD0!**(%%) to get return. 386 386 387 387 388 388 The following is the display information on the serial port and the server. 389 389 390 390 384 + 391 391 [[image:image-20230201092208-14.png]] 392 392 393 393 ... ... @@ -402,20 +402,20 @@ 402 402 403 403 LoRaWAN Downlink: A8 aa xx xx xx xx bb cc 404 404 405 -(% style="color:#037691" %) **aa **(%%): total SDI-12 command length399 +**(% style="color:#037691" %)aa **(%%): total SDI-12 command length 406 406 407 -(% style="color:#037691" %) **xx **(%%): SDI-12 command401 +**(% style="color:#037691" %)xx **(%%): SDI-12 command 408 408 409 -(% style="color:#037691" %) **bb **(%%): Delay to wait for return403 +**(% style="color:#037691" %)bb **(%%): Delay to wait for return 410 410 411 -(% style="color:#037691" %) **cc **(%%): 0: don't uplink return to LoRaWAN, 1: Uplink return to LoRaWAN on FPORT=100405 +**(% style="color:#037691" %)cc **(%%): 0: don't uplink return to LoRaWAN, 1: Uplink return to LoRaWAN on FPORT=100 412 412 413 413 414 -(% style="color:blue" %) **Example: **(%%) AT+CFGDEV =0RC0!,1408 +**(% style="color:blue" %)Example: **(%%) AT+CFGDEV =0RC0!,1 415 415 416 -(% style="color:#037691" %) **0RC0! **(%%): SDI-12 Command,410 +**(% style="color:#037691" %)0RC0! **(%%): SDI-12 Command, 417 417 418 -(% style="color:#037691" %) **1 **(%%): Delay 1 second. ( 0: 810 mini-second)412 +**(% style="color:#037691" %)1 **(%%): Delay 1 second. ( 0: 810 mini-second) 419 419 420 420 Equal Downlink: 0xA8 05 30 52 43 30 21 01 01 421 421 ... ... @@ -437,7 +437,7 @@ 437 437 AT+CONVFORM ( Max length: 80 bytes) 438 438 439 439 440 -(% style="color:blue" %) **Example:**434 +**(% style="color:blue" %)Example:** 441 441 442 442 1) AT+CONVFORM=0, string Convert String from String to ASCII 443 443 ... ... @@ -457,31 +457,31 @@ 457 457 User can define max 15 SDI-12 Commands (AT+COMMAND1 ~~ AT+COMMANDF). On each uplink period (TDC time, default 20 minutes), SDI-12-LB will send these SDI-12 commands and wait for return from SDI-12 sensors. SDI-12-LB will then combine these returns and uplink via LoRaWAN. 458 458 459 459 460 -* (% style="color:blue" %) **AT Command:**454 +* ** (% style="color:blue" %)AT Command:** 461 461 462 -(% style="color:#037691" %) **AT+COMMANDx=var1,var2,var3,var4.**456 +**(% style="color:#037691" %)AT+COMMANDx=var1,var2,var3,var4.** 463 463 464 -(% style="color:red" %) **var1**(%%): SDI-12 command , for example: 0RC0!458 +**(% style="color:red" %)var1**(%%): SDI-12 command , for example: 0RC0! 465 465 466 -(% style="color:red" %) **var2**(%%): Wait timeout for return. (unit: second)460 +**(% style="color:red" %)var2**(%%): Wait timeout for return. (unit: second) 467 467 468 -(% style="color:red" %) **var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//.462 +**(% style="color:red" %)var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. 469 469 470 -(% style="color:red" %) **var4**(%%): validation check for return. If return invalid, SDI-12-LB will resend this command. Max 2 retries.464 +**(% style="color:red" %)var4**(%%): validation check for return. If return invalid, SDI-12-LB will resend this command. Max 2 retries. 