<
From version < 40.2 >
edited by Xiaoling
on 2023/02/01 14:50
To version < 40.8 >
edited by Xiaoling
on 2023/02/01 15:00
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -17,7 +17,6 @@
17 17  
18 18  
19 19  
20 -
21 21  = 1. Introduction =
22 22  
23 23  == 1.1 ​What is SDI-12 to LoRaWAN Converter ==
... ... @@ -602,7 +602,7 @@
602 602  (% style="color:red" %)**When AT+DATAUP=1 and AT+ADR=0, the maximum number of bytes of each payload is determined by the DR value.**
603 603  
604 604  
605 -== ​​​​​​​2.4 Uplink Payload ==
604 +== 2.4 Uplink Payload ==
606 606  
607 607  
608 608  Uplink payloads have two types:
... ... @@ -765,7 +765,6 @@
765 765  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
766 766  
767 767  
768 -
769 769  == 2.7 Firmware Change Log ==
770 770  
771 771  
... ... @@ -779,12 +779,12 @@
779 779  
780 780  Use can configure SDI-12-LB via AT Command or LoRaWAN Downlink.
781 781  
782 -* AT Command Connection: See [[FAQ>>path:#AT_COMMAND]].
780 +* AT Command Connection: See [[FAQ>>||anchor="H7.FAQ"]].
783 783  * LoRaWAN Downlink instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
784 784  
785 785  There are two kinds of commands to configure SDI-12-LB, they are:
786 786  
787 -* **General Commands**.
785 +* (% style="color:blue" %)**General Commands**.
788 788  
789 789  These commands are to configure:
790 790  
... ... @@ -796,7 +796,7 @@
796 796  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
797 797  
798 798  
799 -* **Commands special design for SDI-12-LB**
797 +* (% style="color:blue" %)**Commands special design for SDI-12-LB**
800 800  
801 801  These commands only valid for SDI-12-LB, as below:
802 802  
... ... @@ -830,6 +830,8 @@
830 830  * Example 1: Downlink Payload: 0100001E  ~/~/ Set Transmit Interval (TDC) = 30 seconds
831 831  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
832 832  
831 +
832 +
833 833  == 3.2 Set Interrupt Mode ==
834 834  
835 835  
... ... @@ -861,6 +861,8 @@
861 861  * Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
862 862  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
863 863  
864 +
865 +
864 864  == 3.3 Set the output time ==
865 865  
866 866  
... ... @@ -930,6 +930,8 @@
930 930  * Example 5: Downlink Payload: 070301F4  **~-~-->**  AT+12VT=500
931 931  * Example 6: Downlink Payload: 07030000  **~-~-->**  AT+12VT=0
932 932  
935 +
936 +
933 933  == 3.4 Set the all data mode ==
934 934  
935 935  
... ... @@ -952,6 +952,8 @@
952 952  * Example 1: Downlink Payload: AB 00  ~/~/  AT+ALLDATAMOD=0
953 953  * Example 2: Downlink Payload: AB 01  ~/~/  AT+ALLDATAMOD=1
954 954  
959 +
960 +
955 955  == 3.5 Set the splicing payload for uplink ==
956 956  
957 957  
... ... @@ -1007,6 +1007,8 @@
1007 1007  * Example 1: Downlink Payload: AE 01  ~/~/  AT+PAYVER=1
1008 1008  * Example 2: Downlink Payload: AE 05  ~/~/  AT+PAYVER=5
1009 1009  
1016 +
1017 +
1010 1010  = 4. Battery & how to replace =
1011 1011  
1012 1012  == 4.1 Battery Type ==
... ... @@ -1060,7 +1060,6 @@
1060 1060  * [[Lithium-Thionyl Chloride Battery datasheet, Tech Spec>>https://www.dropbox.com/sh/d4oyfnp8o94180o/AABQewCNSh5GPeQH86UxRgQQa?dl=0]]
1061 1061  * [[Lithium-ion Battery-Capacitor datasheet>>https://www.dropbox.com/s/791gjes2lcbfi1p/SPC_1520_datasheet.jpg?dl=0]], [[Tech Spec>>https://www.dropbox.com/s/4pkepr9qqqvtzf2/SPC1520%20Technical%20Specification20171123.pdf?dl=0]]
1062 1062  
1063 -
1064 1064  [[image:image-20230201145019-19.png]]
1065 1065  
1066 1066  
... ... @@ -1078,7 +1078,6 @@
1078 1078  The default battery pack of SDI-12-LB includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1079 1079  
1080 1080  
1081 -
1082 1082  = 5. Remote Configure device =
1083 1083  
1084 1084  == 5.1 Connect via BLE ==
... ... @@ -1123,17 +1123,18 @@
1123 1123  = 8. ​Order Info =
1124 1124  
1125 1125  
1126 -Part Number: SDI-12-LB-XXX
1132 +(% style="color:blue" %)**Part Number: SDI-12-LB-XXX**
1133 +
1127 1127  XXX: The default frequency band
1128 1128  
1129 -AS923: LoRaWAN AS923 band
1130 -AU915: LoRaWAN AU915 band
1131 -EU433: LoRaWAN EU433 band
1132 -EU868: LoRaWAN EU868 band
1133 -KR920: LoRaWAN KR920 band
1134 -US915: LoRaWAN US915 band
1135 -IN865: LoRaWAN IN865 band
1136 -CN470: LoRaWAN CN470 band
1136 +(% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band
1137 +(% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band
1138 +(% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band
1139 +(% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band
1140 +(% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band
1141 +(% style="color:red" %)**US915**(%%): LoRaWAN US915 band
1142 +(% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band
1143 +(% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1137 1137  
1138 1138  
1139 1139  
... ... @@ -1144,11 +1144,11 @@
1144 1144  = 9. Packing Info =
1145 1145  
1146 1146  
1147 -**Package Includes**:
1154 +(% style="color:#037691" %)**Package Includes**:
1148 1148  
1149 1149  * SDI-12-LB SDI-12 to LoRaWAN Converter x 1
1150 1150  
1151 -**Dimension and weight**:
1158 +(% style="color:#037691" %)**Dimension and weight**:
1152 1152  
1153 1153  * Device Size: cm
1154 1154  * Device Weight: g
... ... @@ -1155,6 +1155,8 @@
1155 1155  * Package Size / pcs : cm
1156 1156  * Weight / pcs : g
1157 1157  
1165 +
1166 +
1158 1158  = 10. ​Support =
1159 1159  
1160 1160  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0