Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Mengting Qiu on 2025/07/03 15:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -38,6 +38,8 @@ 38 38 [[image:image-20230201084414-1.png||height="464" width="1108"]] 39 39 40 40 41 + 42 + 41 41 == 1.2 Features == 42 42 43 43 ... ... @@ -295,7 +295,7 @@ 295 295 296 296 (% style="color:#037691" %)**cc**(%%): 1-9: Additional Measurement, 0: no additional measurement 297 297 298 -(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %) __**aD0!**__(%%) to get return.300 +(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)**aD0!**(%%) to get return. 299 299 300 300 301 301 The following is the display information on the serial port and the server. ... ... @@ -332,7 +332,7 @@ 332 332 333 333 (% style="color:#037691" %)**cc**(%%): 1-9: Additional Measurement, 0: no additional measurement 334 334 335 -(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %) __**aD0!**__(%%)____to get return.337 +(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)**aD0!**(%%) to get return. 336 336 337 337 338 338 The following is the display information on the serial port and the server. ... ... @@ -365,12 +365,13 @@ 365 365 366 366 (% style="color:#037691" %)**cc**(%%): 1-9: Additional Measurement, 0: no additional measurement 367 367 368 -(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %) __**aD0!**__(%%) to get return.370 +(% style="color:#037691" %)**dd**(%%): delay (in second) to send (% style="color:#037691" %)**aD0!**(%%) to get return. 369 369 370 370 371 371 The following is the display information on the serial port and the server. 372 372 373 373 376 + 374 374 [[image:image-20230201092208-14.png]] 375 375 376 376 ... ... @@ -456,7 +456,7 @@ 456 456 457 457 (% style="color:red" %)**1** (%%) Check if return chars are printable char(0x20 ~~ 0x7E); 458 458 459 -(% style="color:red" %)**2**(%%) Check if there is return from SDI-12 sensor 462 +(% style="color:#red" %)**2**(%%) Check if there is return from SDI-12 sensor 460 460 461 461 (% style="color:red" %)**3** (%%) Check if return pass CRC check ( SDI-12 command var1 must include CRC request); 462 462 ... ... @@ -540,7 +540,7 @@ 540 540 (% style="color:blue" %)**AT+ALLDATAMOD**(%%) will simply get all return and don't do CRC check as result for SDI-12 command. AT+DATACUTx command has higher priority, if AT+DATACUTx has been set, AT+ALLDATAMOD will be ignore for this SDI-12 command. 541 541 542 542 543 -(% style="color:#4f81bd" %)**For example: ** (%%)as below photo, AT+ALLDATAMOD=1, but AT+DATACUT1 has been set, AT+DATACUT1 will be still effect the result.546 +(% style="color:#4f81bd" %)**For example: ** as below photo, AT+ALLDATAMOD=1, but AT+DATACUT1 has been set, AT+DATACUT1 will be still effect the result. 544 544 545 545 546 546 [[image:1675215782925-448.png]] ... ... @@ -555,9 +555,9 @@ 555 555 556 556 (% style="color:#4f81bd" %)**AT+DATAUP=0** 557 557 558 -Compose the uplink payload with value returns in sequence and send with **__A SIGNLE UPLINK__**.561 +Compose the uplink payload with value returns in sequence and send with A SIGNLE UPLINK. 559 559 560 -Final Payload is **__Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx__**563 +Final Payload is Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx 561 561 562 562 Where PAYVER is defined by AT+PAYVER, below is an example screen shot. 563 563 ... ... @@ -567,10 +567,12 @@ 567 567 568 568 (% style="color:#4f81bd" %)**AT+DATAUP=1** 569 569 570 -Compose the uplink payload with value returns in sequence and send with **__Multiply UPLINKs__**.573 +Compose the uplink payload with value returns in sequence and send with Multiply UPLINKs. 571 571 572 -Final Payload is __**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**__575 +Final Payload is 573 573 577 +__**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**__ 578 + 574 574 1. Battery Info (2 bytes): Battery voltage 575 575 1. PAYVER (1 byte): Defined by AT+PAYVER 576 576 1. PAYLOAD COUNT (1 byte): Total how many uplinks of this sampling. ... ... @@ -745,6 +745,8 @@ 745 745 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]]] 746 746 747 747 753 + 754 + 748 748 == 2.6 Frequency Plans == 749 749 750 750 ... ... @@ -758,9 +758,8 @@ 758 758 759 759 **Firmware download link:** 760 760 761 -[[https:~~/~~/www.dropbox.com/sh/ qrbgbikb109lkiv/AACBR-v_ZhZAMengcY7Nsa1ja?dl=0>>https://www.dropbox.com/sh/qrbgbikb109lkiv/AACBR-v_ZhZAMengcY7Nsa1ja?dl=0]]768 +[[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]] 762 762 763 - 764 764 765 765 = 3. Configure SDI-12-LB via AT Command or LoRaWAN Downlink = 766 766 ... ... @@ -1123,6 +1123,11 @@ 1123 1123 (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1124 1124 1125 1125 1132 + 1133 + 1134 + 1135 + 1136 + 1126 1126 = 9. Packing Info = 1127 1127 1128 1128