471 471 472 -(% style="color:red" %) **0 **(%%) No validation check;466 +**(% style="color:red" %)0 **(%%) No validation check; 473 473 474 -(% style="color:red" %) **1**468 +**(% style="color:red" %)1** (%%) Check if return chars are printable char(0x20 ~~ 0x7E); 475 475 476 -(% style="color:red" %) **2**(%%) Check if there is return from SDI-12 sensor470 +**(% style="color:#red" %)2**(%%) Check if there is return from SDI-12 sensor 477 477 478 -(% style="color:red" %) **3**472 +**(% style="color:red" %)3** (%%) Check if return pass CRC check ( SDI-12 command var1 must include CRC request); 479 479 480 480 481 -Each AT+COMMANDx is followed by a (% style="color:blue" %) **AT+DATACUT**(%%) command. AT+DATACUT command is used to take the useful string from the SDI-12 sensor so the final payload will have the minimum length to uplink.475 +Each AT+COMMANDx is followed by a **(% style="color:blue" %)AT+DATACUT**(%%) command. AT+DATACUT command is used to take the useful string from the SDI-12 sensor so the final payload will have the minimum length to uplink. 482 482 483 483 484 -(% style="color:blue" %) **AT+DATACUTx**(%%) : This command defines how to handle the return from AT+COMMANDx, max return length is 100 bytes.478 +**(% style="color:blue" %)AT+DATACUTx**(%%) : This command defines how to handle the return from AT+COMMANDx, max return length is 100 bytes. 485 485 486 486 (% border="1" style="background-color:#f7faff; width:436px" %) 487 487 |(% style="width:433px" %)((( ... ... @@ -498,55 +498,54 @@ 498 498 499 499 500 500 (% border="1" cellspacing="4" style="background-color:#f7faff; width:510px" %) 501 -| =(% style="width:64px;" %)**AT+DATACUT1 value**|=(% style="width:44px;" %)**Final Result to combine Payload**502 -|(% style="width:1 64px" %)34,1,1+2+3|(% style="width:344px" %)0D 00 01 30 31 33503 -|(% style="width:1 64px" %)34,2,1~~8+12~~16|(% style="width:344px" %)0D 00 01 30 31 33 4D 45 54 45 52 54 45 52 31 32504 -|(% style="width:1 64px" %)34,2,1~~34|(% style="width:344px" %)0D 00 01 30 31 33 4D 45 54 45 52 20 20 20 54 45 52 31 32 20 31 31 32 54 31 32 2D 30 30 30 32 34 38 39 35 0D 0A495 +|(% style="width:170px" %)**AT+DATACUT1 value**|(% style="width:338px" %)**Final Result to combine Payload** 496 +|(% style="width:170px" %)34,1,1+2+3|(% style="width:338px" %)0D 00 01 30 31 33 497 +|(% style="width:170px" %)34,2,1~~8+12~~16|(% style="width:338px" %)0D 00 01 30 31 33 4D 45 54 45 52 54 45 52 31 32 498 +|(% style="width:170px" %)34,2,1~~34|(% style="width:338px" %)0D 00 01 30 31 33 4D 45 54 45 52 20 20 20 54 45 52 31 32 20 31 31 32 54 31 32 2D 30 30 30 32 34 38 39 35 0D 0A 505 505 506 -* (% style="color:blue" %) **Downlink Payload:**500 +* **(% style="color:blue" %) Downlink Payload:** 507 507 508 -(% style="color:blue" %) **0xAF**(%%) downlink command can be used to set AT+COMMANDx or AT+DATACUTx.502 +**(% style="color:blue" %)0xAF**(%%) downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 509 509 510 510 511 -(% style="color:red" %) **Note : if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.**505 +**(% style="color:red" %)Note : if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.** 512 512 513 513 514 -Format: ** (% style="color:#037691" %)AF MM NN LL XX XX XX XX YY (%%)**508 +Format: ** (% style="color:#037691" %)AF MM NN LL XX XX XX XX YY** 515 515 516 516 Where: 517 517 518 -* (% style="color:#037691" %) **MM **(%%): the AT+COMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,519 -* (% style="color:#037691" %) **NN **(%%): 1: set the AT+DATACUT value ; 2: set the AT+DATACUT value.520 -* (% style="color:#037691" %) **LL **(%%): The length of AT+COMMAND or AT+DATACUT command521 -* (% style="color:#037691" %) **XX XX XX XX **(%%): AT+COMMAND or AT+DATACUT command522 -* (% style="color:#037691" %) **YY **(%%): If YY=0, RS485-LN will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command.512 +* **(% style="color:#037691" %)MM **(%%): the AT+COMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 513 +* **(% style="color:#037691" %)NN **(%%): 1: set the AT+DATACUT value ; 2: set the AT+DATACUT value. 514 +* **(% style="color:#037691" %)LL **(%%): The length of AT+COMMAND or AT+DATACUT command 515 +* **(% style="color:#037691" %)XX XX XX XX **(%%): AT+COMMAND or AT+DATACUT command 516 +* **(% style="color:#037691" %)YY **(%%): If YY=0, RS485-LN will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command. 523 523 524 -(% style="color:blue" %) **Example:**518 +**(% style="color:blue" %)Example:** 525 525 526 526 [[image:image-20230201094129-18.png]] 527 527 528 528 523 +**(% style="color:blue" %)Clear SDI12 Command** 529 529 530 -(% style="color:blue" %)**Clear SDI12 Command** 531 - 532 532 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 533 533 534 534 535 -* (% style="color:#037691" %) **AT Command:**528 +* ** (% style="color:#037691" %)AT Command:** 536 536 537 -(% style="color:#4 f81bd" %)**AT+CMDEAR=mm,nn**530 +**(% style="color:#4F81BD" %)AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase 538 538 539 539 540 540 Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 541 541 542 542 543 -* (% style="color:#037691" %) **Downlink Payload:**536 +* **(% style="color:#037691" %) Downlink Payload:** 544 544 545 -(% style="color:#4 f81bd" %)**0x09 aa bb**(%%) same as AT+CMDEAR=aa,bb538 +**(% style="color:#4F81BD" %)0x09 aa bb**(%%) same as AT+CMDEAR=aa,bb 546 546 547 547 548 548 549 -(% style="color:blue" %) **command combination**542 +**(% style="color:blue" %)command combination** 550 550 551 551 Below shows a screen shot how the results combines together to a uplink payload. 552 552 ... ... @@ -555,27 +555,28 @@ 555 555 556 556 If user don't want to use DATACUT for some command, he simply want to uplink all returns. AT+ALLDATAMOD can be set to 1. 557 557 558 -(% style="color:blue" %) **AT+ALLDATAMOD**(%%) will simply get all return and don't do CRC check as result for SDI-12 command. AT+DATACUTx command has higher priority, if AT+DATACUTx has been set, AT+ALLDATAMOD will be ignore for this SDI-12 command.551 +**(% style="color:blue" %)AT+ALLDATAMOD**(%%) will simply get all return and don't do CRC check as result for SDI-12 command. AT+DATACUTx command has higher priority, if AT+DATACUTx has been set, AT+ALLDATAMOD will be ignore for this SDI-12 command. 559 559 560 560 561 -(% style="color:#4 f81bd" %)**For example: **(%%)as below photo, AT+ALLDATAMOD=1, but AT+DATACUT1 has been set, AT+DATACUT1 will be still effect the result.554 +**(% style="color:#4F81BD" %)For example: ** as below photo, AT+ALLDATAMOD=1, but AT+DATACUT1 has been set, AT+DATACUT1 will be still effect the result. 562 562 563 563 564 564 [[image:1675215782925-448.png]] 565 565 566 566 567 -If AT+ALLDATAMOD=1, (% style="color:#4 f81bd" %)**FX,X**(%%) will be added in the payload, FX specify which command is used and X specify the length of return. for example in above screen, F1 05 means the return is from AT+COMMAND1 and the return is 5 bytes.560 +If AT+ALLDATAMOD=1, **(% style="color:#4F81BD" %)FX,X**(%%) will be added in the payload, FX specify which command is used and X specify the length of return. for example in above screen, F1 05 means the return is from AT+COMMAND1 and the return is 5 bytes. 568 568 569 569 570 570 571 -(% style="color:blue" %) **Compose Uplink**564 +**(% style="color:blue" %)Compose Uplink** 572 572 573 -(% style="color:#4f81bd" %)**AT+DATAUP=0** 574 574 575 - Composethe uplink payload with valuereturnsin sequence and send with **__ASIGNLEUPLINK__**.567 +**(% style="color:#4F81BD" %)AT+DATAUP=0** 576 576 577 - FinalPayload is **__BatteryInfo+PAYVER + VALID ValuefromRETURN1+ValidValuefromRETURN2+ … + RETURNx__**569 +Compose the uplink payload with value returns in sequence and send with A SIGNLE UPLINK. 578 578 571 +Final Payload is Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx 572 + 579 579 Where PAYVER is defined by AT+PAYVER, below is an example screen shot. 580 580 581 581 ... ... @@ -582,12 +582,14 @@ 582 582 [[image:1675215828102-844.png]] 583 583 584 584 585 -(% style="color:#4 f81bd" %)**AT+DATAUP=1**579 +**(% style="color:#4F81BD" %)AT+DATAUP=1** 586 586 587 -Compose the uplink payload with value returns in sequence and send with **__Multiply UPLINKs__**.581 +Compose the uplink payload with value returns in sequence and send with Multiply UPLINKs. 588 588 589 -Final Payload is __**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**__583 +Final Payload is 590 590 585 +__**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**__ 586 + 591 591 1. Battery Info (2 bytes): Battery voltage 592 592 1. PAYVER (1 byte): Defined by AT+PAYVER 593 593 1. PAYLOAD COUNT (1 byte): Total how many uplinks of this sampling. ... ... @@ -597,7 +597,7 @@ 597 597 [[image:1675215848113-696.png]] 598 598 599 599 600 -(% style="color:red" %) **Notice: the Max bytes is according to the max support bytes in different Frequency Bands for lowest SF. As below:**596 +**(% style="color:red" %)Notice: the Max bytes is according to the max support bytes in different Frequency Bands for lowest SF. As below:** 601 601 602 602 * For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink ( so 51 -5 = 46 max valid date) 603 603 * For AU915/AS923 bands, if UplinkDwell time=1, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date). ... ... @@ -604,12 +604,12 @@ 604 604 * For US915 band, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date). 605 605 * For all other bands: max 51 bytes for each uplink ( so 51 -5 = 46 max valid date). 606 606 607 -(% style="color:red" %) **When AT+DATAUP=1, the maximum number of segments is 15, and the maximum total number of bytes is 1500;**603 +**(% style="color:red" %)When AT+DATAUP=1, the maximum number of segments is 15, and the maximum total number of bytes is 1500;** 608 608 609 -(% style="color:red" %) **When AT+DATAUP=1 and AT+ADR=0, the maximum number of bytes of each payload is determined by the DR value.**605 +**(% style="color:red" %)When AT+DATAUP=1 and AT+ADR=0, the maximum number of bytes of each payload is determined by the DR value.** 610 610 611 611 612 -== 2.4 Uplink Payload == 608 +== 2.4 Uplink Payload == 613 613 614 614 615 615 Uplink payloads have two types: ... ... @@ -627,10 +627,10 @@ 627 627 628 628 Users can also use the downlink command(0x26 01) to ask SDI-12-LB to resend this uplink. 629 629 630 -(% border="1" cellspacing="4" style="background-color:#f7faff; width:4 20px" %)626 +(% border="1" cellspacing="4" style="background-color:#f7faff; width:437px" %) 631 631 |(% colspan="6" style="width:434px" %)**Device Status (FPORT=5)** 632 -|(% style="width:1 14px" %)**Size(bytes)**|(% style="width:39px" %)**1**|(% style="width:80px" %)**2**|(% style="width:89px" %)**1**|(% style="width:59px" %)**1**|(% style="width:37px" %)**2**633 -|(% style="width:1 14px" %)**Value**|(% style="width:39px" %)Sensor Model|(% style="width:80px" %)Firmware Version|(% style="width:89px" %)Frequency Band|(% style="width:59px" %)Sub-band|(% style="width:37px" %)BAT628 +|(% style="width:102px" %)**Size (bytes)**|(% style="width:67px" %)**1**|(% style="width:80px" %)**2**|(% style="width:89px" %)**1**|(% style="width:52px" %)**1**|(% style="width:44px" %)**2** 629 +|(% style="width:102px" %)**Value**|(% style="width:67px" %)Sensor Model|(% style="width:80px" %)Firmware Version|(% style="width:89px" %)Frequency Band|(% style="width:52px" %)Sub-band|(% style="width:44px" %)BAT 634 634 635 635 Example parse in TTNv3 636 636 ... ... @@ -637,11 +637,11 @@ 637 637 [[image:1675215946738-635.png]] 638 638 639 639 640 -(% style="color:#037691" %) **Sensor Model**(%%): For SDI-12-LB, this value is 0x17636 +**(% style="color:#037691" %)Sensor Model**(%%): For SDI-12-LB, this value is 0x17 641 641 642 -(% style="color:#037691" %) **Firmware Version**(%%): 0x0100, Means: v1.0.0 version638 +**(% style="color:#037691" %)Firmware Version**(%%): 0x0100, Means: v1.0.0 version 643 643 644 -(% style="color:#037691" %) **Frequency Band**:640 +**(% style="color:#037691" %)Frequency Band**: 645 645 646 646 *0x01: EU868 647 647 ... ... @@ -672,7 +672,7 @@ 672 672 *0x0e: MA869 673 673 674 674 675 -(% style="color:#037691" %) **Sub-Band**:671 +**(% style="color:#037691" %)Sub-Band**: 676 676 677 677 AU915 and US915:value 0x00 ~~ 0x08 678 678 ... ... @@ -681,7 +681,7 @@ 681 681 Other Bands: Always 0x00 682 682 683 683 684 -(% style="color:#037691" %) **Battery Info**:680 +**(% style="color:#037691" %)Battery Info**: 685 685 686 686 Check the battery voltage. 687 687 ... ... @@ -699,15 +699,15 @@ 699 699 700 700 * Periodically Uplink: FPORT=2 701 701 702 -(% border="1" cellspacing="4" style="background-color:#f7faff; width:50 0px" %)703 -| =(% style="width:0px;" %)(((698 +(% border="1" cellspacing="4" style="background-color:#f7faff; width:510px" %) 699 +|(% style="width:93px" %)((( 704 704 **Size(bytes)** 705 -)))| =(% style="width:0px;" %)**2**|=(% style="width:90px;" %)**1**|=(% style="width:0px;" %)**Length depends on the return from the commands**701 +)))|(% style="width:83px" %)**2**|(% style="width:70px" %)**1**|(% style="width:234px" %)**Length depends on the return from the commands** 706 706 |(% style="width:93px" %)**Value**|(% style="width:83px" %)((( 707 707 Battery(mV) 708 708 & 709 709 Interrupt_Flag 710 -)))|(% style="width: 91px" %)[[PAYLOAD_VER>>||anchor="H3.6Setthepayloadversion"]]|(% style="width:212px" %)(((706 +)))|(% style="width:70px" %)[[PAYLOAD_VER>>||anchor="H3.6Setthepayloadversion"]]|(% style="width:234px" %)((( 711 711 If the valid payload is too long and exceed the maximum support. 712 712 Payload length in server,server will show payload not provided in the LoRaWAN server. 713 713 ))) ... ... @@ -728,7 +728,7 @@ 728 728 === 2.4.4 Interrupt Pin === 729 729 730 730 731 -This data field shows if this packet is generated by (% style="color:#037691" %) **Interrupt Pin**(%%) or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up. Note: The Internet Pin is a separate pin in the screw terminal. See [[pin mapping>>||anchor="H1.7PinMapping"]].727 +This data field shows if this packet is generated by **(% style="color:#037691" %)Interrupt Pin**(%%) or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up. Note: The Internet Pin is a separate pin in the screw terminal. See [[pin mapping>>||anchor="H1.7PinMapping"]]. 732 732 733 733 **Example:** 734 734 ... ... @@ -759,9 +759,11 @@ 759 759 760 760 The SDI-12-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: 761 761 762 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]] ]]758 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]] 763 763 764 764 761 + 762 + 765 765 == 2.6 Frequency Plans == 766 766 767 767 ... ... @@ -770,12 +770,13 @@ 770 770 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 771 771 772 772 771 + 773 773 == 2.7 Firmware Change Log == 774 774 775 775 776 776 **Firmware download link:** 777 777 778 -[[https:~~/~~/www.dropbox.com/sh/ qrbgbikb109lkiv/AACBR-v_ZhZAMengcY7Nsa1ja?dl=0>>https://www.dropbox.com/sh/qrbgbikb109lkiv/AACBR-v_ZhZAMengcY7Nsa1ja?dl=0]]777 +[[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]] 779 779 780 780 781 781 = 3. Configure SDI-12-LB via AT Command or LoRaWAN Downlink = ... ... @@ -783,12 +783,12 @@ 783 783 784 784 Use can configure SDI-12-LB via AT Command or LoRaWAN Downlink. 785 785 786 -* AT Command Connection: See [[FAQ>> ||anchor="H7.FAQ"]].785 +* AT Command Connection: See [[FAQ>>path:#AT_COMMAND]]. 787 787 * LoRaWAN Downlink instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 788 788 789 789 There are two kinds of commands to configure SDI-12-LB, they are: 790 790 791 -* (% style="color:blue" %)**General Commands**.790 +* **General Commands**. 792 792 793 793 These commands are to configure: 794 794 ... ... @@ -797,10 +797,10 @@ 797 797 798 798 They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 799 799 800 -[[http:~~/~~/wiki.dragino.com/ xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]799 +[[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_Downlink_Command>>url:http://wiki.dragino.com/index.php?title=End_Device_Downlink_Command]] 801 801 802 802 803 -* (% style="color:blue" %)**Commands special design for SDI-12-LB**802 +* **Commands special design for SDI-12-LB** 804 804 805 805 These commands only valid for SDI-12-LB, as below: 806 806 ... ... @@ -834,8 +834,6 @@ 834 834 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 835 835 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 836 836 837 - 838 - 839 839 == 3.2 Set Interrupt Mode == 840 840 841 841 ... ... @@ -867,8 +867,6 @@ 867 867 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 868 868 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 869 869 870 - 871 - 872 872 == 3.3 Set the output time == 873 873 874 874 ... ... @@ -938,8 +938,6 @@ 938 938 * Example 5: Downlink Payload: 070301F4 **~-~-->** AT+12VT=500 939 939 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 940 940 941 - 942 - 943 943 == 3.4 Set the all data mode == 944 944 945 945 ... ... @@ -962,8 +962,6 @@ 962 962 * Example 1: Downlink Payload: AB 00 ~/~/ AT+ALLDATAMOD=0 963 963 * Example 2: Downlink Payload: AB 01 ~/~/ AT+ALLDATAMOD=1 964 964 965 - 966 - 967 967 == 3.5 Set the splicing payload for uplink == 968 968 969 969 ... ... @@ -1000,7 +1000,6 @@ 1000 1000 1001 1001 == 3.6 Set the payload version == 1002 1002 1003 - 1004 1004 Feature, Set the payload version. 1005 1005 1006 1006 (% style="color:blue" %)**AT Command: AT+PAYVER** ... ... @@ -1020,8 +1020,6 @@ 1020 1020 * Example 1: Downlink Payload: AE 01 ~/~/ AT+PAYVER=1 1021 1021 * Example 2: Downlink Payload: AE 05 ~/~/ AT+PAYVER=5 1022 1022 1023 - 1024 - 1025 1025 = 4. Battery & how to replace = 1026 1026 1027 1027 == 4.1 Battery Type == ... ... @@ -1032,7 +1032,7 @@ 1032 1032 1033 1033 The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance. 1034 1034 1035 -[[image:1675 234124233-857.png]]1023 +[[image:1675146710956-626.png]] 1036 1036 1037 1037 1038 1038 Minimum Working Voltage for the SDI-12-LB: ... ... @@ -1065,10 +1065,9 @@ 1065 1065 1066 1066 And the Life expectation in difference case will be shown on the right. 1067 1067 1056 +[[image:1675146895108-304.png]] 1068 1068 1069 -[[image:1675234155374-163.png]] 1070 1070 1071 - 1072 1072 The battery related documents as below: 1073 1073 1074 1074 * [[Battery Dimension>>https://www.dropbox.com/s/ox5g9njwjle7aw3/LSN50-Battery-Dimension.pdf?dl=0]], ... ... @@ -1075,7 +1075,7 @@ 1075 1075 * [[Lithium-Thionyl Chloride Battery datasheet, Tech Spec>>https://www.dropbox.com/sh/d4oyfnp8o94180o/AABQewCNSh5GPeQH86UxRgQQa?dl=0]] 1076 1076 * [[Lithium-ion Battery-Capacitor datasheet>>https://www.dropbox.com/s/791gjes2lcbfi1p/SPC_1520_datasheet.jpg?dl=0]], [[Tech Spec>>https://www.dropbox.com/s/4pkepr9qqqvtzf2/SPC1520%20Technical%20Specification20171123.pdf?dl=0]] 1077 1077 1078 -[[image:image-20230 201145019-19.png]]1065 +[[image:image-20230131145708-3.png]] 1079 1079 1080 1080 1081 1081 === 4.3.1 Battery Note === ... ... @@ -1092,6 +1092,7 @@ 1092 1092 The default battery pack of SDI-12-LB includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 1093 1093 1094 1094 1082 + 1095 1095 = 5. Remote Configure device = 1096 1096 1097 1097 == 5.1 Connect via BLE == ... ... @@ -1112,58 +1112,36 @@ 1112 1112 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 1113 1113 1114 1114 1115 -= 7. FAQ = 1116 1116 1117 -= =7.1How to useAT Command toaccess device?==1104 += 7. Order Info = 1118 1118 1119 1119 1120 -See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]] 1107 +Part Number: SDI-12-LB-XXX 1108 +XXX: The default frequency band 1121 1121 1110 +AS923: LoRaWAN AS923 band 1111 +AU915: LoRaWAN AU915 band 1112 +EU433: LoRaWAN EU433 band 1113 +EU868: LoRaWAN EU868 band 1114 +KR920: LoRaWAN KR920 band 1115 +US915: LoRaWAN US915 band 1116 +IN865: LoRaWAN IN865 band 1117 +CN470: LoRaWAN CN470 band 1122 1122 1123 -== 7.2 How to update firmware via UART port? == 1124 1124 1125 1125 1126 -See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]] 1127 1127 1128 1128 1129 -== 7.3 How to change the LoRa Frequency Bands/Region? == 1130 1130 1131 1131 1132 -You can follow the instructions for [[how to upgrade image>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]. 1133 -When downloading the images, choose the required image file for download. 1125 += 8. Packing Info = 1134 1134 1135 1135 1136 - = 8. OrderInfo =1128 +**Package Includes**: 1137 1137 1138 - 1139 -((( 1140 -(% style="color:blue" %)**Part Number: SDI-12-LB-XXX** 1141 -))) 1142 - 1143 -((( 1144 -XXX: The default frequency band 1145 -))) 1146 - 1147 -((( 1148 -(% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 1149 -(% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band 1150 -(% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band 1151 -(% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band 1152 -(% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band 1153 -(% style="color:red" %)**US915**(%%): LoRaWAN US915 band 1154 -(% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1155 -(% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1156 -))) 1157 - 1158 - 1159 -= 9. Packing Info = 1160 - 1161 - 1162 -(% style="color:#037691" %)**Package Includes**: 1163 - 1164 1164 * SDI-12-LB SDI-12 to LoRaWAN Converter x 1 1165 1165 1166 - (% style="color:#037691" %)**Dimension and weight**:1132 +**Dimension and weight**: 1167 1167 1168 1168 * Device Size: cm 1169 1169 * Device Weight: g ... ... @@ -1170,11 +1170,9 @@ 1170 1170 * Package Size / pcs : cm 1171 1171 * Weight / pcs : g 1172 1172 1139 += 9. Support = 1173 1173 1174 1174 1175 -= 10. Support = 1176 - 1177 - 1178 1178 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1179 1179 1180 1180 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
- 1675234155374-163.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -138.2 KB - Content
- image-20230201145019-19.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -82.2 KB - Content
- image-20230201152430-20.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -16.5 KB - Content